Presentation 2020-07-21
Proposal of Non-invasive Blood Glucose Estimation Based on Bioelectromagnetic Response and Its Evaluation by Error Grid Analysis
Reo Takamatsu, Kenichi Higuchi, Dairoku Muramatsu,
PDF Download Page PDF download Page Link
Abstract(in Japanese) (See Japanese page)
Abstract(in English) Current blood glucose measurement requires invasive blood sampling from a patient. To reduce the patient's burden, we propose non-invasive blood glucose monitoring based on electromagnetic response (e.g., bioimpedance). Firstly, the electrical properties of blood phantom were evaluated as a function of glucose concentration at frequencies ranging from 1 kHz to 120 MHz. Secondly, bioimpedance variation caused by the change of blood glucose was estimated using a multi-layered wrist model. Thirdly, from simultaneous measurement of the blood glucose level and bioimpedance of the subjects, we confirmed a strong correlation between both of them. Finally, we derived an estimation formula of blood glucose based on bioimpedance. By error grid analysis, the formula was found to be clinically useful.
Keyword(in Japanese) (See Japanese page)
Keyword(in English) Blood glucose level / Wearable / Bioelectromagnetic response / Bioimpedance / Error grid analysis
Paper # WBS2020-5,MICT2020-4
Date of Issue 2020-07-14 (WBS, MICT)

Conference Information
Committee MICT / WBS
Conference Date 2020/7/21(1days)
Place (in Japanese) (See Japanese page)
Place (in English) Online
Topics (in Japanese) (See Japanese page)
Topics (in English) Wideband System, Healthcare and Medical Information Communication Technologies, etc.
Chair Eisuke Hanada(Saga Univ.) / Masanori Hamamura(Kochi Univ. of Tech.)
Vice Chair Hirokazu Tanaka(Hiroshima City Univ.) / Daisuke Anzai(Nagoya Inst. of Tech.) / Takashi Shono(INTEL) / Masahiro Fujii(Utsunomiya Univ.)
Secretary Hirokazu Tanaka(Kobe Univ.) / Daisuke Anzai(Yokohama National Univ.) / Takashi Shono(Okayama Univ. of Science) / Masahiro Fujii(National Defence Academy)
Assistant Keita Saku(Kyushu Univ.) / Kai Ishida(KISTEC) / Kento Takabayashi(Okayama Pref. Univ.) / Duong Quang Thang(NAIST) / Masafumi Moriyama(NICT) / Masayuki Kinoshita(Chiba Univ. of Tech.)

Paper Information
Registration To Technical Committee on Healthcare and Medical Information Communication Technology / Technical Committee on Wideband System
Language JPN
Title (in Japanese) (See Japanese page)
Sub Title (in Japanese) (See Japanese page)
Title (in English) Proposal of Non-invasive Blood Glucose Estimation Based on Bioelectromagnetic Response and Its Evaluation by Error Grid Analysis
Sub Title (in English)
Keyword(1) Blood glucose level
Keyword(2) Wearable
Keyword(3) Bioelectromagnetic response
Keyword(4) Bioimpedance
Keyword(5) Error grid analysis
1st Author's Name Reo Takamatsu
1st Author's Affiliation Tokyo University of Science(Tokyo Univ. of Science)
2nd Author's Name Kenichi Higuchi
2nd Author's Affiliation Tokyo University of Science(Tokyo Univ. of Science)
3rd Author's Name Dairoku Muramatsu
3rd Author's Affiliation Tokyo University of Science(Tokyo Univ. of Science)
Date 2020-07-21
Paper # WBS2020-5,MICT2020-4
Volume (vol) vol.120
Number (no) WBS-119,MICT-120
Page pp.pp.19-24(WBS), pp.19-24(MICT),
#Pages 6
Date of Issue 2020-07-14 (WBS, MICT)