Presentation | 2022-11-18 A Study on Respiratory Rate Measurement Using Wearable CO2 Sensors Mitsuhiro Fukuda, Takunori Shimazaki, Daisuke Anzai, |
---|---|
PDF Download Page | PDF download Page Link |
Abstract(in Japanese) | (See Japanese page) |
Abstract(in English) | It is necessary to obtain respiratory rate with simple devices in order to detect a sudden change in a patient's condition in case of emergency situations. Although the respiratory rate is usually measured based on a combination of impedance change and ECG, the impedance measurement should be largely affected body movement. In contrast, a capnometer used with a ventilator can measure respiratory rate, avoiding body movement influence. However, this method requires the large scale of the device and the connection to the ventilator circuit. Therefore, this study developed a simple respiratory rate measurement system using a wearable CO2 sensor. Then, we experimentally evaluated the estimation accuracy of the respiratory rate based on the wearable CO2 sensor. The experimental results demonstrated that the respiratory rate was precisely measured without being affected by body movement. |
Keyword(in Japanese) | (See Japanese page) |
Keyword(in English) | Respiratory Rate / CO2 sensor |
Paper # | MICT2022-35,MI2022-64 |
Date of Issue | 2022-11-11 (MICT, MI) |
Conference Information | |
Committee | MICT / MI |
---|---|
Conference Date | 2022/11/18(1days) |
Place (in Japanese) | (See Japanese page) |
Place (in English) | Nagoya Institute of Technology |
Topics (in Japanese) | (See Japanese page) |
Topics (in English) | Medical imaging technology, healthcare and medical information communication technology, etc. |
Chair | Hirokazu Tanaka(Hiroshima City Univ.) / Hidekata Hontani(Nagoya Inst. of Tech.) |
Vice Chair | Chika Sugimoto(Yokohama National Univ.) / Daisuke Anzai(Nagoya Inst. of Tech.) / Hideaki Haneishi(Chiba Univ.) / Takayuki Kitasaka(Aichi Inst. of Tech.) |
Secretary | Chika Sugimoto(Okayama Pref. Univ.) / Daisuke Anzai(KISTEC) / Hideaki Haneishi(Yamaguchi Univ.) / Takayuki Kitasaka(Univ. of Hyogo) |
Assistant | Takahiro Ito(Hiroshima City Univ) / Natsuki Nakayama(Nagoya Univ.) / Takuya Nishikawa(National Cerebral and Cardiovascular Center Hospital) / Takeshi Hara(Gifu Univ.) / Yoshito Otake(NAIST) |
Paper Information | |
Registration To | Technical Committee on Healthcare and Medical Information Communication Technology / Technical Committee on Medical Imaging |
---|---|
Language | JPN |
Title (in Japanese) | (See Japanese page) |
Sub Title (in Japanese) | (See Japanese page) |
Title (in English) | A Study on Respiratory Rate Measurement Using Wearable CO2 Sensors |
Sub Title (in English) | |
Keyword(1) | Respiratory Rate |
Keyword(2) | CO2 sensor |
1st Author's Name | Mitsuhiro Fukuda |
1st Author's Affiliation | METS Inc.(METS) |
2nd Author's Name | Takunori Shimazaki |
2nd Author's Affiliation | Jikei University of Health Care Sciences(Jikei Univ.) |
3rd Author's Name | Daisuke Anzai |
3rd Author's Affiliation | Nagoya Institute of Technology(NIT) |
Date | 2022-11-18 |
Paper # | MICT2022-35,MI2022-64 |
Volume (vol) | vol.122 |
Number (no) | MICT-264,MI-265 |
Page | pp.pp.6-11(MICT), pp.6-11(MI), |
#Pages | 6 |
Date of Issue | 2022-11-11 (MICT, MI) |