Presentation | 2018-01-30 Limit Operating Frequency of Peak Current Mode Control DC-DC Converter Considering Turn-Off Delay Time Ryo Ute, Kazuya Fujiwara, Jun Imaoka, Masahito Shoyama, |
---|---|
PDF Download Page | PDF download Page Link |
Abstract(in Japanese) | (See Japanese page) |
Abstract(in English) | Peak current mode control is a widely used control method for DC-DC converter because it has higher stability and responsibility than the voltage mode control. However, if the switching frequency is increased ignoring the turn-off delay time, it may become the dividing frequency operation. In this operation, the switching frequency is not equal to the clock frequency and can not drive with high switching frequency. In this paper, we clarified the mechanism of the dividing frequency operation and derived the relationship between the turn-off delay time and the limit operating frequency of the DC-DC converter. Also, we derived the relationship when we applied the slope compensation as well. As experimental results, when there is the delay time, it was confirmed that the limit operating frequency of the DC-DC converter is limited lower as the duty ratio is lower and the slope is larger. |
Keyword(in Japanese) | (See Japanese page) |
Keyword(in English) | peak current mode control / turn-off delay time / dividing frequency operation / limit operating frequency / slope compensation |
Paper # | EE2017-73 |
Date of Issue | 2018-01-22 (EE) |
Conference Information | |
Committee | EE |
---|---|
Conference Date | 2018/1/29(2days) |
Place (in Japanese) | (See Japanese page) |
Place (in English) | Satellite Campus Oita |
Topics (in Japanese) | (See Japanese page) |
Topics (in English) | |
Chair | Fujio Kurokawa(Nagasaki Univ.) |
Vice Chair | Masatoshi Nakahara(Sojo Univ.) / Keiichi Hirose(NTT-F) |
Secretary | Masatoshi Nakahara(Fukuoka Univ.) / Keiichi Hirose |
Assistant | kazuhiro Kajiwara(NiAS) / Takashi Matsushita(NTT-F) / Hidenori Maruta(Nagasaki Univ.) |
Paper Information | |
Registration To | Technical Committee on Energy Engineering in Electronics and Communications |
---|---|
Language | JPN |
Title (in Japanese) | (See Japanese page) |
Sub Title (in Japanese) | (See Japanese page) |
Title (in English) | Limit Operating Frequency of Peak Current Mode Control DC-DC Converter Considering Turn-Off Delay Time |
Sub Title (in English) | |
Keyword(1) | peak current mode control |
Keyword(2) | turn-off delay time |
Keyword(3) | dividing frequency operation |
Keyword(4) | limit operating frequency |
Keyword(5) | slope compensation |
1st Author's Name | Ryo Ute |
1st Author's Affiliation | Kyushu University(Kyushu Univ.) |
2nd Author's Name | Kazuya Fujiwara |
2nd Author's Affiliation | Kyushu University(Kyushu Univ.) |
3rd Author's Name | Jun Imaoka |
3rd Author's Affiliation | Kyushu University(Kyushu Univ.) |
4th Author's Name | Masahito Shoyama |
4th Author's Affiliation | Kyushu University(Kyushu Univ.) |
Date | 2018-01-30 |
Paper # | EE2017-73 |
Volume (vol) | vol.117 |
Number (no) | EE-424 |
Page | pp.pp.177-182(EE), |
#Pages | 6 |
Date of Issue | 2018-01-22 (EE) |