|
|
All Technical Committee Conferences (Searched in: All Years)
|
|
Search Results: Conference Papers |
Conference Papers (Available on Advance Programs) (Sort by: Date Descending) |
|
Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
MBE |
2012-01-27 16:20 |
Fukuoka |
Kyushu University |
Effect of pre-filter application for detection of Legionella pneumophila using gene identification method with the metal coated flat sheet membrane Tomohiro Kitajima, Toshitsugu Sugawara, Junji Arisawa, Kazuyuki Kimura (HIT), Osamu Igarashi (NIX,INC,) MBE2011-90 |
Plate culture increased a patient of Legionnaires' disease because it needed to detect Legionella species in hot spring ... [more] |
MBE2011-90 pp.59-64 |
MBE |
2012-01-27 16:45 |
Fukuoka |
Kyushu University |
Study on improvement effect of RNA virus detection using the metal-coated hollow fiber membrane with reverse transcription loop-mediated isothermal amplification from a human plasma sample Taichi Endo, Toshitsugu Sugawara, Junji Arisawa, Kazuyuki Kimura (HIT), Osamu Igarashi (NIX) MBE2011-91 |
We proposed the virus detection with gene amplification method which was also detectable from very small quantity of a v... [more] |
MBE2011-91 pp.65-70 |
MBE |
2011-01-28 11:25 |
Kagoshima |
Kagoshima University |
RNA virus ditection used Metal coated hollow fiber membrane and Reverse Transcription Loop-mediated Isothermal Amplification from simulated serum sample Shinya Hayashi, Toshitsugu Sugawara, Junji Arisawa, Kazuyuki Kimura (HIT), Osamu Igarashi (NIX) MBE2010-93 |
Japanese Red Cross Society has carried out Nucleic acid Amplification Test (NAT) to secure safety of a blood supply. How... [more] |
MBE2010-93 pp.77-82 |
MBE |
2009-01-24 11:25 |
Saga |
Saga University |
Study on sensitivity of detection used Metal-coated hollow fiber membrane and Reverse Transcription Loop-mediated Isothermal Amplification for RNA virus Hayato Baba, Toshitsugu Sugawara, Kazuyuki Kimura, Kenji Misawa, Junji Arisawa (Hokkaido Inst. of Tech.), Osamu Igarashi (NIX Inc.) MBE2008-87 |
Japanese Red Cross Society has been employing Nucleic acid Amplification Test (NAT) to secure safety of a blood supply. ... [more] |
MBE2008-87 pp.55-59 |
MBE |
2007-01-26 10:00 |
Kagoshima |
Kagoshima-Shichoson-Jichi-Kaikan Bldg. |
Isolation and Identification of Legionella pneumophila from hot spring water using a metal-coated flat sheet membrane with genetic engineering technique. Hiroyuki Shimabe, Toshitsugu Sugawara, Kazuyuki Kimura, Kenji Misawa, Junji Arisawa (HIT), Osamu Igarashi (NIX) |
Generally, identification of Legionella spp. spends more than a week. A method for rapid detection is therefore required... [more] |
MBE2006-99 pp.13-16 |
MBE |
2007-01-26 10:20 |
Kagoshima |
Kagoshima-Shichoson-Jichi-Kaikan Bldg. |
Influence of the Difference Between Serum Specimen on the Viral Detection Method using Gene Engineering Technique and Preparation for Development its RNA Virus Detection Akira Ohnishi, Toshitsugu Sugawara, Kazuyuki Kimura, Kenji Misawa, Junji Arisawa (HIT), Osamu Igarashi (NIX) |
The Japanese Red Cross Society is using nucleic acid amplification testing (NAT) to secure the microbiological safety of... [more] |
MBE2006-100 pp.17-20 |
MBE |
2004-11-15 16:45 |
Miyagi |
Tohoku Univ. |
Influence of serum on the virus detection using the metal-coated hollow fiber membrane Makoto Ebikawa, Toshitsugu Sugawara, Kazuyuki Kimura, Kenji Misawa, Junji Arisawa, Osamu Igarashi (HIT) |
[more] |
MBE2004-65 pp.53-56 |
|
|
|
Copyright and reproduction :
All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034)
|
[Return to Top Page]
[Return to IEICE Web Page]
|