Presentation 2004/10/21
Results of the comparison between the conventional and the using normalized site attenuation method for shielding effectiveness measurement
Takuya HOSHINO, Mamoru SATO, Masaharu SAO, Tetsuya TOMINAGA,
PDF Download Page PDF download Page Link
Abstract(in Japanese) (See Japanese page)
Abstract(in English) The transmission loss method of the IEEE std.299-1997 and the insertion loss method of the IEC TS 61587-3 are widely used as a shield effectiveness evaluation method for shield chambers however, measurement of reference loss is necessary in these evaluation methods, therefore these estimation methods require prolonged measurements and include problems in the reproducibility of reference loss. We had proposed a procedure to evaluate a shielding effectiveness using a normalized site attenuation method in order to solve the above-mentioned problems. In this paper we proposed a new frequency sweep shielding effectiveness measurement method using normalized site attenuation data which was measured using a transmitting antenna. And we also compared the shield effectiveness measured in Fully Anechoic Chamber using insertion loss method and in Semi-Anechoic Chamber using transmission loss method, with the shield effectiveness measured in each Chamber using frequency sweep method, respectively. According to the measured data, almost same results were obtained both by the proposed method and by the conventional method, and by using this proposed method, measurement time was able to be made into the half compared with the conventional method.
Keyword(in Japanese) (See Japanese page)
Keyword(in English) Normalized site attenuation / electromagnetic shelding / measurement procedure / IEEEstd.299-1997
Paper # EMCJ2004-70,MW2004-146
Date of Issue

Conference Information
Committee EMCJ
Conference Date 2004/10/21(1days)
Place (in Japanese) (See Japanese page)
Place (in English)
Topics (in Japanese) (See Japanese page)
Topics (in English)
Chair
Vice Chair
Secretary
Assistant

Paper Information
Registration To Electromagnetic Compatibility (EMCJ)
Language JPN
Title (in Japanese) (See Japanese page)
Sub Title (in Japanese) (See Japanese page)
Title (in English) Results of the comparison between the conventional and the using normalized site attenuation method for shielding effectiveness measurement
Sub Title (in English)
Keyword(1) Normalized site attenuation
Keyword(2) electromagnetic shelding
Keyword(3) measurement procedure
Keyword(4) IEEEstd.299-1997
1st Author's Name Takuya HOSHINO
1st Author's Affiliation NTT Advanced Technology Co.()
2nd Author's Name Mamoru SATO
2nd Author's Affiliation NTT Advanced Technology Co.
3rd Author's Name Masaharu SAO
3rd Author's Affiliation NTT Environment and Energy Labs.
4th Author's Name Tetsuya TOMINAGA
4th Author's Affiliation NTT Environment and Energy Labs.
Date 2004/10/21
Paper # EMCJ2004-70,MW2004-146
Volume (vol) vol.104
Number (no) 382
Page pp.pp.-
#Pages 6
Date of Issue