IEICE Technical Committee Submission System
Conference Schedule
Online Proceedings
[Sign in]
Tech. Rep. Archives
    [Japanese] / [English] 
( Committee/Place/Topics  ) --Press->
 
( Paper Keywords:  /  Column:Title Auth. Affi. Abst. Keyword ) --Press->

All Technical Committee Conferences  (Searched in: All Years)

Search Results: Conference Papers
 Conference Papers (Available on Advance Programs)  (Sort by: Date Descending)
 Results 1 - 20 of 33  /  [Next]  
Committee Date Time Place Paper Title / Authors Abstract Paper #
EST 2021-01-21
09:35
Online Online Comparison of temperature rise in rat and human for whole-body exposure at 30 GHz
Sachiko Kodera (NIT), Kenji Taguchi (KIT), Akimasa Hirata (NIT) EST2020-53
Two international guidelines/standards for human protection from electromagnetic fields define the whole-body average sp... [more] EST2020-53
pp.1-5
EMCJ, MW, EST, IEE-EMC [detail] 2019-10-24
12:35
Miyagi Tohoku Gakuin University(Conf. Room 2, Eng. Bldg. 1) Fundamental Study on Whole Body Average SAR for Millimeter Wave Using the FDTD Method
Sachiko Kodera, Akimasa Hirata (NIT), Kenji Taguchi, Tatsuya Kashiwa (KIT) EMCJ2019-42 MW2019-71 EST2019-50
In the current international guidelines/standards for human protection from radio waves, the whole-body averaged specifi... [more] EMCJ2019-42 MW2019-71 EST2019-50
pp.33-37
AP, SANE, SAT
(Joint)
2019-07-19
09:00
Miyagi Tohoku Univ. Proposal of a Measurement Method for Complex Permittivity of a Lossy Liquid Using a Waveguide System
Nozomu Ishii, Yuya Aoki (Niigata Univ.), Yuto Shimizu, Tomoaki Nagaoka, Kanako Wake, Soichi Watanabe (NICT) AP2019-38
In a standard method for evaluating the specific absorption rate (SAR) of a mobile device, head phantom is formed by the... [more] AP2019-38
pp.89-94
EST 2018-09-06
10:55
Okinawa Kumejima-machi, Okinawa Temperature in the Human Brain for RF Exposure Considering the Vasodilation
Sachiko Kodera, Akimasa Hirata (NIT) EST2018-43
Two international guidelines/standards for human protection from electromagnetic fields define the specific absorption r... [more] EST2018-43
pp.5-9
EMCJ, IEE-SPC, EMD, PEM
(Joint) [detail]
2018-07-26
15:25
Tokyo Kikai-Shinko-Kaikan Bldg. On Determining the Fitting Range to Calibrate the SAR Probe Using the Waveguide System
Nozomu Ishii (NICT/Niigata Univ.), Yuto Shimizu, Tomoaki Nagaoka, Soichi Watanabe (NICT) EMCJ2018-19 EMD2018-17
In the measurement of the specific absorption rate (SAR) of the wireless mobile device, the electric field probe is scan... [more] EMCJ2018-19 EMD2018-17
pp.19-24
EMT, IEE-EMT 2018-05-25
15:00
Tokyo   Numerical Examination on Electromagnetic Wave in Multilayered Structure as Human Head Model
Thiri Su, Mitsuhiro Yokota (Univ. of Miyazaki) EMT2018-6
Human tissues are damaged because of the radiation when using mobile phone. The specific absorption rate (SAR) is widely... [more] EMT2018-6
pp.45-48
MWP 2018-05-18
14:35
Tokyo Kikai-Shinko-Kaikan Bldg. [Invited Talk] Assessment methods for radio protection with respect to advanced wireless systems
Teruo Onishi (NTT DOCOMO) MWP2018-1
Currently research and development as well as standardization on the 5th mobile communication system (5G) have been acti... [more] MWP2018-1
pp.1-6
EMT, EST, LQE, MWP, OPE, PEM, PN, IEE-EMT [detail] 2018-01-25
15:15
Hyogo   Variability and Difference of Thermal Time Constants in Human and Rat
Gomez-Tames Jose, Kodera Sachiko, Hirata Akimasa (Nitech) PN2017-63 EMT2017-100 OPE2017-141 LQE2017-123 EST2017-99 MWP2017-76
In the international guidelines/standards, the specific absorption rate (SAR) averaged over 10 g of tissue is used as a ... [more] PN2017-63 EMT2017-100 OPE2017-141 LQE2017-123 EST2017-99 MWP2017-76
pp.137-142
MW, EMCJ, EST, IEE-EMC [detail] 2017-10-19
15:00
Akita Yupopo Comparison of Thermal Response between Rat and Human for Exposure from Dipole Antenna
Sachiko Kodera, Akimasa Hirata (Nagoya Inst. of Tech.) EMCJ2017-36 MW2017-88 EST2017-51
In the international guidelines/standards, the specific absorption rate (SAR) averaged over 10 g of tissue is used as a ... [more] EMCJ2017-36 MW2017-88 EST2017-51
pp.55-59
EST 2016-09-09
09:10
Okinawa Ishigakishi-Shoko-Kaikan Analysis of Temperature Rise in Rats for Localized Microwave Exposure at 10 GHz Band
Sachiko Kodera, Ryota Morimoto, Akimasa Hirata (NIT), Hiroshi Masuda (Kurume Univ.), Takuji Arima (Tokyo Univ. Agr. & Tech.), Soichi Watanabe (NICT) EST2016-47
In safety guidelines, the specific absorption rate (SAR) averaged over a specific volume is used as a metric for human p... [more] EST2016-47
pp.219-223
EMCJ, EMD 2016-07-15
14:55
Tokyo Kikai-Shinko-Kaikan Bldg. An Investigation on SAR Measurement Method for MHz-Band Wireless Power Transfer Systems
Satoshi Shimoyama (TUAT), Jerdvisanop Chakarothai, Kanako Wake, Lira Hamada (NICT), Takuji Arima, Toru Uno (TUAT), Soichi Watanabe (NICT) EMCJ2016-46 EMD2016-19
In this paper, we construct a measurement system and propose an experiment-based evaluation method for assessing specifi... [more] EMCJ2016-46 EMD2016-19
pp.13-18
EMCJ 2015-11-13
11:25
Kanagawa Mitsubishi Electric Corporation Specific Absorption Rate Measurement for Base Station Antennas
Takahiro Iyama, Teruo Onishi, Yoshiaki Tarusawa (NTT DOCOMO), Lira Hamada, Soichi Watanabe (NICT) EMCJ2015-83
The SAR (Specific Absorption Rate) measurement procedure is mainly used for mobile handsets and so on. Applicability of ... [more] EMCJ2015-83
pp.13-17
EMCJ 2015-04-28
13:05
Tochigi Utsunomiya Univ. Measurement System Validation for Specific Absorption Rate of Mobile Wireless Device -- Design of the Reference Antenna for the System Validation --
Lira Hamada, Soichi Watanabe (NICT), Jianqing Wang (NIT), Masaharu Takahashi (Chiba Univ.), Yoshitsugu Kamimura (Utsunomiya Univ.), Nozomu Ishii (Niigata Univ.), Teruo Onishi (NTT DOCOMO) EMCJ2015-1
The SAR reference values by standard dipole antennas for the performance validation of the measurement equipment are des... [more] EMCJ2015-1
pp.1-4
EMCJ, WPT
(Joint)
2015-01-22
16:40
Okinawa Okinawaken Jichikaikan Compliance Assessment Method of Wireless Power Transfer System at 6 MHz Band
Tetsu Sunohara, Akimasa Hirata (NIT), Teruo Onishi (NTT DOCOMO) EMCJ2014-91
There has been an increasing concern toward realizing wireless power transfer systems. Recently, several studies have re... [more] EMCJ2014-91
pp.35-38
EMCJ, EST 2014-09-12
14:25
Hokkaido Kitami Inst. Technology Variability of Temperature Elevation in the Head Models Due to Dipole Antenna -- Adopting Measured Blood Flow Rate --
Shunya Ota, Ilkka Laakso, Akimasa Hirata, Osamu Fujiwara (Nagoya Inst. of Tech.) EMCJ2014-39 EST2014-53
Specific absorption rate (SAR) is used as a metric for human protection from microwave exposure although biological effe... [more] EMCJ2014-39 EST2014-53
pp.47-51
MW 2014-06-26
14:00
Aichi Toyohashi Univ. of Tech. Compliance Assessment Method of Wireless Power Transfer System with Induction Coupling at 100 kHz Band
Tetsu Sunohara, Akimasa Hirata (Nagoya Inst. of Tech.), Teruo Onishi (NTT DOCOMO) MW2014-49
There has been an increasing concern about the realization of wireless power transfer system. Recently, several studies ... [more] MW2014-49
pp.41-44
EMCJ, IEE-EMC 2013-12-20
13:55
Aichi Denso co. Quantification of Whole-body Average SAR for Small Animals in Reverberation-Chamber-Type Whole-Body Exposure System
Jingjing Shi (Nagoya Inst. of Tech.), Jerdvisanop Chakarothai (NICT), Jianqing Wang (Nagoya Inst. of Tech.), Kanako Wake, Soichi Watanabe (NICT), Osamu Fujiwara (Nagoya Inst. of Tech.) EMCJ2013-106
This paper aims to perform a verification study for a hybrid approach and to achieve a high-quality exposure level quant... [more] EMCJ2013-106
pp.31-36
EMCJ 2013-01-10
10:30
Nagasaki Nagasaki Univ. Correlation between Peak SAR and Maximum Temperature Elevation Due to Dipole Antenna at 0.5-10GHz
Ryuichi Asai, Ilkka Laakso, Akimasa Hirata (Nagoya Inst.) EMCJ2012-103
Specific absorption rate (SAR) is used as a metric for human protection from radio-frequency exposure although biologica... [more] EMCJ2012-103
pp.7-11
EMCJ, IEE-EMC 2012-12-14
09:05
Gifu Gifu Univ. Numerical Dosimetry of Small Animal in Reverberation Chamber
Jerdvisanop Chakarothai, Jianqing Wang, Osamu Fujiwara (NIT), Kanako Wake, Soichi Watanabe (NICT) EMCJ2012-86
As an evaluation method of the specific absorption rate (SAR) of biological bodies inside a reverberation chamber (RC) w... [more] EMCJ2012-86
pp.1-6
MW 2012-10-19
14:40
Tochigi Utsunomiya Univ. On Numerical Dosimetry for Human Model due to Wireless Power Transmission with Magnetic Resonance
Shogo Tsuchida, Ilkka Laakso, Akimasa Hirata (NICT) MW2012-109
The present study discusses a fast computational method for calculating the specific absorption rate (SAR) due to magnet... [more] MW2012-109
pp.157-162
 Results 1 - 20 of 33  /  [Next]  
Choose a download format for default settings. [NEW !!]
Text format pLaTeX format CSV format BibTeX format
Copyright and reproduction : All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034)


[Return to Top Page]

[Return to IEICE Web Page]


The Institute of Electronics, Information and Communication Engineers (IEICE), Japan