Presentation 1998/5/15
Specifications and Characteristics of Anechoic Chamber Built in Kyusyu Institute of Technology(Version 2)
Kazuo Shimada, Hiroyoshi Ishii, Masamitsu Tokuda,
PDF Download Page PDF download Page Link
Abstract(in Japanese) (See Japanese page)
Abstract(in English) We reported about specifications and characteristics of anechoic chamber built in Kyushu Institute of Technology. The EMC measurement anechoic chamber was able to have excellent characteristics from 30MHz to 10GHz, to adopt RF cascaded absorber bellow 11cm height which is consist of new developed ferrite foam and ferrite.
Keyword(in Japanese) (See Japanese page)
Keyword(in English) Porous ferrite / Anechoic Chamber / Microwave absorber / Pyramidal absorber / Immunity test
Paper #
Date of Issue

Conference Information
Committee EMCJ
Conference Date 1998/5/15(1days)
Place (in Japanese) (See Japanese page)
Place (in English)
Topics (in Japanese) (See Japanese page)
Topics (in English)
Chair
Vice Chair
Secretary
Assistant

Paper Information
Registration To Electromagnetic Compatibility (EMCJ)
Language JPN
Title (in Japanese) (See Japanese page)
Sub Title (in Japanese) (See Japanese page)
Title (in English) Specifications and Characteristics of Anechoic Chamber Built in Kyusyu Institute of Technology(Version 2)
Sub Title (in English)
Keyword(1) Porous ferrite
Keyword(2) Anechoic Chamber
Keyword(3) Microwave absorber
Keyword(4) Pyramidal absorber
Keyword(5) Immunity test
1st Author's Name Kazuo Shimada
1st Author's Affiliation Riken Eletech Corporation()
2nd Author's Name Hiroyoshi Ishii
2nd Author's Affiliation Kyusyu Institute of Technology
3rd Author's Name Masamitsu Tokuda
3rd Author's Affiliation Kyusyu Institute of Technology
Date 1998/5/15
Paper #
Volume (vol) vol.98
Number (no) 51
Page pp.pp.-
#Pages 8
Date of Issue