Presentation | 2020-03-06 Influence of Ambient Gas on Breaking Arc Discharge of Electromagnetic contactor Sota Nagase, Yoshiki Yamamoto, Koichiro Sawa, Kiyoshi Yoshida, |
---|---|
PDF Download Page | PDF download Page Link |
Abstract(in Japanese) | (See Japanese page) |
Abstract(in English) | The electromagnetic contactor was opened and closed in air or in hydrogen. The arc duration ta, arc energy Ea, arc extinction current, contact resistance Rc, etc. were measured from the waveform of the breaking arc discharge. The power supply voltage was AC100V, 50Hz. The closed contact current Io was set at 10, 30 A, and the gas pressure was set at 0.5, 1, 3 atm. The effects of the ambient gas of Air and hydrogen (H2) on the characteristics of the arc were compared. As a result, it was confirmed that the arc duration time ta in the air was not affected by Io. The arc extinction current was about 1 A in air but became 3 A or more in hydrogen. Therefore, it was confirmed that the arc duration time ta in air was not affected by Io. On the other hand, in hydrogen, it became shorter when the ambient pressure was 3 atm. The arc extinction current was about 1 A in air but became 3A or more in hydrogen. Furthermore, it was found that the contact resistance Rc was smaller in hydrogen and more stable. |
Keyword(in Japanese) | (See Japanese page) |
Keyword(in English) | Electromagnetic contactor / Electrical Contact / Arc duration / Arc energy / Contact Resistance / Ambient Gas |
Paper # | EMD2019-72 |
Date of Issue | 2020-02-28 (EMD) |
Conference Information | |
Committee | EMD |
---|---|
Conference Date | 2020/3/6(1days) |
Place (in Japanese) | (See Japanese page) |
Place (in English) | CHIBA Institute of Technology Tsudanuma Campus |
Topics (in Japanese) | (See Japanese page) |
Topics (in English) | Short NOTE |
Chair | Shinichi Wada(TMC System) |
Vice Chair | Yoshiki Kayano(Univ. of Electro-Comm.) |
Secretary | Yoshiki Kayano(Fuji Electric) |
Assistant | Yuichi Hayashi(NAIST) |
Paper Information | |
Registration To | Technical Committee on Electromechanical Devices |
---|---|
Language | JPN |
Title (in Japanese) | (See Japanese page) |
Sub Title (in Japanese) | (See Japanese page) |
Title (in English) | Influence of Ambient Gas on Breaking Arc Discharge of Electromagnetic contactor |
Sub Title (in English) | Effect of Gas Pressure and Current |
Keyword(1) | Electromagnetic contactor |
Keyword(2) | Electrical Contact |
Keyword(3) | Arc duration |
Keyword(4) | Arc energy |
Keyword(5) | Contact Resistance |
Keyword(6) | Ambient Gas |
Keyword(7) | |
1st Author's Name | Sota Nagase |
1st Author's Affiliation | Nippon Institute of Technology(NIT) |
2nd Author's Name | Yoshiki Yamamoto |
2nd Author's Affiliation | Nippon Institute of Technology(NIT) |
3rd Author's Name | Koichiro Sawa |
3rd Author's Affiliation | Nippon Institute of Technology(NIT) |
4th Author's Name | Kiyoshi Yoshida |
4th Author's Affiliation | Nippon Institute of Technology(NIT) |
Date | 2020-03-06 |
Paper # | EMD2019-72 |
Volume (vol) | vol.119 |
Number (no) | EMD-466 |
Page | pp.pp.65-70(EMD), |
#Pages | 6 |
Date of Issue | 2020-02-28 (EMD) |