Presentation | 2018-03-16 Non-Contact Biometric authentication using Microwave Doppler Sensor Takaaki Okano, Shintaro Izumi, Hiroshi Kawaguchi, Masahiko Yoshimoto, |
---|---|
PDF Download Page | PDF download Page Link |
Abstract(in Japanese) | (See Japanese page) |
Abstract(in English) | In this paper, we propose a non-contact biometric authentication method using a microwave Doppler sensor. In the proposed method, the heartbeat component is measured as personal characteristic information attributable to individual differences in the myocardium and blood vessels. The microwave Doppler sensor can detect minute vibrations of the body surface caused by heartbeat, however the salient difficulty of the sensor is noise contamination such as that caused by body motion. This study introduces the use of time?frequency analysis with an autoregressive model to reduce the noise influence and emphasize heartbeat features. Frequency features of the heartbeat component are used for ID generation. The proposed method was evaluated using measurements taken of 11 participants. Measurement results show a 92.8% true acceptance rate and a 3.9% equal error rate. |
Keyword(in Japanese) | (See Japanese page) |
Keyword(in English) | microwave Doppler sensor / biometric authentication / heartbeat / non-contact |
Paper # | MICT2017-54 |
Date of Issue | 2018-03-09 (MICT) |
Conference Information | |
Committee | EMCJ / MICT |
---|---|
Conference Date | 2018/3/16(1days) |
Place (in Japanese) | (See Japanese page) |
Place (in English) | Kikai-Shinko-Kaikan Bldg. |
Topics (in Japanese) | (See Japanese page) |
Topics (in English) | EMC |
Chair | Osami Wada(Kyoto Univ.) / Masaru Sugimachi(National Cerebral and Cardiovascular Center) |
Vice Chair | Kensei Oh(Nagoya Inst. of Tech.) / Shinsuke Hara(Osaka City Univ.) / Takahiro Aoyagi(Tokyo Inst. of Tech.) |
Secretary | Kensei Oh(AIST) / Shinsuke Hara(Mitsubishi Electric) / Takahiro Aoyagi(Niigata Univ.) |
Assistant | Shinichiro Yamamoto(Univ. of Hyogo) / Chie Sasaki(Panasonic) / Shinobu Nagasawa(Mitsubishi Electric) / Takumi Kobayashi(Yokohama National Univ.) / Shintaro Izumi(Kobe Univ.) / Tomoko Tateyama(Hiroshima Inst. of Tech.) / Ami Tanaka(Ritsumeikan Univ.) / Daisuke Anzai(Nagoya Inst. of Tech.) |
Paper Information | |
Registration To | Technical Committee on Electromagnetic Compatibility / Technical Committee on Healthcare and Medical Information Communication Technology |
---|---|
Language | JPN |
Title (in Japanese) | (See Japanese page) |
Sub Title (in Japanese) | (See Japanese page) |
Title (in English) | Non-Contact Biometric authentication using Microwave Doppler Sensor |
Sub Title (in English) | |
Keyword(1) | microwave Doppler sensor |
Keyword(2) | biometric authentication |
Keyword(3) | heartbeat |
Keyword(4) | non-contact |
1st Author's Name | Takaaki Okano |
1st Author's Affiliation | Kobe University(Kobe Univ.) |
2nd Author's Name | Shintaro Izumi |
2nd Author's Affiliation | Kobe University(Kobe Univ.) |
3rd Author's Name | Hiroshi Kawaguchi |
3rd Author's Affiliation | Kobe University(Kobe Univ.) |
4th Author's Name | Masahiko Yoshimoto |
4th Author's Affiliation | Kobe University(Kobe Univ.) |
Date | 2018-03-16 |
Paper # | MICT2017-54 |
Volume (vol) | vol.117 |
Number (no) | MICT-511 |
Page | pp.pp.17-20(MICT), |
#Pages | 4 |