Summary
International Symposium on Electromagnetic Compatibility
2009
Session Number:23S2
Session:
Number:23S2-3
Static Magnetic Field Disturbance near Water - Water Nuclear Reactor Core at Attainment of Power
V. P. Goncharov,
pp.623-624
Publication Date:2009/7/20
Online ISSN:2188-5079
DOI:10.34385/proc.14.23S2-3
PDF download (359.9KB)
Summary:
In the course of works on research of electromagnetic conditions in a physical hall of a water-water nuclear reactor an increment of a static magnetic field was revealed at a rise of reactor power in the area adjacent to an active zone. The maximal value of the increment amounted to 0.012 A/m on reaching 2500 kW power and 0.065 A/m on reaching 7000 kW (measurements are conducted on two different reactors). Key words: nuclear reactor, nuclear power, active zone, magnetic field, magnetic field sensor, magnetic field disturbance.