Presentation 2020-01-22
[Poster Presentation] Study on energy conversion in a traveling-wave thermoacoustic-system
Yuto Kawashima, Shin-ichi Sakamoto, Riku Onishi, Yuya Kurata, Kazuki Shiraki, Daichi Kuroki, Yoshiaki Watanabe,
PDF Download Page PDF download Page Link
Abstract(in Japanese) (See Japanese page)
Abstract(in English) In this report, the effect of the temperature distribution in the stack on the amount of the work flow generation was experimentally examined. In order to actively change the temperature distribution in the stack, a method of heating the center of a stack was used in which a heat source was installed not only at one end of the stack but also at the center of the stack. As a result, when the central heating method was used, the amount of the work flow generation increased by about 1.6 times compared to the method in which only one end of the stack was heated. This is thought to be due to the fact that a temperature gradient is also formed at the room temperature end due to the center heating of the stack, and the amount of energy generation at the room temperature end increases. From the above discussion, it is suggested that the stack center heating method is effective in increasing the work flow generation.
Keyword(in Japanese) (See Japanese page)
Keyword(in English) Stack / Temperature distribution / Work flow / Work source / Thermoacoustic / Energy
Paper # US2019-82
Date of Issue 2020-01-15 (US)

Conference Information
Committee EA / US
Conference Date 2020/1/22(2days)
Place (in Japanese) (See Japanese page)
Place (in English) Doshisha Univ.
Topics (in Japanese) (See Japanese page)
Topics (in English) [Joint Meeting on Acoustics and Ultrasonics Subsociety] Engineering/Electro Acoustics, Ultrasonics, and Related Topics
Chair Kenichi Furuya(Oita Univ.) / Jun Kondo(Shizuoka Univ.)
Vice Chair Suehiro Shimauchi(Kanazawa Inst. of Tech.) / Shigeto Takeoka(Shizuoka Inst. of Science and Tech.) / Shinichi Takeuchi(Toin Univ. of Yokohama) / Hikaru Miura(Nihon Univ.)
Secretary Suehiro Shimauchi(NHK) / Shigeto Takeoka(Univ. of Tokyo) / Shinichi Takeuchi(Kanagawa Univ.) / Hikaru Miura(Doshisha Univ.)
Assistant Keisuke Imoto(Ritsumeikan Univ.) / Daisuke Morikawa(Toyama Pref Univ.) / Mototaka Arakawa(Tohoku Univ.)

Paper Information
Registration To Technical Committee on Engineering Acoustics / Technical Committee on Ultrasonics
Language JPN
Title (in Japanese) (See Japanese page)
Sub Title (in Japanese) (See Japanese page)
Title (in English) [Poster Presentation] Study on energy conversion in a traveling-wave thermoacoustic-system
Sub Title (in English) Relationship between temperature distribution in a stack and amount of work flow generation
Keyword(1) Stack
Keyword(2) Temperature distribution
Keyword(3) Work flow
Keyword(4) Work source
Keyword(5) Thermoacoustic
Keyword(6) Energy
1st Author's Name Yuto Kawashima
1st Author's Affiliation Doshisha University(Dosisha Univ.)
2nd Author's Name Shin-ichi Sakamoto
2nd Author's Affiliation University of Shiga Prefecture(Univ. of Shiga Pref.)
3rd Author's Name Riku Onishi
3rd Author's Affiliation Doshisha University(Dosisha Univ.)
4th Author's Name Yuya Kurata
4th Author's Affiliation Doshisha University(Dosisha Univ.)
5th Author's Name Kazuki Shiraki
5th Author's Affiliation Doshisha University(Dosisha Univ.)
6th Author's Name Daichi Kuroki
6th Author's Affiliation Doshisha University(Dosisha Univ.)
7th Author's Name Yoshiaki Watanabe
7th Author's Affiliation Doshisha University(Dosisha Univ.)
Date 2020-01-22
Paper # US2019-82
Volume (vol) vol.119
Number (no) US-374
Page pp.pp.67-72(US),
#Pages 6
Date of Issue 2020-01-15 (US)