Presentation | 2019-12-13 Characteristics of break arcs blown-out in a 500VDC/10A circuit when moving range of arc spots is changed by shape of insulated silver pipes Taiju Masuda, Junya Sekikawa, |
---|---|
PDF Download Page | PDF download Page Link |
Abstract(in Japanese) | (See Japanese page) |
Abstract(in English) | Break arcs are generated and magnetically blown-out by transverse magnetic field in a 500VDC/10A resistive circuit. Silver electrical contacts are separated at constant opening speed. The contacts are covered with electrically insulated silver pipes. Using pipes, it is expected that motion of break arcs on side surfaces of the contacts will be restricted to make the shape of break arcs easy to analyze arc length. Arc lengthening time, the images of break arcs during occurring break arcs, and the length of break arcs just before are extinction are reported. Increasing the notch length of the silver pipe, increased the arc lengthening time and the arc length just before extinction. |
Keyword(in Japanese) | (See Japanese page) |
Keyword(in English) | Arc Discharge / Electrical Contacts / Electro-magnetic relay / High-speed camera |
Paper # | EMD2019-45 |
Date of Issue | 2019-12-06 (EMD) |
Conference Information | |
Committee | EMD |
---|---|
Conference Date | 2019/12/13(1days) |
Place (in Japanese) | (See Japanese page) |
Place (in English) | |
Topics (in Japanese) | (See Japanese page) |
Topics (in English) | |
Chair | Shinichi Wada(TMC System) |
Vice Chair | Yoshiki Kayano(Univ. of Electro-Comm.) |
Secretary | Yoshiki Kayano(Fuji Electric) |
Assistant | Yuichi Hayashi(NAIST) |
Paper Information | |
Registration To | Technical Committee on Electromechanical Devices |
---|---|
Language | JPN |
Title (in Japanese) | (See Japanese page) |
Sub Title (in Japanese) | (See Japanese page) |
Title (in English) | Characteristics of break arcs blown-out in a 500VDC/10A circuit when moving range of arc spots is changed by shape of insulated silver pipes |
Sub Title (in English) | |
Keyword(1) | Arc Discharge |
Keyword(2) | Electrical Contacts |
Keyword(3) | Electro-magnetic relay |
Keyword(4) | High-speed camera |
1st Author's Name | Taiju Masuda |
1st Author's Affiliation | Sizuoka University(Sizuoka Univ.) |
2nd Author's Name | Junya Sekikawa |
2nd Author's Affiliation | Sizuoka University(Sizuoka Univ.) |
Date | 2019-12-13 |
Paper # | EMD2019-45 |
Volume (vol) | vol.119 |
Number (no) | EMD-339 |
Page | pp.pp.13-18(EMD), |
#Pages | 6 |
Date of Issue | 2019-12-06 (EMD) |