IEICE Technical Committee Submission System
Conference Schedule
Online Proceedings
[Sign in]
... (for ESS/CS/ES/ISS)
Tech. Rep. Archives
... (for ES/CS)
    [Japanese] / [English] 
( Committee/Place/Topics  ) --Press->
 
( Paper Keywords:  /  Column:Title Auth. Affi. Abst. Keyword ) --Press->

All Technical Committee Conferences  (All Years)

Search Results: Conference Papers
 Conference Papers (Available on Advance Programs)  (Sort by: Date Descending)
 27件中 1~20件目  /  [Next]  
Committee Date Time Place Paper Title / Authors Abstract Paper #
MI 2019-01-23
16:20
Okinawa   (To be available after the conference date) [more] MI2018-115
pp.239-240
MICT, MI 2018-11-06
15:50
Hyogo University of Hyogo (To be available after the conference date) [more] MICT2018-51 MI2018-51
pp.59-60
SIP, EA, SP, MI
(Joint) [detail]
2018-03-20
13:30
Okinawa   (To be available after the conference date) [more] MI2017-93
pp.101-102
SIP, EA, SP, MI
(Joint) [detail]
2018-03-20
13:30
Okinawa   (To be available after the conference date) [more] MI2017-96
pp.109-110
MI 2017-09-25
10:00
Chiba Chiba Univ. (To be available after the conference date) [more] MI2017-37
pp.1-2
EA, US
(Joint)
2017-01-25
10:30
Kyoto Doshisha Univ. Evaluation of relationship between tissue viscoelasticity and acoustic characteristics using lesion model rat liver
Kenoh Murakami, Deng Zhihao, Kazuyo Ito (Chiba Univ.), Kenji Yoshida, Mikio Suga (Chiba Univ. CFME), Takayuki Obata, Riwa Kishimoto (NIRS), Hitoshi Maruyama (Chiba Univ.), Tadashi Yamaguchi (Chiba Univ. CFME)
 [more] US2016-85
pp.67-72
MI 2017-01-18
14:15
Okinawa Tenbusu Naha (To be available after the conference date) [more] MI2016-85
pp.59-60
MI 2016-01-19
13:20
Okinawa Bunka Tenbusu Kan An automatic segmentation of the pelvic MRI for the PET attenuation correction
Hiroshi Kawaguchi (AIST), Takayuki Obata, Hiromi Sano, Eiji Yoshida (NIRS), Mikio Suga (Chiba Univ.), Yoko Ikoma (NIRS), Yukari Tanikawa (AIST), Taiga Yamaya (NIRS)
The automatic segmentation method of the MR image is mandatory to construct attenuation correction data for the clinical... [more] MI2015-82
pp.51-54
MI 2016-01-19
13:20
Okinawa Bunka Tenbusu Kan Feasibility study of a Compton-PET imaging system using multilayered detectors
Kohei Shinohara, Mikio Suga (Chiba Univ.), Eiji Yoshida, Hideaki Tashima, Jiang Jianyong, Ahmed Abdella Mohammednur, Taiga Yamaya (NIRS)
PET is a high sensitive imaging system that detects pairs of gamma rays emitted from positron emitters. Compton imaging ... [more] MI2015-83
pp.55-58
MI 2015-11-11
09:55
Nara NAIST Evaluation of MR Elastography system with two concave drivers for high viscosity tissue
Shimpei Shimazaki, Mikio Suga, Takaya Mori, Masashi Sekine (Chiba Univ.), Riwa Kishimoto, Takayuki Obata (NIRS)
Magnetic resonance elastography (MRE) is a method to visualize viscoelastic modulus from shear wave images in tissue. In... [more] MI2015-58
pp.5-8
MI 2015-03-03
13:40
Okinawa Hotel Miyahira Generation of attenuation correction factor for PET from a T1-weighted pelvic MR image using hybrid-segmentation and atlas method
Hiroshi Kawaguchi, Takayuki Obata, Hiromi Sano, Eiji Yoshida (NIRS), Mikio Suga (Chiba Univ.), Yoko Ikoma, Taiga Yamaya (NIRS)
The current attenuation correction method for human pelvic PET/MRI contains several problems such that the attenuation d... [more] MI2014-99
pp.221-226
MI 2013-09-13
14:15
Chiba   [Special Talk] Highly Accurate and Less-Invasive Diagnosis and Treatment for Diseases in Thoracoabdominal Organs
Hideaki Haneishi, Tadashi Yamaguchi, Ryoichi Nakamura, Mikio Suga, Toshiya Nakaguchi, Hiroshi Kawahira, Takashi Ohnishi (Chiba Univ.)
In hepato-biliary-pancreatic region, it is required to find a solid cancer formed in those organs and treat it less-inva... [more] MI2013-43
pp.31-34
MI 2013-01-24
13:10
Okinawa Bunka Tenbusu Kan Comparison of MR Elastography and US Elastography: a Phantom Study
Atsuhisa Koyama (Chiba Univ.), Mikio Suga (Chiba Univ./NIRS), Riwa Kishimoto (NIRS), Hajime Ikeda, Shinpei Shimazaki (Chiba Univ.), Tetsuya Wakayama (GEHC-J), Takayuki Obata, Hiroshi Tsuji (NIRS)
MR Elastography (MRE) and Ultrasound Elastography (USE) are used to quantify the storage modulus or shear wave velocity ... [more] MI2012-68
pp.33-36
MI 2013-01-25
13:10
Okinawa Bunka Tenbusu Kan in-vivo Brain MR Elastography using Mechanical Vibration of the Patient Table by Vibration Induced Switching Gradient
Hajime Ikeda (Chiba Univ.), Mikio Suga (Chiba Univ./NIRS), Atsuhisa Koyama, Shinpei Shimazaki (Chiba Univ.), Tetsuya Wakayama (GEHC-J), Riwa Kishimoto, Takayuki Obata (NIRS)
Magnetic resonance elastography (MRE) is a noninvasive method for measuring tissue quantitative elasticity. Current brai... [more] MI2012-107
pp.235-238
MI 2013-01-25
13:10
Okinawa Bunka Tenbusu Kan Influence of MRI-based attenuation correction methods on quantitative analysis of brain PET
Hiroshi Kawaguchi (NIRS), Asuka Tanigawa, Mikio Suga (Chiba Univ.), Yoshiyuki Hirano, Takahiro Shiraishi, Eiji Yoshida, Yasuyuki Kimura, Katsuyuki Tanimoto, Takayuki Obata, Hiroshi Ito, Taiga Yamaya (NIRS)
The quantitative capability is fundamental for PET in the human brain. Several attenuation correction methods for PET/MR... [more] MI2012-108
pp.239-244
MI 2012-01-20
15:50
Okinawa   The 2nd generation OpenPET geometry for joint cancer therapy imaging
Shoko Kinouchi (Chiba Univ./NIRS), Taiga Yamaya, Hideaki Tashima, Yoshiyuki Hirano, Eiji Yoshida, Fumihiko Nishikido (NIRS), Hideaki Haneishi, Mikio Suga (Chiba Univ.)
One of the challenging applications of positron emission tomography (PET) is in situ monitoring of the irradiation field... [more] MI2011-156
pp.437-439
MI 2011-09-06
10:20
Ibaraki AIST Development of Actuator for MR Elastography toward High-Resolution Viscoelasticity Measurement
Shinya Ozawa (Chiba Univ.), Mikio Suga (Chiba Univ./NIRS), Hajime Ikeda, Atsuhisa Koyama (Chiba Univ.), Tetsuya Wakayama (GEHCJ), Takayuki Obata (NIRS)
Magnetic Resonance Elastography (MRE) is a method to visualize local viscoelastic modulus from wave motion images in tis... [more] MI2011-50
pp.17-20
MI 2011-01-20
10:15
Okinawa Naha-Bunka-Tembusu Preliminary study of in-vivo liver measurement by optimized pulse sequence for MR elastography
Ken Arai (Chiba Univ.), Mikio Suga (Chiba Univ./NIRS), Shinya Ozawa, Hajime Ikeda (Chiba Univ.), Masaya Hirano (GEHC-JP), Etsuko Kobayashi (Tokyo Univ.), Takayuki Obata (NIRS)
Magnetic resonance elastography (MRE) is a technique for quantitative and noninvasive assessment of tissue elasticity. M... [more] MI2010-89
pp.47-50
MI 2010-01-28
09:55
Okinawa Naha-Bunka-Tenbusu Determination of starting time for graphical analysis using X-square test in PET receptor imaging
Hiroto Ogaki (Chiba Univ/NIRS), Kazuya Sakaguchi (NIRS), Mikio Suga (Chiba Univ/NIRS), Yuichi Kimura (NIRS/Chiba Univ)
This study aims at developing an algorithm to estimate a starting point, t*, for Logan Graphical Analysis (LGA) and Mult... [more] MI2009-75
pp.1-6
MI 2010-01-28
11:40
Okinawa Naha-Bunka-Tenbusu [Poster Presentation] Study of Implementation of Maximum-likelihood Reconstruction for Compton Camera
Yukio Okabe (Chiba Univ.), Taiga Yamaya, Eiji Yoshida, Fumihiko Nishikido (National Inst. of Radiological Sci.), Naoki Kawachi (JAEA), Mikio Suga (Chiba Univ.)
In this paper we compared two implementations, histogram mode(hist-mode) and list-mode,of -MLEM(maximum likelihood expec... [more] MI2009-83
pp.47-51
 27件中 1~20件目  /  [Next]  
Choose a download format for default settings. [NEW !!]
Text format pLaTeX format CSV format BibTeX format


[Return to Top Page]

[Return to IEICE Web Page]


The Institute of Electronics, Information and Communication Engineers (IEICE), Japan