Presentation | 2008-12-19 A study on loop-tube type thermoacoustic cooling system for practical use : The effect of installation positions and inner diameters of the diverging tube Takahiro ISHINO, Shin-ichi SAKAMOTO, Shintaro KOMIYA, Yoshiaki WATANABE, |
---|---|
PDF Download Page | PDF download Page Link |
Abstract(in Japanese) | (See Japanese page) |
Abstract(in English) | In this report, a design method of loop-tube type thermoacoustic cooling system with diverging tube to improve energy conversion efficiency from heat energy to sound energy is proposed. We focus on sound field within a loop-tube when installations position and inner diameters of diverging tube is changed. Installation positions of diverging tube are changed near the top of the prime mover stack and center of loop tube of 1.65m. Two kinds of inner diameters of 42mm and 24mm are used. From the experiment results, sound field was greatly different according to the installation positions of diverging tube. In setting up the diverging tube at antinode of particle velocity of the second wavelength resonance, first order resonance component and traveling wave phase were increased. In addition, it is considered that sound field was changed for boundary condition was changed by the kind of the inner diameters. |
Keyword(in Japanese) | (See Japanese page) |
Keyword(in English) | Thermoacoustics / Loop-tube / Diverging tube / Installation positions and inner diameters / Phase difference between sound pressure and particle velocity |
Paper # | US2008-69 |
Date of Issue |
Conference Information | |
Committee | US |
---|---|
Conference Date | 2008/12/12(1days) |
Place (in Japanese) | (See Japanese page) |
Place (in English) | |
Topics (in Japanese) | (See Japanese page) |
Topics (in English) | |
Chair | |
Vice Chair | |
Secretary | |
Assistant |
Paper Information | |
Registration To | Ultrasonics (US) |
---|---|
Language | JPN |
Title (in Japanese) | (See Japanese page) |
Sub Title (in Japanese) | (See Japanese page) |
Title (in English) | A study on loop-tube type thermoacoustic cooling system for practical use : The effect of installation positions and inner diameters of the diverging tube |
Sub Title (in English) | |
Keyword(1) | Thermoacoustics |
Keyword(2) | Loop-tube |
Keyword(3) | Diverging tube |
Keyword(4) | Installation positions and inner diameters |
Keyword(5) | Phase difference between sound pressure and particle velocity |
1st Author's Name | Takahiro ISHINO |
1st Author's Affiliation | Faculty of Engineering, Doshisha University() |
2nd Author's Name | Shin-ichi SAKAMOTO |
2nd Author's Affiliation | Department of Electronic Systems Engineering, University of Shiga Prefecture |
3rd Author's Name | Shintaro KOMIYA |
3rd Author's Affiliation | Faculty of Engineering, Doshisha University |
4th Author's Name | Yoshiaki WATANABE |
4th Author's Affiliation | Faculty of Life and Medical Sciences, Doshisha University |
Date | 2008-12-19 |
Paper # | US2008-69 |
Volume (vol) | vol.108 |
Number (no) | 364 |
Page | pp.pp.- |
#Pages | 6 |
Date of Issue |