Presentation 2016-11-08
An Evaluation of the System to Identify the Measured Person using Bio-Signal
Haruka Suzuki, Gen Takahashi, Kaori Fujimura, Toru Nakamura, Yukiyoshi Ota,
PDF Download Page PDF download Page Link
Abstract(in Japanese) (See Japanese page)
Abstract(in English) Volumes and varieties of personal data obtained from PCs, smart phones and IoT devices are increasing. In order to provide a service using data obtained by individuals, data authenticity is important. In previous studies, we proposed a method to prevent illegal data registration by unauthorized substitution. In this method, obtained data from user is linked to a subject who is authenticated using collation data. In this paper, this method applied to the blood pressure data measured at home which can be expected to premium calculation of medical insurance. At first, we obtain two pulse waves from the same person in both authentication and blood pressure measurement. Then, we implemented the system of linking authentication result with blood pressure values by collating them. In order to confirm the feasibility of this system, an evaluate experiment was conducted. According to the evaluation, this system’s FAR is 3.8% and FRR is 6.3%. This shows the possibilities of guaranteeing authenticity of data.
Keyword(in Japanese) (See Japanese page)
Keyword(in English) Authenticity / Home blood pressure / Pulse wave
Paper # ISEC2016-61,SITE2016-51,LOIS2016-39
Date of Issue 2016-10-31 (ISEC, SITE, LOIS)

Conference Information
Committee ISEC / LOIS / SITE
Conference Date 2016/11/7(2days)
Place (in Japanese) (See Japanese page)
Place (in English) Community Hall & AOSSA Mall, Fukui
Topics (in Japanese) (See Japanese page)
Topics (in English)
Chair Masahiro Mambo(Kanazawa Univ.) / Hiroyuki Nishi(Sojo Univ.) / Hitoshi Okada(NII)
Vice Chair Kazuto Ogawa(NHK) / Atsushi Fujioka(Kanagawa Univ.) / Tomohiro Yamada(NTT) / Tetsuya Morizumi(Kanagawa Univ.) / Masaru Ogawa(Kobe Gakuin Univ.)
Secretary Kazuto Ogawa(Toshiba) / Atsushi Fujioka(Tohoku Univ.) / Tomohiro Yamada(NTT) / Tetsuya Morizumi(Nagasaki Univ.) / Masaru Ogawa(Kyushu Univ.)
Assistant Toshihiro Ohigashi(Tokai Univ.) / Yuuji Suga(IIJ) / Atsuo Inomata(Tokyo Denki Univ.) / Yukihiro Nakamura(NTT) / Kanako Kawaguchi(Tokyo Univ. of the Arts)

Paper Information
Registration To Technical Committee on Information Security / Technical Committee on Life Intelligence and Office Information Systems / Technical Committee on Social Implications of Technology and Information Ethics
Language JPN
Title (in Japanese) (See Japanese page)
Sub Title (in Japanese) (See Japanese page)
Title (in English) An Evaluation of the System to Identify the Measured Person using Bio-Signal
Sub Title (in English)
Keyword(1) Authenticity
Keyword(2) Home blood pressure
Keyword(3) Pulse wave
1st Author's Name Haruka Suzuki
1st Author's Affiliation Nippon Telegraph and Telephone Corporation(NTT)
2nd Author's Name Gen Takahashi
2nd Author's Affiliation Nippon Telegraph and Telephone Corporation(NTT)
3rd Author's Name Kaori Fujimura
3rd Author's Affiliation Nippon Telegraph and Telephone Corporation(NTT)
4th Author's Name Toru Nakamura
4th Author's Affiliation Nippon Telegraph and Telephone Corporation(NTT)
5th Author's Name Yukiyoshi Ota
5th Author's Affiliation Nippon Telegraph and Telephone Corporation(NTT)
Date 2016-11-08
Paper # ISEC2016-61,SITE2016-51,LOIS2016-39
Volume (vol) vol.116
Number (no) ISEC-289,SITE-290,LOIS-291
Page pp.pp.63-68(ISEC), pp.63-68(SITE), pp.63-68(LOIS),
#Pages 6
Date of Issue 2016-10-31 (ISEC, SITE, LOIS)