Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
MI, MICT |
2023-11-14 11:10 |
Fukuoka |
|
[Short Paper]
Choroid layer extraction for 3D OCT images using a deep learning network fusing CNN and Transformer Shingo Tamachi, Takayuki Okamoto, Takehito Iwase, Yuto Kawamata, Hirotaka Yokouchi, Hideaki Haneishi (Chiba Univ.) MICT2023-28 MI2023-21 |
The choroid, a dense vascular layer located in the fundus, accounts for the majority of the blood supply to the retina. ... [more] |
MICT2023-28 MI2023-21 pp.13-14 |
CCS, NLP |
2022-06-09 14:55 |
Osaka |
(Primary: On-site, Secondary: Online) |
Basic Performance of CNNs Using Dynamic Filters Based on Octave Convolution Kiyotaka Matono, Hidehiro Nakano (Tokyo City Univ.) NLP2022-5 CCS2022-5 |
The methods of using dynamic filters for convolutional neural networks (CNNs) have attracted attentions. In recent years... [more] |
NLP2022-5 CCS2022-5 pp.23-26 |
MI, MICT [detail] |
2021-11-05 10:45 |
Online |
Online |
[Short Paper]
A Method for Extracting and Visualizing Calcified Areas from Coronary OCT Images. Ryo Oikawa, Toru Kato, Akio Doi (Iwate Prefectural Univ.), Masaru Ishida (Iwate Medical Univ.) MICT2021-32 MI2021-30 |
Optical coherence tomography (OCT) has been widely used to diagnose calcified areas in coronary arteries in the last dec... [more] |
MICT2021-32 MI2021-30 pp.22-25 |
MI |
2021-07-08 14:30 |
Online |
Online |
Extraction of Calcified Regions from OCT Images Using Deep Learning Ryo Oikawa, Toru Kato, Akio Doi, Basabi Chakraborty (Iwate Prefectural Univ.), Masaru Ishida (Iwate Medical Univ.) MI2021-12 |
Stenosis or occlusion of coronary arteries leads to angina attacks and myocardial infarctions, and coronary artery disea... [more] |
MI2021-12 pp.15-19 |
PRMU, IPSJ-CVIM |
2021-03-04 16:05 |
Online |
Online |
Media detection from cardiovascular OCT images based on deep learning jiwei zhang, kai wang (wakayama univ), Takashi Kubo (Wakayama Medical Univ), haiyuan wu (wakayama univ) PRMU2020-80 |
Medical image segmentation is an important issue in determining whether medical images can provide reliable evidence in ... [more] |
PRMU2020-80 pp.65-70 |
MVE, IMQ, IE, CQ (Joint) [detail] |
2021-03-03 09:20 |
Online |
Online |
Study of Environment Recognition and 3D Map Generation Using SegNet for Night Forest Monitoring Using an Environmental Monitoring Robot Takeo Kaneko (WASEDA Univ.), Junji Yamato (Kogakuin Univ.), Hiroyuki Ishii, Jun Ohya, Atuo Takanishi (WASEDA Univ.) IMQ2020-29 IE2020-69 MVE2020-61 |
Towards the actualization of autonomous robots that monitor forests, around which various kinds of damages caused by wil... [more] |
IMQ2020-29 IE2020-69 MVE2020-61 pp.91-96 |
OPE, OCS, LQE |
2020-10-23 15:05 |
Online |
Online |
[Invited Talk]
Widely tunable MEMS based high speed swept VCSEL source operating over a wide temperature for SS-OCT Mohammed Saad Khan, Changdae Keum (Santec Corporation), Nobuhiko Nishiyama (Tokyo Institute of Technology) OCS2020-18 OPE2020-41 LQE2020-21 |
We present a Micro Electro Mechanically Systems (MEMS) based tunable Vertical Cavity Surface Emitting Laser (VCSEL) for ... [more] |
OCS2020-18 OPE2020-41 LQE2020-21 pp.54-56 |
MI |
2020-01-29 13:20 |
Okinawa |
OKINAWAKEN SEINENKAIKAN |
[Short Paper]
Retinal nerve fiber layer analysis on fundus images using CNN trained with OCT data Ryusuke Watanabe (Gifu Univ.), Chisako Muramatsu (Shiga Univ.), Akira Sawada, Xiangrong Zhou (Gifu Univ.), Yuji Hatanaka (USP), Takeshi Hara, Tetsuya Yamamoto, Hiroshi Fujita (Gifu Univ.) MI2019-80 |
Glaucoma is the first leading cause of blindness in Japan. However, glaucoma only has a few warning signs or symptoms. T... [more] |
MI2019-80 pp.71-72 |
MI |
2020-01-30 09:30 |
Okinawa |
OKINAWAKEN SEINENKAIKAN |
Development of OCT Simulator using KTN Wavelength Swept Light Source. Masashi Nakamura, Kazumi Murata, Koichi Ogawa (Hosei Univ.) MI2019-96 |
Optical Coherence Tomography (OCT) is used to acquire tomographic images in the retina of an eye. This is an imaging dev... [more] |
MI2019-96 pp.141-145 |
PRMU, MI, IPSJ-CVIM [detail] |
2019-09-05 13:55 |
Okayama |
|
Hierarchical Classification to Detect Type of Diseases and Abnormality Simultaneously in Optical Coherence Tomography Images Yudai Kato, Yuji Ayatsuka, Takaki Uta (CRESCO), Soichiro Kuwayama, Hideaki Usui, Aki Kato, Yuichiro Ogura, Tsutomu Yasukawa (Nagoya City University) PRMU2019-26 MI2019-45 |
Analyzing medical images with machine learning is useful not only
for classifying types of diseases but for screening ... [more] |
PRMU2019-26 MI2019-45 pp.105-108 |
MI |
2019-01-22 14:35 |
Okinawa |
|
Research on macular analysis based on OCT angiography image analysis Shinnosuke Yamaoka, Shinya Fukumoto, Masayuki Kashima, Kiminori Sato, Mutsumi Watanabe, Hideki Shiihara, Syozo Sonoda, Taiji Sakamoto (Kagoshima Univ.) MI2018-81 |
The purpose of this study is to ascertain whether the complexity of the shape of macular region obtained from OCT angiog... [more] |
MI2018-81 pp.87-92 |
OFT |
2018-10-11 14:00 |
Miyagi |
Touhoku Univ. |
[Poster Presentation]
Three dimensional imaging of biological tissues using multimode fiber for optical communications Eto Kai, Junpei Masuta (Yamagata Univ.), Izumi Nishidate (Tokyo Univ. of Agriculture and Technology), Manabu Sato (Yamagata Univ.) OFT2018-24 |
The graded-index short multimode fiber (GI SMMF) for optical communications has been investigated for the application to... [more] |
OFT2018-24 pp.51-56 |
EMD, LQE, OPE, CPM, R |
2018-08-23 15:20 |
Hokkaido |
Otaru Camber of Commerce & Industry |
Coherence Length Extension Effect of Swept Light Source by Constant Output Power Control Masahiro Ueno, Mingchen Chen, Seiji Toyoda, Takashi Sakamoto, Yuichi Akage, Joji Yamaguchi, Tadashi Sakamoto (NTT) R2018-22 EMD2018-25 CPM2018-25 OPE2018-52 LQE2018-41 |
Swept source optical coherence tomography (SS-OCT) is a technique to capture tomographic images of moving objects at hig... [more] |
R2018-22 EMD2018-25 CPM2018-25 OPE2018-52 LQE2018-41 pp.25-30 |
MI |
2018-07-24 10:15 |
Iwate |
aiina (Morioka, Iwate) |
Classification of Corneal Shape Images by Machine Learning Yuji Ayatsuka (CRESCO), Kazutaka Kamiya (Kitasato Univ.), Yudai Kato, Yusuke Kudo (CRESCO), Fusako Fujimura, Nobuyuki Shoji (Kitasato Univ.), Yosai Mori, Kazunori Miyata (Miyata Eye Hospital) MI2018-22 |
Keratoconus is one of an ophthalmic disease on a cornea, which brings thinning and deformation in the center of cornea a... [more] |
MI2018-22 pp.5-8 |
PRMU, MI, IE, SIP |
2018-05-17 15:15 |
Gifu |
|
On OCT Volumetric Data Restoration via Hierarchical Sparsity and Hard Constraint Shogo Muramatsu, Satoshi Nagayama, Samuel Choi (Niigata Univ.), Shunsuke Ono (Tokyo Institute of Tech.), Takeru Ota, Fumiaki Nin, Hiroshi Hibino (Niigata Univ.) SIP2018-3 IE2018-3 PRMU2018-3 MI2018-3 |
This work proposes a novel restoration method for optical coherence tomography (OCT) data. OCT is a measurement techniqu... [more] |
SIP2018-3 IE2018-3 PRMU2018-3 MI2018-3 pp.7-12 |
SIP, EA, SP, MI (Joint) [detail] |
2018-03-19 11:00 |
Okinawa |
|
Research on Automatic Fundus Disease Diagnostic Support based on OCT Angiography Image Analysis Shinnosuke Yamaoka, Shinya Fukumoto, Masayuki Kashima, Kiminori Sato, Mutsumi Watanabe, Hideki Shiihara, Shozo Sonoda, Taiji Sakamoto (Kagoshima Univ.) MI2017-68 |
Optical coherence tomography (OCT) can shoot fundus photography used fundus examination. the purpose of this study is to... [more] |
MI2017-68 pp.19-24 |
US |
2017-10-05 13:25 |
Miyagi |
|
Improvement of High Frequency Ultrasound Images by Point Spread Function Obtained with Optical Coherence Tomography Naoshi Kashiwagura, Ryo Nagaoka (Tohoku Univ), Kazuto Kobayashi (HONDA ELECTRONICS), Yoshihumi Saijo (Tohoku Univ) US2017-57 |
A novel skin imaging combining ultrasound and optical coherence tomography (OCT) is proposed in the present study. Point... [more] |
US2017-57 pp.5-10 |
R, EMD, CPM, LQE, OPE |
2017-08-31 14:20 |
Aomori |
|
Suppression of SS-OCT thickness Measurement Value Drift by Adaptation to Central Wavelength Shift of Sweep Range Masahiro Ueno, Takashi Sakamoto, Seiji Toyoda, Yuzo Sasaki, Joji Yamaguchi, Tadashi Sakamoto (NTT), Masatoshi Fujimoto, Mahiro Yamada (Hamamatsu Photonics K. K.), Eiichi Sugai, Toru Kodaira (NTT-AT) R2017-26 EMD2017-20 CPM2017-41 OPE2017-50 LQE2017-23 |
Swept source optical coherence tomography (SS-OCT) is a technique to capture tomographic images of moving objects at hig... [more] |
R2017-26 EMD2017-20 CPM2017-41 OPE2017-50 LQE2017-23 pp.11-16 |
IT, SIP, RCS |
2017-01-19 16:10 |
Osaka |
Osaka City Univ. |
Source Estimation of en-face OCT by Sparse Signal Modeling Takumi Kawamura, Shunpei Ito, Shogo Muramatsu, Samuel Choi (Niigata Univ.) IT2016-79 SIP2016-117 RCS2016-269 |
This work proposes a perform source estimation method of en-face optical coherence tomography (OCT)
through sparse sign... [more] |
IT2016-79 SIP2016-117 RCS2016-269 pp.195-200 |
MI |
2016-11-14 10:00 |
Tottori |
Tottori Univ. |
Detecting Occular Diseases from an Optical Coherence Tomography Image by Machine Learning Yuji Ayatsuka (CRESCO), Soichiro Kuwayama, Hideaki Usui, Aki Kato, Yuichiro Ogura, Tsutomu Yasukawa (NCU) MI2016-64 |
We applied machine learning technique with Convolutional Neural Network
for Optical Coherence Tomography (OCT) images,... [more] |
MI2016-64 pp.11-14 |