Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
EMCJ |
2022-07-14 15:30 |
Tokyo |
(Primary: On-site, Secondary: Online) |
Method for estimating coupling to nearby a communication cable using common mode voltage/current distribution of the EV harness Makoto Fujimura, Kyousuke Tanaka, Tohlu Matsushima, Yuki Fukumoto (KIT) |
(To be available after the conference date) [more] |
|
EMCJ |
2022-07-14 15:55 |
Tokyo |
(Primary: On-site, Secondary: Online) |
Dependence of radiated electromagnetic disturbance on exposure range of single-wire harness Koki Iwasa, Tohlu Matsushima, Yuki Fukumoto (Kyutech) |
(To be available after the conference date) [more] |
|
EMCJ |
2022-06-10 09:30 |
Hokkaido |
Hokkaido University (Primary: On-site, Secondary: Online) |
Common-mode voltage reduction by controlling parasitic impedance around three-phase inverter circuit with consideration of load circuit Taiki Kai, Tohlu Matsushima, Yuki Fukumoto, Kohei Takada, Koji Kobayashi (SANDEN) EMCJ2022-15 |
In recent years, as switching devices have increased in switching speed, electromagnetic disturbances generated from pow... [more] |
EMCJ2022-15 pp.5-10 |
EMCJ |
2022-06-10 10:35 |
Hokkaido |
Hokkaido University (Primary: On-site, Secondary: Online) |
Evaluation of Immunity Characteristics of Harnesses Connecting In-vehicle Communication Devices by Applying Radiated Disturbances Akito Kagawa, Tohlu Matsushima, Yukihiro Fukumoto (Kyutech) EMCJ2022-17 |
[more] |
EMCJ2022-17 pp.15-20 |
EMCJ |
2022-05-20 15:50 |
Kyoto |
Campus Plaza Kyoto (Primary: On-site, Secondary: Online) |
[Invited Talk]
Trends in In-vehicle Network EMC Standards and Related Evaluation Methods Osami Wada (Kyoto Univ,), Jianqing Wang, Yusuke Yano (Nagoya Inst. Tech.), Tohlu Matsushima (Kyushu Inst. Tech.), Takeshi Ishida (NoiseKen) EMCJ2022-13 |
With the progress of ADAS for electrification of automobiles and autonomous driving, reliability requirements for in-veh... [more] |
EMCJ2022-13 pp.27-32 |
EMCJ |
2022-04-15 15:35 |
Okinawa |
(Primary: On-site, Secondary: Online) |
Signal application method using a power divider for mode-multiplex transmission over shielded quad pair cable Tohlu Matsushima, Iori Imagawa, Yuki Fukumoto (Kyutech) EMCJ2022-7 |
[more] |
EMCJ2022-7 pp.37-42 |
UWT (2nd) |
2022-03-01 13:30 |
Online |
Online |
Long-Distance Radio Communication Underwater/Undersea
-- Wide-band Antenna and Application of PaWalet Link Under Seawater -- Miyuki Hirose, Tohlu Matsushima, Yuki Fukumoto (KIT), Kazuhiro Eguchi, Hisao Koga, Toshiyuki Wakisaka (Panasonic) |
Our project aimed at establishing technologies for developing wireless communication under water and seawater. Some rese... [more] |
|
EMCJ |
2022-01-21 10:05 |
Online |
Online |
Detection of fault locations in an unbranched power distribution line using deep learning algorithm Daiki Nagata, Tohlu Matsushima, Yuki Fukumoto, Hideaki Kawano, Shunya Fujioka (Kyushu Inst of Tech) EMCJ2021-61 |
In fault detection in overhead power distribution systems, it is desired to take immediate response with fewer people. T... [more] |
EMCJ2021-61 pp.1-6 |
EMCJ |
2022-01-21 15:45 |
Online |
Online |
Simple Method of Determining Chain-Parameter-Matrix Elements for Multi-Conductor Shielded Cable Nobuo Kuwabara, Tohlu Matsushima, Yuki Fukumoto (KIT) EMCJ2021-71 |
Multiconductor shielded cables are used in vehicles and electronic devices to maintain EMC quality. A method using a cha... [more] |
EMCJ2021-71 pp.57-62 |
EMCJ, IEE-EMC, IEE-SPC |
2021-12-08 15:45 |
Aichi |
(Primary: On-site, Secondary: Online) |
Reduction of Common-mode Voltage in Three-phase Inverter by Impedance balancing method Taiki Kai, Tohlu Matsushima, Yuki Hukumoto (Kyushu Institute of Technology), Koji Kobayashi, Kohei Takada (Sanden AT) EMCJ2021-60 |
[more] |
EMCJ2021-60 pp.34-39 |
EMCJ, EMD, WPT (Joint) |
2021-07-02 13:30 |
Online |
Online |
Three-dimensional Communication Range Design for Transceiver Coils in HF Broadband Communication Kensi Kuwahara, Toshiyuki Wakisaka, Tohlu Matsushima, Yuki Fukumoto (kyutech) EMCJ2021-26 |
With the spread of IoT systems in recent years, selecting the appropriate communication system for the application will ... [more] |
EMCJ2021-26 pp.7-12 |
EMCJ |
2021-06-11 14:00 |
Online |
Online |
Electromagnetic field analysis of common mode excitation measurement system in signal connector with incomplete ground connection Shotaro Tanaka, Tohlu Matsushima, Yuki Fukumoto (kyutech) EMCJ2021-12 |
Electromagnetic interference (EMI) due to common mode current generated from high-speed digital circuits on printed circ... [more] |
EMCJ2021-12 pp.7-12 |
EMCJ, MICT (Joint) |
2021-03-05 09:25 |
Online |
Online |
Experimental study of signal application method using add circuit in mode-division multiplexed transmission method Takuya Sato, Tohlu Matsushima, Yuki Fukumoto (Kyutech) EMCJ2020-73 |
In high-speed wired communications, studies are being conducted to increase the transmission capacityby using multiple l... [more] |
EMCJ2020-73 pp.7-12 |
EMCJ, MICT (Joint) |
2021-03-05 16:15 |
Online |
Online |
Simulation of TDR waveform for fault location in overhead distribution line Fumikazu Kobayashi, Tohlu Matsushima, Yuki Fukumoto (Kyutech), Takashi Hisakado (Kyoto Univ.), Yusuke Kokubo, Shoichi Higashiyama, Yuko Inaoka (Kansai Transmission and Distribution, Inc.), Yusuke Sasaki (DAIHEN Corporation) EMCJ2020-82 |
It has been investigated that time domain reflectometry method was applied to an overhead distribution line to locate a ... [more] |
EMCJ2020-82 pp.51-56 |
EMCJ, MICT (Joint) |
2021-03-05 16:35 |
Online |
Online |
A Study on variation of Frame Error Rate using simulation for immunity evaluation of Ethernet immunity to Pulsed Interference. Kenta Ishibashi, Tohlu Matsushima, Yuki Fukumoto (Kyutech) EMCJ2020-83 |
In recent years, with development of automated driving technology, it is necessary to increase capacity of in-vehicle co... [more] |
EMCJ2020-83 pp.57-62 |
EMCJ |
2021-01-22 13:40 |
Online |
Online |
TLP circuit for immunity evaluation emulating electromagnetic disturbance in automobile Kyousuke Tanaka, Dai-ichiro Koike, Tohlu Matsushima, Yuki Fukumoto (Kyutech) EMCJ2020-65 |
The purpose of this research is to make a disturbance generator for evaluation of immunity characteristic of electronic ... [more] |
EMCJ2020-65 pp.7-12 |
EMCJ |
2020-09-28 13:35 |
Online |
Online |
Evaluation of transmission characteristics and crosstalk of mode-division multiplexed transmission on parallel 4-wire microstrip lines Iori Imagawa, Takuya Sato, Tohlu Matsushima, Yuki Fukumoto (KIT) EMCJ2020-21 |
[more] |
EMCJ2020-21 pp.1-6 |
EMCJ |
2020-07-02 13:50 |
Online |
Online |
A simplified simulation method of common-mode current considering imbalances of signal sources Takato Yonemura (Kyutech), Koichi Kikuchi (TDK), Tohlu Matsushima, Yuki Fukumoto (Kyutech) EMCJ2020-12 |
It is challenging to simulate electromagnetic phenomena, such as common-mode current for in-vehicle equipment that compl... [more] |
EMCJ2020-12 pp.7-12 |
EMCJ |
2020-04-17 14:25 |
Ishikawa |
Kanazawa Univ. Satellite 3F (Cancelled but technical report was issued) |
Measurement and analysis of radiated magnetic field using scale model of power line communication network Dai-ichiro Koike, Daiki Matsuo, Tohlu Matsushima, Yuki Fukumoto (KIT) EMCJ2020-3 |
[more] |
EMCJ2020-3 pp.11-16 |
EMCJ, IEE-EMC |
2020-01-24 10:55 |
Ehime |
|
Evaluation method of common-mode conversion in communication device connected with STP cable Fumikazu Kobayashi, Tohlu Matsushima, Yuki Fukumoto (Kyutech) EMCJ2019-83 |
A mixed-mode S-parameter and a longitudinal conversion loss have been proposed for evaluation of mode conversion between... [more] |
EMCJ2019-83 pp.11-16 |