Abstract(in English) We propose a calibration method of frequency response of PDs, which use Mach Zehnder optical intensity modulator. Based on the so-called heterodyne technique, National Institute of Standard and Technology (NIST) have been providing an O/E transfer standard implemented by two Nd : YAG lasers with a complex control systems. Our goal is a simple and easy O/E transfer standard that ordinary users could use it for calibrating their PDs at their laboratories. Such a scheme could be expected to improve the uncertainty drastically. In this paper, we first explain the heterodyne technique and the properties required to the two-lightwave source of the O/E transfer standard. Then, how to implement it by MZ modulator, and how to assure the criterion of "identical power" between two lightwaves are proposed. At last a trial calibration results demonstrated the potential of the proposed calibration method.
Keyword(in Japanese) (See Japanese page)
Keyword(in English) PD frequency response calibration / O/E transfer standard / Carrier suppression ratio monitor / High extinction ratio Mach Zehnder optical modulator
Paper # MW2011-57,OPE2011-44,EST2011-43,MWP2011-25
Date of Issue

Conference Information
Committee MW
Conference Date 2011/7/14(1days)
Place (in Japanese) (See Japanese page)
Place (in English)
Topics (in Japanese) (See Japanese page)
Topics (in English)
Chair
Vice Chair
Secretary
Assistant

Paper Information
Registration To Microwaves (MW)
Language JPN
Title (in Japanese) (See Japanese page)
Sub Title (in Japanese) (See Japanese page)
Title (in English) PD Frequency Response Calibration Method Using Mach-Zehnder Modulator : Comparison with Conventional Method and Error Analysis
Sub Title (in English)
Keyword(1) PD frequency response calibration
Keyword(2) O/E transfer standard
Keyword(3) Carrier suppression ratio monitor
Keyword(4) High extinction ratio Mach Zehnder optical modulator
1st Author's Name Keizo INAGAKI
1st Author's Affiliation Photonic Network Research Institute, National Institute of Information and Communications Technology()
2nd Author's Name Ukrit MANKONG
2nd Author's Affiliation Photonic Network Research Institute, National Institute of Information and Communications Technology:Telecommunication Research and Industrial Development Institute (TRIDI)
3rd Author's Name Tetsuya KAWANISHI
3rd Author's Affiliation Photonic Network Research Institute, National Institute of Information and Communications Technology
Date 2011-07-22
Paper # MW2011-57,OPE2011-44,EST2011-43,MWP2011-25
Volume (vol) vol.111
Number (no) 147
Page pp.pp.-
#Pages 6
Date of Issue