Presentation 2017-05-12
A Study for the Adaptive Error Correction in Wireless Vision Based Feedback Control under Implant Body Area Network
Satoshi Seimiya, Kento Takabayashi, Ryuji Kohno,
PDF Download Page PDF download Page Link
Abstract(in Japanese) (See Japanese page)
Abstract(in English) The capsule endoscope is one of the typical advanced medical devices using wireless information and communication technology(ICT). At present, it uses one-way communication system. However, with the improvement of the loaded battery's life, we can expect that it can use bidirectional communication system and it will be able to get the medical data more effectively. In order to define the importance and the processing time of each data, in this study, we established the wireless feedback model, in which the controller changes the PWM (Pulse Width Modulation) Signal adaptively based on the captured image by the rotary camera gathered through the wireless uplink.
Keyword(in Japanese) (See Japanese page)
Keyword(in English) Wireless Visual Feedback Control / Implant BAN / Unequal Error Protection / IEEE802.15.6 CM2
Paper # RCC2017-7,MICT2017-7
Date of Issue 2017-05-04 (RCC, MICT)

Conference Information
Committee RCC / MICT
Conference Date 2017/5/11(2days)
Place (in Japanese) (See Japanese page)
Place (in English) Kikai-Shinko-Kaikan Bldg.
Topics (in Japanese) (See Japanese page)
Topics (in English) Reliable Communication and Control, Healthcare and Medical Information Communication Technologies, etc.
Chair Shinsuke Hara(Osaka City Univ.) / Masaru Sugimachi(National Cerebral and Cardiovascular Center)
Vice Chair Kazunori Hayashi(Kyoto Univ.) / Ryu Miura(NICT) / Shinsuke Hara(Osaka City Univ.) / Takahiro Aoyagi(Tokyo Inst. of Tech.)
Secretary Kazunori Hayashi(Kagawa Univ.) / Ryu Miura(Hokkaido Univ.) / Shinsuke Hara(Niigata Univ.) / Takahiro Aoyagi(Saga Univ.)
Assistant Toshinori Kagawa(NICT) / Kentaro Kobayashi(Nagoya Univ.) / Kohei Ohno(Meiji Univ.) / Keisuke Shima(Yokohama National Univ.) / Tomoko Tateyama(Hiroshima Inst. of Tech.) / Ami Tanaka(Ritsumeikan Univ.) / Daisuke Anzai(Nagoya Inst. of Tech.)

Paper Information
Registration To Technical Committee on Reliable Communication and Control / Technical Committee on Healthcare and Medical Information Communication Technology
Language JPN
Title (in Japanese) (See Japanese page)
Sub Title (in Japanese) (See Japanese page)
Title (in English) A Study for the Adaptive Error Correction in Wireless Vision Based Feedback Control under Implant Body Area Network
Sub Title (in English)
Keyword(1) Wireless Visual Feedback Control
Keyword(2) Implant BAN
Keyword(3) Unequal Error Protection
Keyword(4) IEEE802.15.6 CM2
1st Author's Name Satoshi Seimiya
1st Author's Affiliation Yokohama National University(Yokohama National Univ.)
2nd Author's Name Kento Takabayashi
2nd Author's Affiliation Okayama Prefectural University(Okayama Prefectural Univ.)
3rd Author's Name Ryuji Kohno
3rd Author's Affiliation Yokohama National University(Yokohama National Univ.)
Date 2017-05-12
Paper # RCC2017-7,MICT2017-7
Volume (vol) vol.117
Number (no) RCC-19,MICT-20
Page pp.pp.31-35(RCC), pp.31-35(MICT),
#Pages 5
Date of Issue 2017-05-04 (RCC, MICT)