講演名 2007/1/25
IEC機能安全規格の改訂動向 : 安全側故障割合(SFF)の要求事項について
佐藤 吉信,
PDFダウンロードページ PDFダウンロードページへ
抄録(和)
抄録(英) The standard of functional safety requires the subsystems of safety-related system(SRS) to conform with architectural constraints consisting of both random hardware-fault tolerance and safe failure fraction(SFF) constraints as denoted in Part 2 of the standard. The architectural constraints put limitations on the claim that the subsystems can have the highest safety-integrity level(SIL). Therefore, the constraints are highly important requirements as well as those on SIL in the standard. However, the constraints look like themselves to contradict logically the SIL requirements in Part 1 of the standard. Thus, in the present paper how and why the SFF constraints do not bring about logical coherency in the standard is discussed and examined.
キーワード(和)
キーワード(英) Functional Safety / Safety Integrity Level / SIL / Safe Failure Fraction / SFF
資料番号 SSS2006-32
発行日

研究会情報
研究会 SSS
開催期間 2007/1/25(から1日開催)
開催地(和)
開催地(英)
テーマ(和)
テーマ(英)
委員長氏名(和)
委員長氏名(英)
副委員長氏名(和)
副委員長氏名(英)
幹事氏名(和)
幹事氏名(英)
幹事補佐氏名(和)
幹事補佐氏名(英)

講演論文情報詳細
申込み研究会 Safety (SSS)
本文の言語 ENG
タイトル(和) IEC機能安全規格の改訂動向 : 安全側故障割合(SFF)の要求事項について
サブタイトル(和)
タイトル(英) Status of the IEC Standard of Functional Safety for Revision : On the Requirement of Safe Failure Fraction(SFF)
サブタイトル(和)
キーワード(1)(和/英) / Functional Safety
第 1 著者 氏名(和/英) 佐藤 吉信 / Yoshinobu SATO
第 1 著者 所属(和/英) 東京海洋大学海洋工学部
Faculty of Engineering, Tokyo University of Marine Science & Technology
発表年月日 2007/1/25
資料番号 SSS2006-32
巻番号(vol) vol.106
号番号(no) 519
ページ範囲 pp.-
ページ数 4
発行日