Presentation | 2010-07-15 Evaluation Method for EMI of an Implanted Device by Wireless Devices Using Near-field EMF Satoshi ISHIHARA, Takahiro IYAMA, Teruo ONISHI, Yoshiaki TARUSAWA, |
---|---|
PDF Download Page | PDF download Page Link |
Abstract(in Japanese) | (See Japanese page) |
Abstract(in English) | The objective of this study is to establish electromagnetic interference (EMI) evaluation techniques for wireless devices that use the near-field electromagnetic field (EMF), especially body area network (BAN) devices. The torso phantom is employed for an EMI evaluation. The EMI evaluation method is valid in cases that the induced voltage at a device placed in the torso phantom is higher than that for a device implanted in a human body. As a calculation method, the Finite-Difference Time-Domain (FDTD) method is used. Two types of transmitters are used as BAN devices. Transmitters 1 and 2 induce an electric field that surrounds the whole human body and near the transmitter, respectively. As a result, when using transmitters 1 and 2, voltages induced at the device placed in the torso phantom are 5.7 and 3.2 dB higher than that implanted in the human body, respectively. Consequently, it is confirmed that the EMI evaluation method using the torso phantom can be used. |
Keyword(in Japanese) | (See Japanese page) |
Keyword(in English) | Near-field EMF / EMI evaluation method / Torso phantom / Implanted device |
Paper # | EMCJ2010-25 |
Date of Issue |
Conference Information | |
Committee | EMCJ |
---|---|
Conference Date | 2010/7/8(1days) |
Place (in Japanese) | (See Japanese page) |
Place (in English) | |
Topics (in Japanese) | (See Japanese page) |
Topics (in English) | |
Chair | |
Vice Chair | |
Secretary | |
Assistant |
Paper Information | |
Registration To | Electromagnetic Compatibility (EMCJ) |
---|---|
Language | JPN |
Title (in Japanese) | (See Japanese page) |
Sub Title (in Japanese) | (See Japanese page) |
Title (in English) | Evaluation Method for EMI of an Implanted Device by Wireless Devices Using Near-field EMF |
Sub Title (in English) | |
Keyword(1) | Near-field EMF |
Keyword(2) | EMI evaluation method |
Keyword(3) | Torso phantom |
Keyword(4) | Implanted device |
1st Author's Name | Satoshi ISHIHARA |
1st Author's Affiliation | NTT DOCOMO, INC.() |
2nd Author's Name | Takahiro IYAMA |
2nd Author's Affiliation | NTT DOCOMO, INC. |
3rd Author's Name | Teruo ONISHI |
3rd Author's Affiliation | NTT DOCOMO, INC. |
4th Author's Name | Yoshiaki TARUSAWA |
4th Author's Affiliation | NTT DOCOMO, INC. |
Date | 2010-07-15 |
Paper # | EMCJ2010-25 |
Volume (vol) | vol.110 |
Number (no) | 125 |
Page | pp.pp.- |
#Pages | 6 |
Date of Issue |