Presentation | 2016-10-22 A system to estimate the quantity of urination using a comb-electrode sheet Katsunori Tachibana, Tatsuya Matsui, Takumi Suematsu, Takuya Niikawa, |
---|---|
PDF Download Page | PDF download Page Link |
Abstract(in Japanese) | (See Japanese page) |
Abstract(in English) | We developed a system to estimate the quantity of urination that can electrically detect the impedance changes in auxiliary-pad when wet by the fluid for bedridden elderly patients, without the need to install special sensors in general-auxiliary pads. This study was made to verify of the electrolyte concentration (NaCl) in simulated urine using this system. 4 kinds of simulated urine made of isotonic sodium chloride solution in different electrolyte concentrations and the auxiliary pad has absorbed them certain quantity. Then the auxiliary pad was added at a constant force to the whole by a clear acrylic board from the upper part. We compared the output value of each simulated urine. As a result, the output value was constant regardless of the electrolyte concentration. |
Keyword(in Japanese) | (See Japanese page) |
Keyword(in English) | Bedridden Elderly Patients / Comb-Electrode Sheet / Impedance / Estimate Quantity of Urination / Simulated Urine / Electrolyte Concentration |
Paper # | BioX2016-22,MBE2016-36,NC2016-21 |
Date of Issue | 2016-10-15 (BioX, MBE, NC) |
Conference Information | |
Committee | MBE / BioX / NC |
---|---|
Conference Date | 2016/10/22(1days) |
Place (in Japanese) | (See Japanese page) |
Place (in English) | Osaka Electro-Communication University |
Topics (in Japanese) | (See Japanese page) |
Topics (in English) | |
Chair | Yutaka Fukuoka(Kogakuin Univ.) / Masakatsu Nishigaki(Shizuoka Univ.) / Shigeo Sato(Tohoku Univ.) |
Vice Chair | Kazuki Nakajima(Univ. of Toyama) / Akira Otsuka(AIST) / Hiroshi Takano(Toyama Pref. Univ.) / Masafumi Hagiwara(Keio Univ.) |
Secretary | Kazuki Nakajima(Kogakuin Univ.) / Akira Otsuka(Toyama Pref. Univ.) / Hiroshi Takano(NEC) / Masafumi Hagiwara(AIST) |
Assistant | Ryota Horie(Shibaura Inst. of Tech.) / Kim Juhyon(Univ. of Toyama) / Masatsugu Ichino(Univ. of Electro-Comm.) / Naoyuki Takada(Secom) / Takahiro Aoki(Fujitsu Labs.) / Hisanao Akima(Tohoku Univ.) / Yoshihisa Shinozawa(Keio Univ.) |
Paper Information | |
Registration To | Technical Committee on ME and Bio Cybernetics / Technical Committee on Biometrics / Technical Committee on Neurocomputing |
---|---|
Language | JPN |
Title (in Japanese) | (See Japanese page) |
Sub Title (in Japanese) | (See Japanese page) |
Title (in English) | A system to estimate the quantity of urination using a comb-electrode sheet |
Sub Title (in English) | Consideration of electrolyte concentration in the simulated urine |
Keyword(1) | Bedridden Elderly Patients |
Keyword(2) | Comb-Electrode Sheet |
Keyword(3) | Impedance |
Keyword(4) | Estimate Quantity of Urination |
Keyword(5) | Simulated Urine |
Keyword(6) | Electrolyte Concentration |
1st Author's Name | Katsunori Tachibana |
1st Author's Affiliation | Osaka Electro-Communication University(OECU) |
2nd Author's Name | Tatsuya Matsui |
2nd Author's Affiliation | Osaka Electro-Communication University(OECU) |
3rd Author's Name | Takumi Suematsu |
3rd Author's Affiliation | Osaka Electro-Communication University(OECU) |
4th Author's Name | Takuya Niikawa |
4th Author's Affiliation | Osaka Electro-Communication University(OECU) |
Date | 2016-10-22 |
Paper # | BioX2016-22,MBE2016-36,NC2016-21 |
Volume (vol) | vol.116 |
Number (no) | BioX-263,MBE-264,NC-265 |
Page | pp.pp.31-34(BioX), pp.31-34(MBE), pp.31-34(NC), |
#Pages | 4 |
Date of Issue | 2016-10-15 (BioX, MBE, NC) |