Presentation 2014-03-13
Citizen's Failure Analysis of the Fukushima Dai Ichi Unit. 1 : Meltdown Caused by Automatic Safety Operations
Noboru KUSAMA,
PDF Download Page PDF download Page Link
Abstract(in Japanese) (See Japanese page)
Abstract(in English) This paper describes a possible reason for the meltdown in Fukushima Daiichi nuclear power plant Unit 1. The operation of IC, instead of HPCI which is specified by the manual, probably caused the meltdown.
Keyword(in Japanese) (See Japanese page)
Keyword(in English) Fukushima Dai ichi / Isolation Condenser / HPCI / Turuga Unit. 1 / Reactor Water Level / Safety Operation
Paper # SSS2013-34
Date of Issue

Conference Information
Committee SSS
Conference Date 2014/3/6(1days)
Place (in Japanese) (See Japanese page)
Place (in English)
Topics (in Japanese) (See Japanese page)
Topics (in English)
Chair
Vice Chair
Secretary
Assistant

Paper Information
Registration To Safety (SSS)
Language JPN
Title (in Japanese) (See Japanese page)
Sub Title (in Japanese) (See Japanese page)
Title (in English) Citizen's Failure Analysis of the Fukushima Dai Ichi Unit. 1 : Meltdown Caused by Automatic Safety Operations
Sub Title (in English)
Keyword(1) Fukushima Dai ichi
Keyword(2) Isolation Condenser
Keyword(3) HPCI
Keyword(4) Turuga Unit. 1
Keyword(5) Reactor Water Level
Keyword(6) Safety Operation
1st Author's Name Noboru KUSAMA
1st Author's Affiliation ()
Date 2014-03-13
Paper # SSS2013-34
Volume (vol) vol.113
Number (no) 490
Page pp.pp.-
#Pages 4
Date of Issue