Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
MI, MICT |
2023-11-14 11:10 |
Fukuoka |
|
[Short Paper]
Choroid layer extraction for 3D OCT images using a deep learning network fusing CNN and Transformer Shingo Tamachi, Takayuki Okamoto, Takehito Iwase, Yuto Kawamata, Hirotaka Yokouchi, Hideaki Haneishi (Chiba Univ.) MICT2023-28 MI2023-21 |
The choroid, a dense vascular layer located in the fundus, accounts for the majority of the blood supply to the retina. ... [more] |
MICT2023-28 MI2023-21 pp.13-14 |
MI |
2023-03-07 17:42 |
Okinawa |
OKINAWA SEINENKAIKAN (Primary: On-site, Secondary: Online) |
[Short Paper]
Choroid Extraction from 3D OCT Images by A Deep Learning Model Shingo Tamachi, Takehito Iwase, Hirotaka Yokouchi, Takayuki Okamoto, Hideaki Haneishi (Chiba Univ.) MI2022-129 |
The choroid is a dense vascular layer located in the fundus. In recent years, clinical studies have shown an association... [more] |
MI2022-129 pp.221-222 |
MI |
2020-01-30 09:30 |
Okinawa |
OKINAWAKEN SEINENKAIKAN |
Development of OCT Simulator using KTN Wavelength Swept Light Source. Masashi Nakamura, Kazumi Murata, Koichi Ogawa (Hosei Univ.) MI2019-96 |
Optical Coherence Tomography (OCT) is used to acquire tomographic images in the retina of an eye. This is an imaging dev... [more] |
MI2019-96 pp.141-145 |
MI |
2020-01-30 09:40 |
Okinawa |
OKINAWAKEN SEINENKAIKAN |
[Short Paper]
A Combined System of Raman Spectroscopy and Optical Coherence Tomography for Pathological Diagnosis Yumi Ueda, Kazuya Nakano, Takashi Ohnishi, Hanako Tatekawa, Seiichiro Hirono, Yasuo Iwadate, Hideaki Haneishi (Chiba Univ.) MI2019-97 |
Pathological diagnosis during surgery is performed to determine the area which have to be removed. Although it can be pe... [more] |
MI2019-97 pp.147-148 |
PRMU, BioX |
2019-03-17 10:45 |
Tokyo |
|
Study on Detection of Intravascular Lipid-Rich Plaque in Cardiovascular OCT Image Takaya Kominami, Haiyuan WU (Wakayama Univ.), Takashi Kubo (Wakayama Medical Univ.) BioX2018-36 PRMU2018-140 |
Optical Coherence Tomography (OCT) is an image diagnostic device capable of displaying a short-axis cross-sectional imag... [more] |
BioX2018-36 PRMU2018-140 pp.43-48 |
MI |
2018-07-24 10:15 |
Iwate |
aiina (Morioka, Iwate) |
Classification of Corneal Shape Images by Machine Learning Yuji Ayatsuka (CRESCO), Kazutaka Kamiya (Kitasato Univ.), Yudai Kato, Yusuke Kudo (CRESCO), Fusako Fujimura, Nobuyuki Shoji (Kitasato Univ.), Yosai Mori, Kazunori Miyata (Miyata Eye Hospital) MI2018-22 |
Keratoconus is one of an ophthalmic disease on a cornea, which brings thinning and deformation in the center of cornea a... [more] |
MI2018-22 pp.5-8 |
QIT (2nd) |
2017-11-16 13:50 |
Saitama |
Saitama University |
[Poster Presentation]
Transverse resolution improvement in quantum optical coherence tomography Yoko Kawaguchi, Kyohei Hayama, Ryo Okamoto (Kyoto Univ.), Norihiko Nishizawa (Nagoya Univ.), Shigeki Takeuchi (Kyoto Univ.) |
Quantum optical coherence tomography (QOCT), a quantum version of optical coherence tomography (OCT), has been proposed ... [more] |
|
US |
2017-10-05 13:25 |
Miyagi |
|
Improvement of High Frequency Ultrasound Images by Point Spread Function Obtained with Optical Coherence Tomography Naoshi Kashiwagura, Ryo Nagaoka (Tohoku Univ), Kazuto Kobayashi (HONDA ELECTRONICS), Yoshihumi Saijo (Tohoku Univ) US2017-57 |
A novel skin imaging combining ultrasound and optical coherence tomography (OCT) is proposed in the present study. Point... [more] |
US2017-57 pp.5-10 |
IT, SIP, RCS |
2017-01-19 16:10 |
Osaka |
Osaka City Univ. |
Source Estimation of en-face OCT by Sparse Signal Modeling Takumi Kawamura, Shunpei Ito, Shogo Muramatsu, Samuel Choi (Niigata Univ.) IT2016-79 SIP2016-117 RCS2016-269 |
This work proposes a perform source estimation method of en-face optical coherence tomography (OCT)
through sparse sign... [more] |
IT2016-79 SIP2016-117 RCS2016-269 pp.195-200 |
PRMU, IE, MI, SIP |
2016-05-19 14:40 |
Aichi |
|
Stent Identification of Circulatory Organ OCT Image Koki Wada, Haiyuan Wu, Kazumasa Suzuki (Wakayama Univ), Takashi Akasaka, Takashi Kubo (Wakayama Medical Univ) SIP2016-7 IE2016-7 PRMU2016-7 MI2016-7 |
In recent years, OCT (Optical Coherence Tomography) has being used to diagnosis the illness in blood vessel.OCT is an im... [more] |
SIP2016-7 IE2016-7 PRMU2016-7 MI2016-7 pp.31-36 |
OFT, OCS, OPE (Joint) [detail] |
2016-02-19 10:50 |
Okinawa |
Okinawa Univ. |
High stability measurement by simple OCT for skin Sae Tabuchi, Tatsuo Shiina (Chiba Univ.) OCS2015-111 OFT2015-66 OPE2015-231 |
Simple OCT (Optical Coherence Tomography) for human skin was designed and developed to measure and to evaluate skin in v... [more] |
OCS2015-111 OFT2015-66 OPE2015-231 pp.61-66(OCS), pp.61-66(OFT), pp.87-92(OPE) |
MI |
2016-01-19 14:05 |
Okinawa |
Bunka Tenbusu Kan |
[Special Talk]
Development of retinal OCT system and its clinical application in ophthalmology Masahiro Akiba (Topcon/Riken) MI2015-97 |
Optical coherence tomography (OCT) is a widely known cross-sectional imaging modality which performs micrometer-scale, c... [more] |
MI2015-97 pp.113-116 |
MI |
2016-01-20 13:05 |
Okinawa |
Bunka Tenbusu Kan |
Semi-automatic extraction method of calcified plaque from coronary computed tomography angiography image Yuki Yoshida (Yamagata Univ.), Koki Shibuya (Nihonkai General Hospital), Kei Sasaki, Takaaki Horii, Tetsuya Yuasa (Yamagata Univ.) MI2015-132 |
CCTA (Coronary Computed Tomography Angiography) offers not only diagnostic capability matching that of CAG (Coronary Ang... [more] |
MI2015-132 pp.289-294 |
QIT (2nd) |
2015-05-25 13:20 |
Osaka |
Osaka University |
[Poster Presentation]
Study on the rapid imaging of quantum optical coherence tomography Shun Suezawa, Masayuki Okano, Ryo Okamoto (Kyoto Univ.), Norihiko Nishizawa (Nagoya Univ.), Shigeki Takeuchi (Kyoto Univ.) |
Quantum optical coherence tomography (QOCT), a quantum version of optical coherence tomography (OCT ), has been studied ... [more] |
|
PRMU, MI, IE, SIP |
2015-05-15 10:00 |
Mie |
|
On Application of NSOLT to 3-D OCT Data Denoising Takumi Kawamura, Sho Wakasugi, Zhiyu Chen, Shogo Muramatsu, Samuel Choi (Niigata Univ.) SIP2015-19 IE2015-19 PRMU2015-19 MI2015-19 |
This report proposes 3-D OCT data denoising with non-separable oversampled lapped transform (NSOLT), which the authors p... [more] |
SIP2015-19 IE2015-19 PRMU2015-19 MI2015-19 pp.99-104 |
PRMU, BioX |
2015-03-19 10:30 |
Kanagawa |
|
Automatic Detection and Position Estimation of Stent from OCT Image of Circulatory Organ Mineyuki Tsuda, Haiyuan Wu (Wakayama Univ.) BioX2014-45 PRMU2014-165 |
In recent years, Optical Coherence Tomography (OCT) has been used extensively in the medical field.
However, there is n... [more] |
BioX2014-45 PRMU2014-165 pp.35-40 |
IE, ITS, ITE-AIT, ITE-HI, ITE-ME, ITE-MMS, ITE-CE [detail] |
2015-02-23 10:00 |
Hokkaido |
Hokkaido Univ. |
Numerical analysis of optical tomographic imaging using virtual phase conjugation Yuta Goto, Atsushi Okamoto, Atsushi Shibukawa, Akihisa Tomita (Hokkaido Univ.) |
We propose a new optical tomographic imaging using phase conjugation technique through the virtual optics. This technolo... [more] |
|
QIT (2nd) |
2014-05-12 10:30 |
Aichi |
Nagoya Univ. |
Demonstration of high-resolution quantum optical coherence tomography by broadband frequency-correlated photon pairs Masayuki Okano, Yuichi Nagamatsu, Akira Tanaka (Hokkaido Univ./Osaka Univ.), Hwan Hong Lim (NIMS), Ryo Okamoto (Hokkaido Univ./Osaka Univ.), Norihiko Nishizawa (Nagoya Univ.), Sunao Kurimura (NIMS), Shigeki Takeuchi (Hokkaido Univ./Osaka Univ./Kyoto Univ.) |
Optical coherence tomography (OCT) based on low-coherence light interference has widely been utilized in medicine as a n... [more] |
|
MI |
2014-01-26 13:30 |
Okinawa |
Bunka Tenbusu Kan |
Registration Algorithm of Fundus Oculi for 3-D Optical Coherence Tomography Images Kyosuke Togashi, Miki Sakamoto (Yamagata Univ.), Gaku Takeuchi, Masahiro Akiba (TOPCON), Takeshi Yabana, Kazuko Omodaka, Morin Ryu, Wataru Kobayashi, Yu Yokoyama (Tohoku Univ.), Yasufumi Fukuma (TOPCON), Toru Nakazawa, Tetsuya Yuasa (Tohoku Univ.) MI2013-80 |
Recently, retinal nerve fiber layer (RNFL) thickness measurement from retinal optical coherence tomography (OCT) images ... [more] |
MI2013-80 pp.133-137 |
MWP |
2013-04-26 10:15 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
Terahertz Imaging Using Frequency Domain Optical-Coherence-Tomography Techniques Toshiyuki Ikeo, Takayuki Isogawa (Osaka Univ.), Katsuhiro Ajito, Naoya Kukutsu (NTT), Tadao Nagatsuma (Osaka Univ.) MWP2013-1 |
In order to realize the non-destructive and non-contact inspection of objects by using terahertz (THz) waves, we propose... [more] |
MWP2013-1 pp.1-6 |