2016-01-21 14:15 |
Tokyo |
|
Depth Estimation in Magnetic Particle Imaging Using Two Pickup Coils Manabu Morishita, Yuya Tsujita, Msahiro Muta, Teruyoshi sasayama, Takashi Yoshida, Masaaki Matsuo, Keiji Enpuku (Kyushu Univ.) SCE2015-44 |
MPI (Magnetic Particle Imaging) is a method to image magnetic nanoparticles accumulated in human body, and is expected f... [more] |
SCE2015-44 pp.47-52 |
SCE |
2013-01-24 15:25 |
Okayama |
Okayama Univ. |
High Sensitivity Measurement of AC magnetic Field for Magnetic Particle Imaging Takuro Mihaya, Takafumi Morishige, Takashi Yoshida, Keiji Enpuku (Kyushu Univ.) SCE2012-37 |
MPI (Magnetic Particle Imaging) is a method to image magnetic nanoparticles accumulate in the human body, and is expecte... [more] |
SCE2012-37 pp.69-74 |
SCE |
2012-01-26 13:55 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. B3-2 |
Cooled Cu Pickup Coil Coupled to HTS SQUID for High Sensitive Measurement of AC Magnetic Field Ryuji Momotomi, Takuro Mihaya, Masaaki Matsuo, Takashi Yoshida, Keiji Enpuku (Kyushu Univ.) SCE2011-24 |
We studied the performance of Cu pickup coil cooled at T = 77 K for high sensitive measurement of ac magnetic field. The... [more] |
SCE2011-24 pp.29-34 |
SCE |
2011-01-24 14:45 |
Tokyo |
Kikai-Shinko-Kaikan Bldg |
Performance of Magnetometer Utilizing Resonance type Pickup Coil and SQUID Shintaro Hirakawa, Ryuji Momotomi, Masaaki Matsuo, Keiji Enpuku (Kyushu Univ.), Akihiko Kandori (Hitachi) SCE2010-45 |
We have designed and tested an HTS SQUID magnetometer using resonant coupling of copper pickup coil cooled at T=77 K. Th... [more] |
SCE2010-45 pp.51-56 |
SCE |
2010-01-20 13:50 |
Tokyo |
Kikai-Shinkou-Kaikan Bldg. |
Performance of HTS SQUID coupled to cooled-Cu/Superconducting pickup coil Yusuke Tsuji, Shintaro Hirakawa, Ryuji Momotomi, Masaaki Matsuo, Keiji Enpuku (Kyushu Univ.) SCE2009-29 |
We studied the performance of the magnetometer made of a high Tc SQUID. The SQUID was magnetically coupled to a cooled C... [more] |
SCE2009-29 pp.27-32 |
SCE |
2006-07-06 13:45 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
NDE System Utilizing SQUID Picovoltmeter and Cooled Normal Pickup Coil Daiske Yamasaki, Kazuya Tazho, Keiji Enpuku (Kyushu Univ.) |
Nondestructive evaluation (NDE) system utilizing a cooled normal pickup coil and a high-Tc superconducting quantum inter... [more] |
SCE2006-20 pp.41-46 |
|
|
|
Copyright and reproduction :
All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034)
|