Abstract(in English) Fault tree analysis (FTA) is generally accepted as an efficient method for analyzing system failures. A probabilistic model for analyzing the sequential failure logic and equation with multiple integration were presented for a single minimal cut AND structure. The present paper demonstrates how to estimate the statistically expected number of occurrences of the top event per unit time at time t, ω_ (t), by use of the multiple integration method and software Mathematica for the cases where inputs have different failure and repair rates.
Keyword(in Japanese) (See Japanese page)
Keyword(in English) Fault tree analysis and Sequential failure logic
Paper # SSS99-29
Date of Issue

Conference Information
Committee SSS
Conference Date 1999/12/17(1days)
Place (in Japanese) (See Japanese page)
Place (in English)
Topics (in Japanese) (See Japanese page)
Topics (in English)
Chair
Vice Chair
Secretary
Assistant

Paper Information
Registration To Safety (SSS)
Language JPN
Title (in Japanese) (See Japanese page)
Sub Title (in Japanese) (See Japanese page)
Title (in English) Application of sequential failure logic to FTA
Sub Title (in English)
Keyword(1) Fault tree analysis and Sequential failure logic
1st Author's Name Wei LONG
1st Author's Affiliation Tokyo University of Mercantile Marine()
2nd Author's Name Yoshinobu SATO
2nd Author's Affiliation Tokyo University of Mercantile Marine
Date 1999/12/17
Paper # SSS99-29
Volume (vol) vol.99
Number (no) 517
Page pp.pp.-
#Pages 6
Date of Issue