IEICE Technical Committee Submission System
Conference Schedule
Online Proceedings
[Sign in]
Tech. Rep. Archives
    [Japanese] / [English] 
( Committee/Place/Topics  ) --Press->
 
( Paper Keywords:  /  Column:Title Auth. Affi. Abst. Keyword ) --Press->

All Technical Committee Conferences  (All Years)

Search Results: Conference Papers
 Conference Papers (Available on Advance Programs)  (Sort by: Date Descending)
 Results 1 - 20 of 23  /  [Next]  
Committee Date Time Place Paper Title / Authors Abstract Paper #
US 2021-06-18
16:25
Online Online Basic study of discrimination evaluation of fibers and fats in organs by amplitude enveloping characteristic analysis
Yuki Ujihara (Chiba Univ.), Kazuki Tamura (Hamamatsu Med. Univ.), Shohei Mori (Tohoku Univ.), Po-Hsiang Tsui (Chang Gung Univ.), Shinnosuke Hirata, Kenji Yoshida, Tadashi Yamaguchi (Chiba Univ.) US2021-15
In recent years, the quantitative evaluation of liver diseases such as NASH, in which fibrous tissue and fat droplets ar... [more] US2021-15
pp.41-44
US 2020-08-26
14:55
Online Online Analysis of fluctuations of sound reflected on sea surface using the FDTD method
Tomoya Tsukui (Tokyo Tech), Shinnosuke Hirata (Chiba Univ), Hiroyuki Hachiya (Tokyo Tech) US2020-24
Many kinds of hydro acoustic devices are used in the field of ocean development of resources and observations. These dev... [more] US2020-24
pp.21-26
US 2020-08-26
15:20
Online Online Accuracy evaluation of liver fibrosis estimation based on multi-Rayleigh model with two components considering the effect of lateral resolution
Chuang Zhang, Shinnosuke Hirata, Hiroyuki Hachiya (Tokyo Tech.) US2020-25
We have been developing a quantitative estimation method of liver fibrosis using multi-Rayleigh model to express a proba... [more] US2020-25
pp.27-32
US 2019-06-17
16:00
Tokyo Akihabara satellite campus, Tokyo Metropolitan University Evaluation of liver fibrosis with high estimation accuracy by using moments of the probability density function of echo envelope in complex space
Chuang Zhang, Shinnosuke Hirata, Hiroyuki Hachiya (Tokyo Tech.) US2019-24
We have been developing a quantitative estimation method of liver fibrosis using multi-Rayleigh model to express a proba... [more] US2019-24
pp.25-30
EA, US
(Joint)
2019-01-22
14:00
Kyoto Doshisha Univ. [Poster Presentation] Basic study of measurement method of broadband ultrasonic attenuation in non-contact QUS
Toshiaki Okubo, Shinnosuke Hirata, Hiroyuki Hachiya (TokyoTech) US2018-100
QUS is widely used as screenings of osteoporosis. In this study, a method of measurement of speed of sound (SOS) and bro... [more] US2018-100
pp.103-106
US 2018-08-30
13:30
Tokyo Tokyo Institute of Technology Quantitative analysis of acoustic reflection characteristics on sea surface using FDTD simulation
Tomoya Tsukui, Shinichi Sawada (IHI), Shinnosuke Hirata, Hiroyuki Hachiya (Tokyo Tech) US2018-41
Many kinds of hydro acoustic devices are used in the field of ocean development of resources and observations with AUV a... [more] US2018-41
pp.1-6
US 2018-05-21
16:20
Tokyo   Consideration about evaluation method of road surface roughness by amplitude statistics of sound waves reflected from the road surface
Naoki Shinoda, Shinnosuke Hirata, Hiroyuki Hachiya (Tokyo Tech) US2018-17
Spatial information measurement such as road surface measurement and road obstacle detection is useful for automatic ope... [more] US2018-17
pp.35-40
US 2017-08-31
10:00
Kanagawa   Variability characteristics of sound reflection on sea surface with wave -- A result of water tank experiment --
Tomoya Tsukui, Shinichi Sawada (IHI), Shinnosuke Hirata, Hiroyuki Hachiya (Tokyo Inst. of Tech.) US2017-46
Various hydro acoustic devices are used in the field of ocean development of resources and observations with AUV and ASV... [more] US2017-46
pp.1-6
US 2017-05-22
13:55
Tokyo   Non-contact measurement of body-surface displacement by breathing and heart beat using airborne acoustic images
Taiki Hayashi, Shinnosuke Hirata, Hiroyuki Hachiya (Tokyo Inst. of Tech.) US2017-15
Today, vital signs measurement systems, in which sensors are had contact with or closed to body surface, are widely prev... [more] US2017-15
pp.7-12
EA, US
(Joint)
2017-01-25
10:30
Kyoto Doshisha Univ. [Poster Presentation] Relationship of shear wave velocity and excited vibration waveform in tissue mimicking phantom
Hiroto Hasegawa, Shihei Mori, Shinnosuke Hirata, Hiroyuki Hachiya (Tokyo Tech) US2016-83
It is known shear modulus of fibrotic liver tissues becomes larger than that of normal tissues. Many approaches to evalu... [more] US2016-83
pp.55-60
EA, US
(Joint)
2017-01-26
11:20
Kyoto Doshisha Univ. Airborne ultrasonic position and velocity measurement by using two types of LPM signals and multiple moving objects tracking
Haruki Chiba, Ko Sakai, Shinnosuke Hirata (Tokyo Tech), Yuichiro Orino (The University of Shiga Prefecture), Minoru K Kurosawa (Tokyo Tech) US2016-112 EA2016-80
Ultrasonic distance measurement with pulse-echo is based on determination of the time of flight of ultrasonic pulses. In... [more] US2016-112 EA2016-80
pp.197-202(US), pp.73-78(EA)
US 2016-08-25
14:25
Tokyo Tokyo Institute of Technology, Ookayama Campus Evaluation of sound reflection characteristics on sea surface with ocean waves using the FDTD method.
Tomoya Tsukui, Shinichi Sawada (IHI), Shinnosuke Hirata, Hiroyuki Hachiya (Tokyo Tech) US2016-39
(To be available after the conference date) [more] US2016-39
pp.7-12
US, EA
(Joint)
2016-01-29
15:30
Osaka Kansai University, Centenary Memorial Hall Experimental evaluation of imaging method of liver tissues for quantitative diagnosis using a contrast phantom with three areas
Minori Ohashi, Shinnosuke Hirata, Hiroyuki Hachiya (Tokyo Tech) US2015-104
 [more] US2015-104
pp.117-122
US 2015-10-09
14:00
Ishikawa Kanazawa Institute of Technology Study about multi-channelization in ultrasonic distance measurement using LFM signal coded by M-sequence
Kota Yamanaka, Shinnosuke Hirata, Hiroyuki Hachiya (Tokyo Tech) US2015-60
In ultrasonic distance measurement by the pulse-echo method, the signal-to-noise ratio (S/N) of the received echo and th... [more] US2015-60
pp.13-18
US 2015-06-19
12:55
Kumamoto Kumamoto University Estimation accuracy of quantitative diagnostic method for liver fibrosis considering nonspeckle signals in ultrasound B-mode image of clinical data
Shohei Mori, Shinnosuke Hirata (Tokyo Tech), Tadashi Yamaguchi (Chiba Univ.), Hiroyuki Hachiya (Tokyo Tech) US2015-17
A quantitative diagnostic method for liver fibrosis using a multi-Rayleigh model which is a model of a probability densi... [more] US2015-17
pp.7-12
US, EA
(Joint)
2015-01-28
16:15
Kyoto Doshisha Univ. Detection of pass-through airborne ultrasound for non-contact measurement of acoustic characteristics in tissues
Koichi Terashima, Shinnosuke Hirata, Hiroyuki Hachiya (Tokyo Tech), Nobuo Niimi (NIPPON SIGMAX) US2014-81 EA2014-60
Ultrasonic bone assessment based on the propagation speed or attenuation characteristic of ultrasound in cancellous bone... [more] US2014-81 EA2014-60
pp.39-43(US), pp.7-11(EA)
US 2014-11-13
15:20
Ishikawa Kanazawa Institute of Technology Improvement of Doppler velocity estimation by spectrum pattern analysis of M-sequence-modulated ultrasound in noisy environments
Yohei Ikari, Shinnosuke Hirata, Hiroyuki Hachiya (Tokyo Tech) US2014-62
 [more] US2014-62
pp.23-28
US 2014-06-23
14:40
Tokyo Tokyo Metropolitan Univ. Approach for quantitative liver tissue characterization based on texture analysis considering slice resolution of ultrasonic image
Hiroshi Isono, Shinnosuke Hirata, Hiroyuki Hachiya (Tokyo Inst. of Tech.) US2014-20
As the method for quantitative liver tissue characterization, we have been focusing on texture analysis by using co-occu... [more] US2014-20
pp.19-24
EA, US
(Joint)
2014-01-27
13:00
Osaka Kansai University, Centenary Memorial Hall Position and velocity imaging of moving objects using the M-sequence modulated ultrasound
Yohei Ikari, Shinnosuke Hirata, Hiroyuki Hachiya (Tokyo Inst. of Tech.) US2013-86
Pulse compression using M-sequence modulated signals can improve the SNR of the reflected echo and distance resolution i... [more] US2013-86
pp.25-30
US 2013-11-11
17:15
Ishikawa Kanazawa Inst. Tech. Simulation for the effect of the beam width on quantitative estimation of liver fibrosis using ultrasonic images
Shohei Mori, Shinnosuke Hirata, Hiroyuki Hachiya (Tokyo Inst. of Tech.) US2013-61
In order to realize quantitative diagnosis of liver fibrosis, we have been developing a method of quantitative evaluatio... [more] US2013-61
pp.43-48
 Results 1 - 20 of 23  /  [Next]  
Choose a download format for default settings. [NEW !!]
Text format pLaTeX format CSV format BibTeX format
Copyright and reproduction : All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034)


[Return to Top Page]

[Return to IEICE Web Page]


The Institute of Electronics, Information and Communication Engineers (IEICE), Japan