Presentation | 2017-01-19 Evaluation of Unintended electromagnetic radiation from Myoelectric Artificial Hand Yoshitaka Toyota, |
---|---|
PDF Download Page | PDF download Page Link |
Abstract(in Japanese) | (See Japanese page) |
Abstract(in English) | At this moment, there are no limits nor methods of the emission measurements for wearable electronic and robotic equipment to hold highly technology-mixed configuration, such as myoelectric artificial hands. To accelerate the study for the standardization of the limits and methods of the emission measurements in this field, Wearable Subcommittee Meeting of UEC Gigabit Research Consortium evaluates and discusses the emission from the myoelectric artificial hands. This paper describes the preliminary experiment to investigate maximum radiated emissions under a couple of conditions, and the results of the radiated emissions evaluated according to CISPR Publication, under the condition of continuous movement, i.e. open the hand and clench the fist alternatively, in which the maximum radiated emissions were observed in the preliminary experiment. |
Keyword(in Japanese) | (See Japanese page) |
Keyword(in English) | myoelectric artificial hands / wearable electronic and robotic equipment / standardization of limits and methods / electromagnetic interference (EMI) / continuous movement |
Paper # | EMCJ2016-111 |
Date of Issue | 2017-01-12 (EMCJ) |
Conference Information | |
Committee | EMCJ |
---|---|
Conference Date | 2017/1/19(2days) |
Place (in Japanese) | (See Japanese page) |
Place (in English) | Kyushu Institute of Technology |
Topics (in Japanese) | (See Japanese page) |
Topics (in English) | Communication, EMC |
Chair | Hideaki Sone(Tohoku Univ.) |
Vice Chair | Osami Wada(Kyoto Univ.) |
Secretary | Osami Wada(AIST) |
Assistant | Yoshiki Kayano(Univ. of Electro-Comm.) / Yusaku Katsube(Hitachi) / Chie Sasaki(Panasonic) |
Paper Information | |
Registration To | Technical Committee on Electromagnetic Compatibility |
---|---|
Language | JPN |
Title (in Japanese) | (See Japanese page) |
Sub Title (in Japanese) | (See Japanese page) |
Title (in English) | Evaluation of Unintended electromagnetic radiation from Myoelectric Artificial Hand |
Sub Title (in English) | |
Keyword(1) | myoelectric artificial hands |
Keyword(2) | wearable electronic and robotic equipment |
Keyword(3) | standardization of limits and methods |
Keyword(4) | electromagnetic interference (EMI) |
Keyword(5) | continuous movement |
1st Author's Name | Yoshitaka Toyota |
1st Author's Affiliation | Okayama University(Okayama Univ.) |
Date | 2017-01-19 |
Paper # | EMCJ2016-111 |
Volume (vol) | vol.116 |
Number (no) | EMCJ-399 |
Page | pp.pp.15-18(EMCJ), |
#Pages | 4 |