Summary
International Symposium on Electromagnetic Compatibility
2009
Session Number:21S1
Session:
Number:21S1-7
SAR Probe Calibration: the Results of an Inter-Comparison Study
B. G Loader,
pp.81-83
Publication Date:2009/7/20
Online ISSN:2188-5079
DOI:10.34385/proc.14.21S1-7
PDF download (189.9KB)
Summary:
This paper gives the results of an intercomparison of the calibration results for four specific absorption rate (SAR) probes as measured by three independent laboratories. The artefact standards used for the calibration were matched waveguide cells that generate a calculable SAR level in a liquid phantom, and these systems are described, together with the measurement uncertainties. The results were found to be consistent with the quoted measurement uncertainties of the laboratories.