Presentation | 2020-03-06 Influence of Magnetic Flux Density and Breaking Speed on Magnetic Blowout of DC Arc Discharge Hiroki Yamauchi, Hayato Watanabe, Koichiro Sawa, Kiyoshi Yoshida, |
---|---|
PDF Download Page | PDF download Page Link |
Abstract(in Japanese) | (See Japanese page) |
Abstract(in English) | The arc duration time ta and the arc energy Ea when a magnetic flux was applied to the electrical contact were measured. The effect of the magnetic blow-out was confirmed from the experimental results. The experimental conditions were as follows: the power supply voltage was DC100V, and the closing current Io was varied in the range of 0.5 to 30A. Electrical contact materials were tungsten (W) and silver (Ag). The magnetic flux density was set to 0 mT, 5 mT, and 10 mT, and the opening speed of the electrical contact was set to 25 mm/s, 50 mm/s, and 100 mm/s. As a result, ta was short when the magnetic flux was applied, while it was significantly long without the magnetic flux. However, it was confirmed that ta when the magnetic flux was applied becomes longer when Io is small. Therefore, it was presumed that the effect of magnetic blowing was reduced when the current was small. Furthermore, when the breaking speed was low, ta became longer |
Keyword(in Japanese) | (See Japanese page) |
Keyword(in English) | Magnetic Blowout / Electrical Contacts / Arc Duration / Arc Energy / Magnetic Flux Density / Breaking Speed |
Paper # | EMD2019-71 |
Date of Issue | 2020-02-28 (EMD) |
Conference Information | |
Committee | EMD |
---|---|
Conference Date | 2020/3/6(1days) |
Place (in Japanese) | (See Japanese page) |
Place (in English) | CHIBA Institute of Technology Tsudanuma Campus |
Topics (in Japanese) | (See Japanese page) |
Topics (in English) | Short NOTE |
Chair | Shinichi Wada(TMC System) |
Vice Chair | Yoshiki Kayano(Univ. of Electro-Comm.) |
Secretary | Yoshiki Kayano(Fuji Electric) |
Assistant | Yuichi Hayashi(NAIST) |
Paper Information | |
Registration To | Technical Committee on Electromechanical Devices |
---|---|
Language | JPN |
Title (in Japanese) | (See Japanese page) |
Sub Title (in Japanese) | (See Japanese page) |
Title (in English) | Influence of Magnetic Flux Density and Breaking Speed on Magnetic Blowout of DC Arc Discharge |
Sub Title (in English) | |
Keyword(1) | Magnetic Blowout |
Keyword(2) | Electrical Contacts |
Keyword(3) | Arc Duration |
Keyword(4) | Arc Energy |
Keyword(5) | Magnetic Flux Density |
Keyword(6) | Breaking Speed |
1st Author's Name | Hiroki Yamauchi |
1st Author's Affiliation | Nippon Institute of Technology(NIT) |
2nd Author's Name | Hayato Watanabe |
2nd Author's Affiliation | Nippon Institute of Technology(NIT) |
3rd Author's Name | Koichiro Sawa |
3rd Author's Affiliation | Nippon Institute of Technology(NIT) |
4th Author's Name | Kiyoshi Yoshida |
4th Author's Affiliation | Nippon Institute of Technology(NIT) |
Date | 2020-03-06 |
Paper # | EMD2019-71 |
Volume (vol) | vol.119 |
Number (no) | EMD-466 |
Page | pp.pp.61-64(EMD), |
#Pages | 4 |