Presentation | 2020-01-22 [Poster Presentation] Study on energy conversion in a traveling-wave thermoacoustic-system Yuto Kawashima, Shin-ichi Sakamoto, Riku Onishi, Yuya Kurata, Kazuki Shiraki, Daichi Kuroki, Yoshiaki Watanabe, |
---|---|
PDF Download Page | PDF download Page Link |
Abstract(in Japanese) | (See Japanese page) |
Abstract(in English) | In this report, the effect of the temperature distribution in the stack on the amount of the work flow generation was experimentally examined. In order to actively change the temperature distribution in the stack, a method of heating the center of a stack was used in which a heat source was installed not only at one end of the stack but also at the center of the stack. As a result, when the central heating method was used, the amount of the work flow generation increased by about 1.6 times compared to the method in which only one end of the stack was heated. This is thought to be due to the fact that a temperature gradient is also formed at the room temperature end due to the center heating of the stack, and the amount of energy generation at the room temperature end increases. From the above discussion, it is suggested that the stack center heating method is effective in increasing the work flow generation. |
Keyword(in Japanese) | (See Japanese page) |
Keyword(in English) | Stack / Temperature distribution / Work flow / Work source / Thermoacoustic / Energy |
Paper # | US2019-82 |
Date of Issue | 2020-01-15 (US) |
Conference Information | |
Committee | EA / US |
---|---|
Conference Date | 2020/1/22(2days) |
Place (in Japanese) | (See Japanese page) |
Place (in English) | Doshisha Univ. |
Topics (in Japanese) | (See Japanese page) |
Topics (in English) | [Joint Meeting on Acoustics and Ultrasonics Subsociety] Engineering/Electro Acoustics, Ultrasonics, and Related Topics |
Chair | Kenichi Furuya(Oita Univ.) / Jun Kondo(Shizuoka Univ.) |
Vice Chair | Suehiro Shimauchi(Kanazawa Inst. of Tech.) / Shigeto Takeoka(Shizuoka Inst. of Science and Tech.) / Shinichi Takeuchi(Toin Univ. of Yokohama) / Hikaru Miura(Nihon Univ.) |
Secretary | Suehiro Shimauchi(NHK) / Shigeto Takeoka(Univ. of Tokyo) / Shinichi Takeuchi(Kanagawa Univ.) / Hikaru Miura(Doshisha Univ.) |
Assistant | Keisuke Imoto(Ritsumeikan Univ.) / Daisuke Morikawa(Toyama Pref Univ.) / Mototaka Arakawa(Tohoku Univ.) |
Paper Information | |
Registration To | Technical Committee on Engineering Acoustics / Technical Committee on Ultrasonics |
---|---|
Language | JPN |
Title (in Japanese) | (See Japanese page) |
Sub Title (in Japanese) | (See Japanese page) |
Title (in English) | [Poster Presentation] Study on energy conversion in a traveling-wave thermoacoustic-system |
Sub Title (in English) | Relationship between temperature distribution in a stack and amount of work flow generation |
Keyword(1) | Stack |
Keyword(2) | Temperature distribution |
Keyword(3) | Work flow |
Keyword(4) | Work source |
Keyword(5) | Thermoacoustic |
Keyword(6) | Energy |
1st Author's Name | Yuto Kawashima |
1st Author's Affiliation | Doshisha University(Dosisha Univ.) |
2nd Author's Name | Shin-ichi Sakamoto |
2nd Author's Affiliation | University of Shiga Prefecture(Univ. of Shiga Pref.) |
3rd Author's Name | Riku Onishi |
3rd Author's Affiliation | Doshisha University(Dosisha Univ.) |
4th Author's Name | Yuya Kurata |
4th Author's Affiliation | Doshisha University(Dosisha Univ.) |
5th Author's Name | Kazuki Shiraki |
5th Author's Affiliation | Doshisha University(Dosisha Univ.) |
6th Author's Name | Daichi Kuroki |
6th Author's Affiliation | Doshisha University(Dosisha Univ.) |
7th Author's Name | Yoshiaki Watanabe |
7th Author's Affiliation | Doshisha University(Dosisha Univ.) |
Date | 2020-01-22 |
Paper # | US2019-82 |
Volume (vol) | vol.119 |
Number (no) | US-374 |
Page | pp.pp.67-72(US), |
#Pages | 6 |
Date of Issue | 2020-01-15 (US) |