Presentation | 2017-06-27 Development of the inner rotor type coiled stator ultrasound motor using wire acoustic waveguide and hollow pipe rotor for intravascular ultrasound system Choyu Uehara, Keisuke Kurita, Seiya Ozeki, Shinichi Takeuchi, |
---|---|
PDF Download Page | PDF download Page Link |
Abstract(in Japanese) | (See Japanese page) |
Abstract(in English) | We have been developing the coiled stator ultrasound motor (CS-USM), which is a miniature motor capable of installing a driving source at tip of the catheter, for the purpose of application to intravascular ultrasound (IVUS). Outer rotor type CS-USM has been reported for the offline imaging, however since the driving source is outside of the body, it is necessary to review the structure of CS-USM. Inner rotor type CS-USM has the positional relationship of right angle between the coiled stator and the PZT transducer for it is inappropriate for practical application. In this report, we proposed a structure for practical application by using inner rotor type CS-USM and measured the rotation speed. As a result, measured rotational speed of our CS-USM was higher than 1800 rpm which is the required for rotation speed of IVUS. |
Keyword(in Japanese) | (See Japanese page) |
Keyword(in English) | Coiled stator / CS-USM / Ultrasound motor / Revolution speed / Inner rotor |
Paper # | US2017-27 |
Date of Issue | 2017-06-20 (US) |
Conference Information | |
Committee | US |
---|---|
Conference Date | 2017/6/27(1days) |
Place (in Japanese) | (See Japanese page) |
Place (in English) | |
Topics (in Japanese) | (See Japanese page) |
Topics (in English) | |
Chair | Minoru Kurosawa(Tokyo Inst. of Tech.) |
Vice Chair | Nobuyuki Endoh(KU) / Shinichi Takeuchi(Toin Univ. of Yokohama) |
Secretary | Nobuyuki Endoh(Univ. of Toyama) / Shinichi Takeuchi(Univ. of Tokyo) |
Assistant | Takenobu Tsuchiya(KU) |
Paper Information | |
Registration To | Technical Committee on Ultrasonics |
---|---|
Language | JPN |
Title (in Japanese) | (See Japanese page) |
Sub Title (in Japanese) | (See Japanese page) |
Title (in English) | Development of the inner rotor type coiled stator ultrasound motor using wire acoustic waveguide and hollow pipe rotor for intravascular ultrasound system |
Sub Title (in English) | |
Keyword(1) | Coiled stator |
Keyword(2) | CS-USM |
Keyword(3) | Ultrasound motor |
Keyword(4) | Revolution speed |
Keyword(5) | Inner rotor |
1st Author's Name | Choyu Uehara |
1st Author's Affiliation | Toin University of Yokohama(Toin Univ. of Yokohama) |
2nd Author's Name | Keisuke Kurita |
2nd Author's Affiliation | Toin University of Yokohama(Toin Univ. of Yokohama) |
3rd Author's Name | Seiya Ozeki |
3rd Author's Affiliation | Toin University of Yokohama(Toin Univ. of Yokohama) |
4th Author's Name | Shinichi Takeuchi |
4th Author's Affiliation | Toin University of Yokohama(Toin Univ. of Yokohama) |
Date | 2017-06-27 |
Paper # | US2017-27 |
Volume (vol) | vol.117 |
Number (no) | US-111 |
Page | pp.pp.37-41(US), |
#Pages | 5 |
Date of Issue | 2017-06-20 (US) |