Presentation | 2005-09-09 Measurement of LCL and common mode impedance at outlet in house Terushi SHINPOU, Tomio NISHIYAMA, Koji MAEGAWA, Naoki ISHIKAWA, Tsutomu INADA, Masahiro MAKI, |
---|---|
PDF Download Page | PDF download Page Link |
Abstract(in Japanese) | (See Japanese page) |
Abstract(in English) | A radiation of electromagnetic field from electric wire in power-line carrier communication is related to the common mode electric current which flows to electric wire. A common mode electric current is led by LCL (Longitudinal Conversion Loss) of differential output of a modem, electric wire and common mode impedance. So, common mode impedance and LCL was measured with 487 samples of electric wire in domestic wooden house, non-wooden house and apartment. It became clear as a result, a mean of LCL was 35.5dB, and a mean of common mode impedance is 240.7Ω. |
Keyword(in Japanese) | (See Japanese page) |
Keyword(in English) | Power-line carrier communication / LCL (Longitudinal Conversion Loss) / Common mode impedance |
Paper # | EMCJ2005-70 |
Date of Issue |
Conference Information | |
Committee | EMCJ |
---|---|
Conference Date | 2005/9/1(1days) |
Place (in Japanese) | (See Japanese page) |
Place (in English) | |
Topics (in Japanese) | (See Japanese page) |
Topics (in English) | |
Chair | |
Vice Chair | |
Secretary | |
Assistant |
Paper Information | |
Registration To | Electromagnetic Compatibility (EMCJ) |
---|---|
Language | JPN |
Title (in Japanese) | (See Japanese page) |
Sub Title (in Japanese) | (See Japanese page) |
Title (in English) | Measurement of LCL and common mode impedance at outlet in house |
Sub Title (in English) | |
Keyword(1) | Power-line carrier communication |
Keyword(2) | LCL (Longitudinal Conversion Loss) |
Keyword(3) | Common mode impedance |
1st Author's Name | Terushi SHINPOU |
1st Author's Affiliation | Information & Instrumentation System Dept., and Network Construction Dept., KINDEN Corporation() |
2nd Author's Name | Tomio NISHIYAMA |
2nd Author's Affiliation | Information & Instrumentation System Dept., and Network Construction Dept., KINDEN Corporation |
3rd Author's Name | Koji MAEGAWA |
3rd Author's Affiliation | Engineering Group, LINECOM Co., Inc. |
4th Author's Name | Naoki ISHIKAWA |
4th Author's Affiliation | Mitsubishi Electric Corporation |
5th Author's Name | Tsutomu INADA |
5th Author's Affiliation | Matsushita Electric Works Analysis Center., Ltd. |
6th Author's Name | Masahiro MAKI |
6th Author's Affiliation | Panasonic Communications |
Date | 2005-09-09 |
Paper # | EMCJ2005-70 |
Volume (vol) | vol.105 |
Number (no) | 263 |
Page | pp.pp.- |
#Pages | 6 |
Date of Issue |