Presentation 2010-10-22
Amplitude Calibration on Electric Field Measurement with Modulated Scatterer
Takahiro KUROSAWA, Takashi KOMAKINE,
PDF Download Page PDF download Page Link
Abstract(in Japanese) (See Japanese page)
Abstract(in English) A calibration method on electric field measurement system with modulated scattering technique is developed. By using rotating di-electric cylinder as modulated scatterer and log-periodic dipole array antenna as an equipment under test(EUT), calibration coefficient was measured. The dependence of calibration coefficient on scatterer position shows the multipath interference of scattered waves such as floor reflection and the reflection of EUT. Electric field of the EUT can be measured by using modulated scattering technique and this calibration method with good accuracy.
Keyword(in Japanese) (See Japanese page)
Keyword(in English) Electric field measurement / Modulated scatterer / Calibration / EMC / Anechoic chamber
Paper # EMCJ2010-65,MW2010-100
Date of Issue

Conference Information
Committee EMCJ
Conference Date 2010/10/14(1days)
Place (in Japanese) (See Japanese page)
Place (in English)
Topics (in Japanese) (See Japanese page)
Topics (in English)
Chair
Vice Chair
Secretary
Assistant

Paper Information
Registration To Electromagnetic Compatibility (EMCJ)
Language JPN
Title (in Japanese) (See Japanese page)
Sub Title (in Japanese) (See Japanese page)
Title (in English) Amplitude Calibration on Electric Field Measurement with Modulated Scatterer
Sub Title (in English)
Keyword(1) Electric field measurement
Keyword(2) Modulated scatterer
Keyword(3) Calibration
Keyword(4) EMC
Keyword(5) Anechoic chamber
1st Author's Name Takahiro KUROSAWA
1st Author's Affiliation AKITA Prefectural R&D Center()
2nd Author's Name Takashi KOMAKINE
2nd Author's Affiliation AKITA Prefectural R&D Center
Date 2010-10-22
Paper # EMCJ2010-65,MW2010-100
Volume (vol) vol.110
Number (no) 236
Page pp.pp.-
#Pages 4
Date of Issue