IEICE Technical Committee Submission System
Conference Schedule
Online Proceedings
[Sign in]
Tech. Rep. Archives
    [Japanese] / [English] 
( Committee/Place/Topics  ) --Press->
 
( Paper Keywords:  /  Column:Title Auth. Affi. Abst. Keyword ) --Press->

All Technical Committee Conferences  (Searched in: All Years)

Search Results: Conference Papers
 Conference Papers (Available on Advance Programs)  (Sort by: Date Descending)
 Results 1 - 20 of 46  /  [Next]  
Committee Date Time Place Paper Title / Authors Abstract Paper #
EMCJ 2024-01-19
14:25
Kumamoto   Experimental Verification of Impedance Balance Method for Reducing Radiated Emission of Three-Phase Inverters
Taiki Nishimoto, Yasuhiro Arai (Panasonic Industry) EMCJ2023-97
This report verifies the effectiveness in reducing radiated emission of three-phase inverters by impedance balance metho... [more] EMCJ2023-97
pp.55-60
EMCJ 2023-06-09
15:40
Hokkaido Otaru Chamber of Commerce & Industry
(Primary: On-site, Secondary: Online)
Reduction of common-mode voltage in three-phase inverter circuits considering mutual inductance of DC feeder lines
Makoto Fujimura, Tohlu Matsushima, Yuki Fukumoto (Kyutech), Kohei Takada, Koji Kobayashi (SANDEN) EMCJ2023-26
The impedance balancing method has been investigated as a method for reducing common mode voltage in three-phase inverte... [more] EMCJ2023-26
pp.70-75
MW 2023-03-02
14:55
Tottori Tottori Univ.
(Primary: On-site, Secondary: Online)
Microwave-DC Interconversion Using a Negative Resistance Oscillator with an FET
Kansei Maeda, Daiki Kiyama, Minoru Sanagi (Okayama Univ.) MW2022-166
When a packaged FET is operated in a common-drain mode, the negative resistance at the gate terminal is exhibited withou... [more] MW2022-166
pp.54-59
EMCJ 2023-01-27
16:10
Okayama WASHU BLUE RESORT
(Primary: On-site, Secondary: Online)
Common-Mode Current Reduction on Output Cable of Inverters with Impedance Balance Method
Taiki Nishimoto, Masahiro Yamaoka, Yasuhiro Arai (Panasonic Industry) EMCJ2022-90
This report presents a novel inverter circuit structure for suppressing common-mode (CM) current on output cable. Adding... [more] EMCJ2022-90
pp.99-104
EMCJ 2023-01-27
16:30
Okayama WASHU BLUE RESORT
(Primary: On-site, Secondary: Online)
Analysis of common-mode voltage during switching of individual IGBTs in three phase inverter
Makoto Fujimura, Tohlu Matsushima, Yuki Fukumoto (Kyutech), Kohei Takada, Koji Kobayashi (SANDEN) EMCJ2022-91
In recent years, the development of automated driving technology has led to the need for more reliable communication equ... [more] EMCJ2022-91
pp.105-110
EMCJ 2022-07-14
15:30
Tokyo
(Primary: On-site, Secondary: Online)
Method for estimating coupling to nearby a communication cable using common mode voltage/current distribution of the EV harness
Makoto Fujimura, Kyousuke Tanaka, Tohlu Matsushima, Yuki Fukumoto (KIT) EMCJ2022-32
Common mode currents flow on a power supply harnesses in an electric vehicle can be coupled to nearby a communication c... [more] EMCJ2022-32
pp.23-28
EMCJ 2022-06-10
09:30
Hokkaido Hokkaido University
(Primary: On-site, Secondary: Online)
Common-mode voltage reduction by controlling parasitic impedance around three-phase inverter circuit with consideration of load circuit
Taiki Kai, Tohlu Matsushima, Yuki Fukumoto, Kohei Takada, Koji Kobayashi (SANDEN) EMCJ2022-15
In recent years, as switching devices have increased in switching speed, electromagnetic disturbances generated from pow... [more] EMCJ2022-15
pp.5-10
EMCJ 2022-01-21
10:30
Online Online Termination Device for Mains Cable connected Outside of FAR -- Outline of HiZ-BoX and Validation method ( Part I : Common mode ) --
Toshio Chiyojima (JEITA), Hideki Takao (Panasonic Co.), Toshiro Tsubouchi (Murata Mfc.), Takashi Harada (Tokin EMC engineering Ltd.) EMCJ2021-62
Radiation emission measurements of electronic devices in a fully anechoic room are now available. However, it has been r... [more] EMCJ2021-62
pp.7-12
EMCJ 2022-01-21
15:45
Online Online Simple Method of Determining Chain-Parameter-Matrix Elements for Multi-Conductor Shielded Cable
Nobuo Kuwabara, Tohlu Matsushima, Yuki Fukumoto (KIT) EMCJ2021-71
Multiconductor shielded cables are used in vehicles and electronic devices to maintain EMC quality. A method using a cha... [more] EMCJ2021-71
pp.57-62
EE, OME, CPM 2021-11-18
11:35
Online Online Influence of Dispersion of Impedance among Each Phase of Motors on the Noise Reduction Effectiveness in the Noise Reduction Method Using Two Motors Operating in Opposite Phase
Toru Tsuruhisa, Yuki Abe, Yuichi Noge, Masahito Shoyama (Kyushu Univ.) EE2021-23 CPM2021-41 OME2021-17
An AC motor drive system using an inverter generates common mode noise. However,a common mode noise filter becomes bulky... [more] EE2021-23 CPM2021-41 OME2021-17
pp.29-34
MW 2020-06-04
14:50
Online Online A Microwave Oscillator with a Bipolar Transistor in Common-Collector Mode Controlled Negative Resistance
Hiroki Yamamoto, Minoru Sanagi (Okayama Univ.) MW2020-14
When a packaged bipolar transistor is operated in a common-collector mode, the negative resistance at the base is exhibi... [more] MW2020-14
pp.17-22
EMCJ, MICT
(Joint)
2020-03-13
16:30
Tokyo Kikai-Shinko-Kaikan Bldg.
(Cancelled but technical report was issued)
An Attempt of Error Term Reduction for Cross-Coupled-Transistor-Type Negative Impedance Converter for the Performance Improvement of Common-Mode Current Suppressor
Soichiro Kudo, Nishikata Atsuhiro, Soichiro Kudo (Tokyo Tech) EMCJ2019-96
Previously, a device for actively suppressing the common mode current was proposed, and a configuration using a cross-co... [more] EMCJ2019-96
pp.21-26
EMCJ, EMD, WPT, PEM
(Joint) [detail]
2019-07-19
14:05
Tokyo Kikai-Shinko-Kaikan Bldg. Calibration method of HiZ-BoX ( A termination device of AC mains in FAR) -- Comparison between the dipole antenna method and the TEM-CELL method --
Toshio Chiyojima (PFU) EMCJ2019-35 EMD2019-16
We had proposed HiZ-BoX which is a termination device of AC mains in FAR in the paper EMCJ-2018-99 last year, However th... [more] EMCJ2019-35 EMD2019-16
pp.31-35
EMCJ 2019-07-18
13:10
Tokyo Kikai-Shinko-Kaikan Bldg. Analysis of common-mode current using scale model for power line communication
Daiichiro Koike, Hiroyuki Okumura, Tohlu Matsushima, Yuki Fukumoto, Nobuo Kuwabara (Kyutech) EMCJ2019-22
Simulation and measurement by a scale model have been used to estimate radiation strength emitted from PLC (Power Line C... [more] EMCJ2019-22
pp.23-28
EMCJ 2019-05-10
15:35
Hyogo   Impedance Analysis of Brushless Motors by 3-D Electromagnetic Field Analysis and Equivalent Circuit Analysis
Yasuhiro Shiraki (Mitsubishi Electric) EMCJ2019-17
In power electric equipment, electromagnetic noise propagated via motors is a major factor in conductive noise. The cond... [more] EMCJ2019-17
pp.25-30
EMCJ 2019-04-12
10:20
Okinawa Okinawa Industry Support Center A Study on Common-mode Noise Reduction in Noncontact Biosignal Acquisition Circuit
Minghui Chen, Jianqing Wang, Daisuke Anzai (NIT), Georg Fischer, Jens Kirchner (FAU) EMCJ2019-11
Noncontact electrodes are a promising alternative to achieve a more comfortable and long-term biosignal recording. Howev... [more] EMCJ2019-11
pp.55-59
EMCJ, MICT
(Joint)
2019-03-15
14:20
Tokyo Kikai-Shinko-Kaikan Bldg. Effect on radiated emission measurement of termination devices for AC mains
Toshio Chiyojima (PFU) EMCJ2018-109
Although FAR (All Anechoic Chamber Anechoic chamber) is available as a radiation emission measurement site, it is pointe... [more] EMCJ2018-109
pp.11-16
EMCJ, MICT
(Joint)
2019-03-15
14:45
Tokyo Kikai-Shinko-Kaikan Bldg. Mode Conversion Parameters: LCL, TCL, Sdc, and Scd
Akira Sugiura (Kyoto Univ.), Tohlu Matsushima (Kyutech), Osami Wada (Kyoto Unv.) EMCJ2018-110
In wired telephone and LAN systems, a signal propagates in the differential mode along a pair of balanced wires. However... [more] EMCJ2018-110
pp.17-22
EMCJ 2017-11-22
15:15
Tokyo Kikai-Shinko-Kaikan Bldg. Non-Contact Measurement of Common Mode Load Impedance of Wire Harness upto High Frequencies based on Transmission Line Concept
Tomohiro Yoshikawa, Jianqing Wang (NIT), Yasunori Oguri, Makoto Tanaka, Michihira Iida (DENSO) EMCJ2017-73
Request to non-contact measurement method of load impedance connected to a wire harness is increasing rapidly.
A method... [more]
EMCJ2017-73
pp.51-56
WPT, EMCJ
(Joint)
2017-11-21
11:20
Tokyo Kikai-Shinko-Kaikan Bldg. Relation between parasitic coupling around power MOSFET and excitation of common-mode voltage
Tohlu Matsushima, Takao Kuroyanagi, Takashi Hisakado, Osami Wada (Kyoto Univ.) EMCJ2017-61
In this report, it is formalized that common-mode voltages are excited by switching current flows on parasitic capacitor... [more] EMCJ2017-61
pp.13-18
 Results 1 - 20 of 46  /  [Next]  
Choose a download format for default settings. [NEW !!]
Text format pLaTeX format CSV format BibTeX format
Copyright and reproduction : All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034)


[Return to Top Page]

[Return to IEICE Web Page]


The Institute of Electronics, Information and Communication Engineers (IEICE), Japan