Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
AP |
2024-03-14 15:15 |
Fukui |
UNIVERSITY OF FUKUI (Primary: On-site, Secondary: Online) |
[Invited Talk (Young Researcher)]
Study of non-contact PIM measurement systems for balanced transmission lines with electrically equivalent characteristics to microstrip lines Ryunosuke Murofushi (Yokohama Natl. Univ./Polytechnic Univ.), Nobuhiro Kuga (Yokohama Natl. Univ.), Eiji Hanayama (Polytechnic Univ.) AP2023-209 |
In many communication systems, passive intermoduration (PIM) is known as one of noises. The termination method standardi... [more] |
AP2023-209 pp.45-50 |
EST, MW, EMT, OPE, MWPTHz, IEE-EMT [detail] |
2023-07-21 14:25 |
Hokkaido |
Muroran Institute of Technology (Primary: On-site, Secondary: Online) |
Study of measurable distances in vital sign sensing using millimeter-wave radar Itsuki Iwata, Yuji Tanaka, Sakamoto Takuya (Kyoto Univ.) EMT2023-58 MW2023-76 OPE2023-58 EST2023-58 MWPTHz2023-54 |
Radar-based physiological measurement techniques detect the displacement of the body surface caused by respiration and h... [more] |
EMT2023-58 MW2023-76 OPE2023-58 EST2023-58 MWPTHz2023-54 pp.249-254 |
US |
2023-06-16 15:00 |
Kyoto |
Muromachi Campus, Doshisha University |
Ultrasonic Micro-Displacement Measurement System with Thermophone for Non-Contact Cardiac Pulse Monitoring Takaaki Asada, Shinichi Sasaki, Yuma Watabe (Murata Mfg. Co., Ltd.) US2023-13 |
Non-contact vital sign monitoring is expected to be used for medical applications or driver health monitoring. Airborne ... [more] |
US2023-13 pp.20-25 |
AP |
2023-04-14 13:20 |
Osaka |
Osaka Univ. (Primary: On-site, Secondary: Online) |
Evaluation of PIM correlation between the impedance matched method and the without termination method by using coupling compensation of transmission lines Ryunosuke Murofushi (YNU/PTU), Nobuhiro Kuga (YNU), Eiji Hanayama (PTU) AP2023-3 |
Without termination method is effective to reduce system size although PIM measurement is usually carried out by using I... [more] |
AP2023-3 pp.11-15 |
SCE |
2023-01-20 14:45 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. (Primary: On-site, Secondary: Online) |
Non-contacting Magnetostriction-Based Ultrasonic Guided Wave Testing Technique utilizing Magnetic Properties of STPG370 Pipes Yoshimi Hatsukade, Keisuke Watanabe, Kohei Okada, Ryohei Ohwa, Munkhnyam Temuulen, Wenxu Sun (Kindai Univ.) SCE2022-16 |
We have been developing a novel non-contacting magnetostriction-based ultrasonic guided wave testing technique, utilizin... [more] |
SCE2022-16 pp.17-22 |
MICT, MI |
2022-11-18 10:30 |
Aichi |
Nagoya Institute of Technology |
A Quantitative Study on AVF Thrill Using Non-Contact Measurement Takunori Shimazaki (Jikei Univ. of Health Sci.), Rumi Iwai (Hyogo Medical University Hosp.), Yoshifumi Kawakubo (Jikei Univ. of Health Sci.), Jun Mitsudou, Yuuhei Hayashi (Leimac), Shingo Ata (Osaka Met Univ.), Takeshi Yokoyama (Kyushu Univ.), Daisuke Anzai (Nagoya Tech Univ.) MICT2022-34 MI2022-63 |
An arteriovenous fistula (AVF) is a specialized vessel created by anastomosing arteriovenous vessels. Hemodialysis thera... [more] |
MICT2022-34 MI2022-63 pp.1-5 |
EST |
2022-05-19 15:45 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. (Primary: On-site, Secondary: Online) |
High-precision heart rate measurement for multiple people using array radar imaging and principal component analysis Itsuki Iwata, Takuya Sakamoto (Kyoto Univ.) EST2022-7 |
Millimeter-wave radar, which has a wide frequency bandwidth and a large number of array elements, has become increasingl... [more] |
EST2022-7 pp.34-37 |
MICT, EMCJ (Joint) |
2022-03-04 09:05 |
Online |
Online |
A Study on Non-contact Blood Pressure Estimation Method based on Subject Classification by Machine Learning Shuzo Ishizaka, Kohei Yamamoto, Tomoaki Ohtsuki (Keio Univ.) MICT2021-101 |
Non-contact Blood Pressure (BP) measurement is receiving a lot of interest for BP measurement on a daily basis.
To rea... [more] |
MICT2021-101 pp.1-6 |
SIS |
2022-03-04 11:30 |
Online |
Online |
Non-Contact Heart Rate Measurement based on Bispectrum Moushumi Tazen, Naoto Sasaoka, Kasumi Fujita, Yoshiharu Okamoto (Tottori Univ.) SIS2021-43 |
A Doppler radar has been acquired as a non-contact heartrate measurement method. Non-contact heartbeats measurement has ... [more] |
SIS2021-43 pp.68-71 |
EST |
2022-01-28 11:20 |
Online |
Online |
Non-contact Heart Rate Measurement Using Millimeter-wave Array Radar and Principal Component Analysis of Phase Sequence Itsuki Iwata, Takato Koda, Takuya Sakamoto (Kyoto Univ.) EST2021-84 |
In this study, we develop a novel method for the noncontact measurement of human heartbeat using ultra-wideband millimet... [more] |
EST2021-84 pp.136-139 |
NLP, MICT, MBE, NC (Joint) [detail] |
2022-01-23 11:45 |
Online |
Online |
A Novel Quantitative AVF Measurement Method Using Non-Contact Imaging Rumi Iwai (Hyogo College of Medicine), Takunori Shimazaki, Yoshifumi Kawakubo (Jikei Univ.), Masanobu Tsurumoto (Bunri Univ.), Hiroyuki Hayashi, Masaharu Tamaki (Tamaki-Aozora Hospital.), Aki Otsuka (Sugi Hospital.), Kei Fukami (Kurume Univ.), Shingo Ata (Osaka City Univ.), Daisuke Anzai (Nagoya Tech Univ.) NLP2021-125 MICT2021-100 MBE2021-86 |
Hemodialysis is a treatment where the blood is once sent out of the body and cleaned using a special filter called a dia... [more] |
NLP2021-125 MICT2021-100 MBE2021-86 pp.254-259 |
HPB (2nd) |
2021-09-28 15:50 |
Online |
Online |
Fundamental Study on Measurement of Electric field Around Electric wires with Piezoelectric film Shunkichi Takamatsu (NITTC), Takaya Yoshitake (UEC), Shinichiro Mito (NITTC) |
An inexpensive non-metal-contact voltage measurement has been attracting much attention, since voltage of a commercial p... [more] |
|
HIP, VRSJ |
2021-02-19 14:45 |
Online |
Online |
[Invited Talk]
Non-contact vital sign measurement Norihiro Sugita, Makoto Yoshizawa (Tohoku Univ.) HIP2020-89 |
Pulse wave obtained from a video (video plethysmography) can be used not only for health management but also for mental ... [more] |
HIP2020-89 pp.71-72 |
MICT, MI |
2020-11-04 14:20 |
Online |
Online |
Non-contact Blood Pressure Measurement using Doppler Radar based on Waveform Analysis by LSTM Shuzo Ishizaka, Kohei Yamamoto, Tomoaki Ohtsuki (Keio Univ.) MICT2020-15 MI2020-41 |
Recently, non-contact blood pressure measurement is receiving a lot of interests because it is suitable
for the blood p... [more] |
MICT2020-15 MI2020-41 pp.36-41 |
EMT, MW, OPE, EST, MWP, THz, IEE-EMT [detail] |
2020-07-17 09:55 |
Online |
Online |
Noncontact Measurement of the Propagation of a Heart Pulse Wave Using an Ultra-wideband Millimeter-wave Array Radar System Yuji Oyamada, Takuya Sakamoto (Kyoto Univ.) EMT2020-18 MW2020-27 OPE2020-13 EST2020-18 MWP2020-18 |
The velocity of a pulse wave is an important index used in detecting various diseases. In this paper, we carry out human... [more] |
EMT2020-18 MW2020-27 OPE2020-13 EST2020-18 MWP2020-18 pp.67-70 |
US |
2020-05-18 13:55 |
Online |
Online |
Non-contact measurement of viscoelasticity of rice cake by using focused airborne ultrasound Ryo Aoki, Marie Tabaru (Tokyo Tech) US2020-9 |
In the rice cake manufacturing process, race cake is only managed by the room temperature. For high precision management... [more] |
US2020-9 pp.7-11 |
NS, RCS (Joint) |
2019-12-20 13:55 |
Tokushima |
Tokushima Univ. |
Development of Telemetry System for Human Life Behavior, Breathing and Heart Rate in Nursing Facility Using 24GHz Band Radar Technology Kouki Momose, Kazuhiro Yamaguchi, Hideaki Matsue (SUS), Yasuaki Huruya (K C), Mituamasa Saito (CQ-S net) RCS2019-262 |
A telemetry system for human behavior, breathing and heart rate using both a 24 GHz band radar and Wi-Fi network without... [more] |
RCS2019-262 pp.133-138 |
SIP |
2019-08-30 10:25 |
Tokyo |
|
Development of Sway Angle Estimation for Crane with Digital Resonator and Its Field Experiment Naoki Horie, Masayoshi Nakamoto, Toru Yamamoto (Hiroshima Univ.) SIP2019-46 |
The cranes are well used in field such as transportation of load in construction field, factory and dock.
Since anti-s... [more] |
SIP2019-46 pp.35-40 |
US |
2019-02-22 10:55 |
Kanagawa |
|
Non-contact Acoustic Inspection Method for Concrete Structures
-- Long distance measurement for large bridge -- Itsuki Uechi, Tsuneyoshi Sugimoto, Kazuko Sugimoto, Shigeya Kawai (Toin Univ. of Yokohama), Noriyuki Utagawa, Chitose Kuroda (SatoKogyo Co., Ltd.), Akihiko Kawakami (JB Honshi Expressway) US2018-109 |
In this report, the measurement results of 2016 and 2017 on the lower surface of the floor slab of a large bridge were c... [more] |
US2018-109 pp.5-10 |
EA, US (Joint) |
2019-01-22 14:00 |
Kyoto |
Doshisha Univ. |
[Poster Presentation]
Basic study of measurement method of broadband ultrasonic attenuation in non-contact QUS Toshiaki Okubo, Shinnosuke Hirata, Hiroyuki Hachiya (TokyoTech) US2018-100 |
QUS is widely used as screenings of osteoporosis. In this study, a method of measurement of speed of sound (SOS) and bro... [more] |
US2018-100 pp.103-106 |