IEICE Technical Committee Submission System
Conference Schedule
Online Proceedings
[Sign in]
Tech. Rep. Archives
    [Japanese] / [English] 
( Committee/Place/Topics  ) --Press->
 
( Paper Keywords:  /  Column:Title Auth. Affi. Abst. Keyword ) --Press->

All Technical Committee Conferences  (Searched in: All Years)

Search Results: Conference Papers
 Conference Papers (Available on Advance Programs)  (Sort by: Date Descending)
 Results 1 - 10 of 10  /   
Committee Date Time Place Paper Title / Authors Abstract Paper #
MBE, NC
(Joint)
2015-12-19
09:50
Aichi Nagoya Institute of Technology MR signal detection of hyperpolarized xenon with atomic magnetometers in ultra-low field based on SWIFT approach
Yuki Kaga, Takenori Oida, Tetsuya Yamamoto, Tetsuo Kobayashi (Kyoto Univ.) MBE2015-80
In recent years, ultra-low field MRI (ULF-MRI) has been attracting attention because of its advantages such as low maint... [more] MBE2015-80
pp.101-106
MBE, NC
(Joint)
2015-07-18
14:15
Tokushima The University of Tokushima Optimization of receiver system for ultra-low field MRI with optically pumped atomic magnetometer
Tetsuya Yamamoto, Takenori Oida, Tetsuo Kobayashi (Kyoto Univ.) MBE2015-21
Recently, ultra-low field (ULF) magnetic resonance imaging (MRI) has attracted attention. However, due to the low resona... [more] MBE2015-21
pp.7-12
MBE, NC
(Joint)
2014-10-18
15:50
Osaka Osaka Electro-Communication University Measurements of event-related desynchronizations and event-related fields with an atomic magnetometer module
Keigo Kamada, Yosuke Ito, Hiroaki Natsukawa (Kyoto Univ.), Kazuhisa Okano, Natsuhiko Mizutani (Canon), Tetsuo Kobayashi (Kyoto Univ.) MBE2014-57
In the field of biomagnetic measurements, various miniaturized optically pumped atomic magnetometers (OPAMs) have been d... [more] MBE2014-57
pp.31-36
NC, MBE
(Joint)
2014-03-18
09:40
Tokyo Tamagawa University A theoretical study on spatial homogeneity of spin polarization in an optically pumped K-Rb hybrid atomic magnetometer toward biomagnetic field measurements
Daichi Sato, Keigo Kamada, Yosuke Ito, Tetsuo Kobayashi (Kyoto Univ.) MBE2013-132
An optically pumped K-Rb hybrid atomic magnetometer is suitable in realizing simultaneous signal measurements at multipl... [more] MBE2013-132
pp.91-96
NC, MBE
(Joint)
2013-12-21
15:20
Gifu Gifu University Characteristics of a Compact Optically-Pumped Atomic-Magnetometer Module -- Effect of Inhomogeneity of Spin Polarization in the Alkali Metal Cell --
Natsuhiko Mizutani, Kazuhisa Okano, Kazuhiro Ban, Sunao Ichihara, Akira Terao (Canon), Tetsuo Kobayashi (Kyoto Univ.) MBE2013-87
The characteristics of a compact optically-pumped atomic-magnetometer (OPAM) module were not described well by an unifor... [more] MBE2013-87
pp.63-68
NC, MBE
(Joint)
2013-12-21
15:45
Gifu Gifu University Study on multiple flux transformers with saddle coils for ultra-low field MRI using an optically pumped atomic magnetometer
Masato Muto, Takenori Oida, Tetsuo Kobayashi (Kyoto Univ.) MBE2013-88
Recently, ultra-low field MRIs have attracted attention. The ULF-MRI requires a high-sensitive sensor in low-frequency ... [more] MBE2013-88
pp.69-74
MBE, NC
(Joint)
2013-03-13
14:10
Tokyo Tamagawa University Magnetic field distribution measurements with an optically pumped atomic magnetometer using a hybrid cell of K and Rb atoms for biomagnetic measurements
Yosuke Ito, Daichi Sato, Hiroyuki Ohnishi, Keigo Kamada, Tetsuo Kobayashi (Kyoto Univ.) MBE2012-93
We have been developing an ultra-high sensitivity optically pumped atomic magnetometer using a hybrid cell of K and Rb a... [more] MBE2012-93
pp.31-34
MBE 2011-07-09
10:50
Tokushima The University of Tokushima Human MCG measurements with an ultrasensitive optically-pumped atomic magnetometer
Keigo Kamada, Yosuke Ito, Tetsuo Kobayashi (Kyoto Univ.) MBE2011-33
Measurement of biomagnetic fields such as magnetoencephalograms (MEGs) and magnetocardiograms (MCGs) is one of the impor... [more] MBE2011-33
pp.71-76
MBE 2010-05-21
13:50
Toyama Toyama Univ. Development of an ultrasensitive optically-pumped atomic magnetometer for biomagnetic measurements -- Studies on dependence of sensitivity and bandwidth on operating conditions --
Keigo Kamada, Shuji Taue (Kyoto Univ.), Kiyoshi Ishikawa (Univ. of Hyogo), Tetsuo Kobayashi (Kyoto Univ.) MBE2010-3
We have developed an ultrasensitive optically-pumped atomic magnetometer for biomagnetic measurements such as magnetoenc... [more] MBE2010-3
pp.13-18
MBE 2009-07-11
10:55
Tokushima The University of Tokushima Development of an ultrasensitive optically-pumped atomic magnetometer for biomagnetic measurements -- Measurements and simulations of magnetic field distributions from a spherical phantom considering distributed currents --
Yasuyuki Sugihara, Shuji Taue (Kyoto Univ.), Sunao Ichihara (Canon), Kiyoshi Ishikawa (Kyoto Univ./Univ. of Hyogo), Tetsuo Kobayashi (Kyoto Univ.) MBE2009-26
We have developed an ultrasensitive optically-pumped atomic magnetometer for biomagnetic measurements such as magnetoenc... [more] MBE2009-26
pp.39-44
 Results 1 - 10 of 10  /   
Choose a download format for default settings. [NEW !!]
Text format pLaTeX format CSV format BibTeX format
Copyright and reproduction : All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034)


[Return to Top Page]

[Return to IEICE Web Page]


The Institute of Electronics, Information and Communication Engineers (IEICE), Japan