Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
SIS, ITE-BCT |
2021-10-08 10:50 |
Online |
Online |
A Study on Contrast Enhancement of Images for SfM Kazuaki Takahashi, Masaaki Fujiyoshi (Tokyo Metro. Univ.) SIS2021-18 |
This paper investigates the application of contrast enhancement to photographs for structure from motion (SfM), where Sf... [more] |
SIS2021-18 pp.42-47 |
MI |
2021-03-16 13:30 |
Online |
Online |
Effect of Improving Versatility of Lung Nodules Classification Model by Fine-Tuning Taku Ri, Tatsuya Yamazaki (Niigata Univ.) MI2020-72 |
In order to improve the survival rate of lung cancer patients, it is important to detect nodules at an early stage, but ... [more] |
MI2020-72 pp.102-107 |
SANE |
2019-08-23 13:00 |
Tokyo |
Electric Navigation Research Institute |
Three-dimensional Reconstruction of Man-made Structures for Multibaseline Circular SAR Measurements Takuma Watanabe, Daisuke Ogawa, Yasuyuki Oishi (Fujitsu) SANE2019-38 |
Circular synthetic aperture radar (CSAR) is a microwave imaging technique which employs a circular flight trajectory of ... [more] |
SANE2019-38 pp.19-24 |
ITS, IE, ITE-AIT, ITE-HI, ITE-ME, ITE-MMS, ITE-CE [detail] |
2016-02-23 11:00 |
Hokkaido |
Hokkaido Univ. |
Development of Generation Method of Anaglyph Images without Ghost Artifacts based on Saliency and Local Warping for Objects Chiaki Kobayashi, Masashi Kameda, Prima Oky Dicky Ardiansyah (Iwate Prefectural Univ.) ITS2015-78 IE2015-120 |
Anaglyph is one of methods of stereoscopic image which can create the illusion of depth using 2-dimensional image. Howev... [more] |
ITS2015-78 IE2015-120 pp.253-258 |
MI |
2015-11-11 15:20 |
Nara |
NAIST |
Experimental report of three-dimensional measurement of muscle attachments in thigh muscles with two cadavers Norio Fukuda, Yoshito Otake, Futoshi Yokota (NAIST), Masaki Takao, Takeshi Ogawa, Keisuke Uemura, Nobuhiko Sugano (Osaka Univ.), Yoshinobu Sato (NAIST) MI2015-67 |
Muscle attachments are important for a bio-mechanical simulation. It is not easy to extract a patient-specific muscle at... [more] |
MI2015-67 pp.49-53 |
CPM |
2015-11-07 10:00 |
Niigata |
Machinaka Campus Nagaoka |
Improvement of angular dependence of magnetophotonic crystal for magneto-optic three-dimensional display Shoki Sakai, Kei Kudo, Kazuki Nakamura, Taichi Goto, Hiroyuki Takagi, Pang Boey Lim, Mitsuteru Inoue (TUT) CPM2015-96 |
We have developed a magneto-optic three-dimensional (3D) display using magnetophotonic crystals (MPCs). The MPC can incr... [more] |
CPM2015-96 pp.59-62 |
IE, ITE-ME, IPSJ-AVM, ITE-CE [detail] |
2015-08-03 10:30 |
Tokyo |
Tokyo Metropolitan Univ. |
Development of Generation Method of Anaglyph Images without Ghost Artifacts considering Saliency of Objects Chiaki Kobayashi, Masashi Kameda, Prima Oky Dicky Ardiansyah (Iwate Prefectural Univ.) IE2015-46 |
In the three-dimensional visualization, anaglyph image that is one of the simple stereoscopic methods produces the three... [more] |
IE2015-46 pp.1-6 |
SIP, EA, SP |
2015-03-03 10:45 |
Okinawa |
|
[Poster Presentation]
Design of 3D moving sound image with spherical parametric loudspeaker Daisuke Ikefuji, Masato Nakayama, Takanobu Nishiura, Yoichi Yamashita (Ritsumeikan Univ.) EA2014-116 SIP2014-157 SP2014-179 |
We have previously proposed the system with parametric loudspeakers for three-dimensional sound field reproduction.
It ... [more] |
EA2014-116 SIP2014-157 SP2014-179 pp.243-248 |
ET |
2015-01-31 13:00 |
Tokyo |
Mejiro Univ. |
Karate-kata Exercise Assist Method Using Video Image Retrieval Based on 3D Point Cloud Processing Kazumoto Tanaka (Kindai) ET2014-77 |
It is known that sport skill learning is facilitated by observing images of photographs of movements of trainees themsel... [more] |
ET2014-77 pp.29-32 |
IMQ |
2014-08-01 15:55 |
Toyama |
Univ. of Toyama |
Subjective Evaluation for Image Quality when the Background Region is Gray Scale in the case of Occurring the Coded Degradation for Background or Object Region of 3D CG Images with 8-Viewpoints Parallax Barrier Method Norifumi Kawabata, Masaru Miyao (Nagoya Univ.) IMQ2014-11 |
Until now, there have been many studies about image quality evaluation for multi-viewpoint 3D color still images or abou... [more] |
IMQ2014-11 pp.25-30 |
IMQ |
2014-05-16 15:20 |
Tokyo |
Takanawa Campus, Tokai University |
Evaluation Experiment for Subjective Image Quality in case of Occurring the Coded Degradation for Objects or Background Region of 3D CG Images with 8-Viewpoints Parallax Barrier Method Norifumi Kawabata, Masaru Miyao (Nagoya Univ.), Yuukou Horita (Univ. of Toyama) IMQ2014-6 |
Until now, there have been many studies about image quality for multi-viewpoint 3D still images. Particularly, as repres... [more] |
IMQ2014-6 pp.25-30 |
IMQ |
2013-12-13 15:25 |
Shizuoka |
Hamamatsu Campus, Shizuoka Univ. |
Comparison between subjective and objective evaluations using VSNR for 3-D image Kazuhiro Suzuki, Yuji Sakamoto (Hokkaido Univ.) IMQ2013-21 |
Some three-dimensional display technology has been noted. Various techniques are proposed and utilized for three-dimensi... [more] |
IMQ2013-21 pp.21-26 |
IMQ |
2013-12-13 15:50 |
Shizuoka |
Hamamatsu Campus, Shizuoka Univ. |
Statistical Analysis of Questionnaire Survey on the Evaluation of 3D Video Clips Norifumi Kawabata, Masaru Miyao (Nagoya Univ.) IMQ2013-22 |
Many studies have been conducted concerning visual fatigue and visually induced motion sickness induced by watching vide... [more] |
IMQ2013-22 pp.27-32 |
IMQ |
2013-05-17 14:45 |
Tokyo |
Seikei Univ. |
STATISTICAL ANALYSIS of SUBJECTIVE EVALUATION of 3D CG IMAGES with 8 VIEWPOINTS LENTICULAR LENS METHOD Norifumi Kawabata (Nagoya Univ.), Yuukou Horita (Univ. of Toyama) IMQ2013-4 |
Recently, we were able to watch 3D videos or movies with no glasses increasingly.
However, they are various for stereo... [more] |
IMQ2013-4 pp.19-24 |
MI |
2013-01-25 13:10 |
Okinawa |
Bunka Tenbusu Kan |
[Poster Presentation]
A Basic Study to Manipulate Volume Data of Brain Blood Vessel Using Its Position and Diameter Takuto Shiraishi, Toshihiro Shinohara, Noboru Nakasako (Kiniki Univ.), Masato Nakayama (Ritsumeikan Univ.) MI2012-105 |
In medical practice, doctors diagnose cerebrovascular disease by identifying a lesion from three-dimensionally reconstru... [more] |
MI2012-105 pp.227-230 |
IMQ |
2012-10-12 14:40 |
Kyoto |
Kyoto Institute of Technology, The Kosen Kaikan Faculty Club |
Image Quality Evaluation of Three-Dimensional CG Images with 8 Viewpoints Lenticular Lens Method for Occurring Coded Degradation at Certain Viewpoints Norifumi Kawabata, Keiji Shibata, Yasuhiro Inazumi, Yuukou Horita (Univ. of Toyama) IMQ2012-17 |
Image and video quality evaluation has become an increasingly crucial research topic with the development of multi-view ... [more] |
IMQ2012-17 pp.17-22 |
MVE, HI-SIG-VR |
2012-09-28 09:30 |
Hokkaido |
Two venues in Nemuro |
Absolute distance perception in a mixed reality environment using a binocular optical see-through head mounted display Makoto Yamauchi (AIST) MVE2012-40 |
Experiments to measure the absolute perceived distance of 3D computer graphics (CG) images were conducted using an optic... [more] |
MVE2012-40 pp.77-82 |
EID, ITE-IDY, IEE-EDD |
2012-01-28 11:09 |
Akita |
Akita University |
Three-dimensional imaging system by using a liquid crystal device with a variable focusing function Eiji Yumoto, Satoshi Oikawa, Hisasi Gotou, Marenori Kawamura (Akita Univ) EID2011-28 |
We propose a microscope system for continuously taking the magnification images of a three-dimensional object
by using ... [more] |
EID2011-28 pp.83-86 |
MI |
2012-01-19 11:20 |
Okinawa |
|
[Poster Presentation]
3D visualization of serial histological images of medaka and its comparison with MRM images Wataru Shoji, Tomohiro Ueno, Koji Sakai, Naozo Sugimoto (Kyoto Univ.) MI2011-85 |
In order to observe the structures inside medaka, we reconstruct 3D images of medaka from 2D images of serial histologic... [more] |
MI2011-85 pp.47-52 |
MI |
2012-01-19 14:40 |
Okinawa |
|
[Special Talk]
Computer-aided differential diagnosis of lung cancer using three-dimensional thoracic CT images Yoshiki Kawata, Noboru Niki (Tokushima Univ) MI2011-108 |
In the recent release of positive results from the National Lung Screening Trial (NLST) screening trial in the US showin... [more] |
MI2011-108 pp.171-172 |