IEICE Technical Committee Submission System
Conference Schedule
Online Proceedings
[Sign in]
Tech. Rep. Archives
    [Japanese] / [English] 
( Committee/Place/Topics  ) --Press->
 
( Paper Keywords:  /  Column:Title Auth. Affi. Abst. Keyword ) --Press->

All Technical Committee Conferences  (Searched in: All Years)

Search Results: Conference Papers
 Conference Papers (Available on Advance Programs)  (Sort by: Date Descending)
 Results 1 - 17 of 17  /   
Committee Date Time Place Paper Title / Authors Abstract Paper #
MBE, NC
(Joint)
2017-03-13
10:50
Tokyo Kikai-Shinko-Kaikan Bldg. An Impact Force Analysis of the Simple Hammering Mechanism for Concrete Damage Detection
Yuki Yoshida (KIT), Okumura Katsuhiro, Koga Fumitaka, Yamada Keiichi, Tanaka Masatoshi (FITC), Hideki Wada (SHK-K), Hiroaki Wagatsuma (KIT/RIKEN/AIST BSI/AIRC, AIST) NC2016-80
In order to build an automated system for anomaly detection such as concrete cracks through hammering tests, hammering m... [more] NC2016-80
pp.97-102
EMCJ, WPT
(Joint)
2014-01-31
16:35
Saga Saga Univ. A Study on Equivalent Radiation Source Modeling of Electronic Equipment for Far Field Estimation
Masato Kawabata, Yasuhiro Ishida (Fukuoka Industrial Technology Center), Nobuo Kuwabara (Kyushu Inst. of Tech.) EMCJ2013-131
It is difficult to estimate radiated emissions from an electronic equipment in offices or vehicles. We have studied the ... [more] EMCJ2013-131
pp.117-122
EMCJ 2012-01-27
09:45
Fukuoka Kyushu Univ. Estimation of E-field Emitted from In-vehicle Equipment Using Radiation Source Modeling Method and FDTD Method
Masato Kawabata, Yasuhiro Ishida (Fukuoka Industrial Technology Center), Nobuo Kuwabara (KIT) EMCJ2011-113
It is difficult to estimate radiated emissions from an electric equipment in offices or vehicles. We have studied the es... [more] EMCJ2011-113
pp.13-18
EMCJ 2011-01-28
14:35
Kumamoto Kumamoto National College of Technology Application of Pyramidal Foam Absorber for Compact Anechoic Chamber above 1 GHz -- Relation between Site VSWR and Time Domain Evaluation --
Masato Kawabata (Fukuoka Industrial Technology Center), Hiroshi Onomae (Kagoshima Prefectural Institute of Industrial Technology), Masakatsu Fujimoto (Yamaguchi Prefectural Industrial Technology Institute), Kenji Ishimatsu (Kumamoto Industrial Research Institute), Yasuhiro Ishida (Fukuoka Industrial Technology Center) EMCJ2010-113
EMI test sites above 1 GHz are modeled as a free space. CISPR has specified the site voltage standing wave ratio (site V... [more] EMCJ2010-113
pp.79-84
EMCJ 2009-01-23
13:00
Fukuoka   Depend on cable configuration for Radiated Electromagnetic Fielad from Multi-Pair Cable by Using Method of Moment
Naoki Kojima (Kyutech), Masato Kawabata (Fukuoka Industrial Technology Center), Nobuo Kuwabara (Kyutech) EMCJ2008-105
The radiated electromagnetic field from an UTP cable might become a problem of EMC because of an increase in the signal ... [more] EMCJ2008-105
pp.17-22
EMCJ 2009-01-23
14:55
Fukuoka   Reduction of Estimation Time for Distrubance Level Considering With Current and Magnetic-Current Source by Employing Majority decision
Masanori Kaneko, Nobuo Kuwabara (KIT), Yasuhiro Ishida (FITC) EMCJ2008-109
The maximum value of radiated emission must be measured at a distance of 10m by the CISPR publications. However, the tes... [more] EMCJ2008-109
pp.41-46
EMCJ 2009-01-23
16:50
Fukuoka   Evaluation of lightning strip protection area using FDTD method
Masato Kawabata (Fukuoka Industrial Technology Center), Taisuke Tokunaga, Masafumi Miyoshi, Yasuo Takahashi (KHI) EMCJ2008-113
A Radome is a weatherproof enclosure that protects antenna from rain and hail impact and so on. In any case, radomes are... [more] EMCJ2008-113
pp.65-70
EMCJ 2008-01-25
15:25
Saga Saga University Wire Grid Modeling method for parallel microstrip-line from 0.5 to 6GHz
Toshihisa Masuda, Nobuo Kuwabara (KIT), Masato Kawabata (Fukuoka Industrial Technology Center) EMCJ2007-114
The moment method is effective to analyze the electromagnetic field because the calculation time is shorter than that of... [more] EMCJ2007-114
pp.49-54
EMCJ 2008-01-25
16:00
Saga Saga University Calculation of Emitted Magnetic Feild Using Wire Grid Model Considering Dielectric Material of VVF Cable
Keisuke Nagamoto, Nobuo Kuwabara (KIT), Masato Kawabata (Fukuoka Industrial Technology Center) EMCJ2007-115
Power line communication (PLC) system has the merit that this need not prepare the transmission line and it is expected ... [more] EMCJ2007-115
pp.55-60
EMCJ 2007-11-16
15:40
Tokyo Tokyo Instutute of Technology FDTD Analysis of Site VSWR with Varying Absorber Arrangement and Area
Masataka Midori, Nobuo Kuwabara (Kyushu Institute of Technology), Masato Kawabata (Fukuoka Industrial Technology Center) EMCJ2007-95
The measurement site to measure electromagnetic interference for frequency band above 1GHz standardizes free space site ... [more] EMCJ2007-95
pp.77-82
EMCJ 2007-01-26
16:05
Kagoshima   Method of Far Field Estimation Considering with Unevenness of Radiation Source Modeling Results
Noriyuki Matuo, Yoshito Okubo, Nobuo Kuwabara (KIT), Masato Kawabata (Fukuoka Industrial Technology Center) EMCJ2006-109
The method have been studied to estimate radiated emission at distance of 10m by modeling the radiation source from the ... [more] EMCJ2006-109
pp.63-68
EMCJ 2006-01-16
15:05
Fukuoka Kyushu University Dependence on measurement facility for radiated emission prediction method at 10 m distance
Masato Kawabata, Yasuhiro Ishida (Fukuoka Industrial Technology Center), Nobuo Kuwabara (Kyushu Institute of Technology)
The radiated emission levels at a distance of 10 m are prescribed by the specification. Preliminary test for noise reduc... [more] EMCJ2005-133
pp.35-40
EMCJ 2006-01-16
15:45
Fukuoka Kyushu University Investigation on Radiated Emission Suppression Effect of Differential Transmission Mode from Printed Circuit Boards in Frequency Range of 0.5 GHz to 6 GHz
Ryota Mitote, Toshiro Nishimura, Nobuo Kuwabara (K.I.T), Masato Kawabata (Fukuoka Industrial Technology Center)
Emission suppression technology according with printed circuit board (PCB) is effective to reduce unwanted emission from... [more] EMCJ2005-134
pp.41-46
EMCJ 2005-09-09
13:40
Kyoto Kyoto University Improvement of Calculation Time for Estimating Electromagnetic Disturbance Level Using Radiation Source Modeling Method
Yoshito Okubo (KIT), Masato Kawabata, Yasuhiro Ishida (FITC), Nobuo Kuwabara (KIT)
It has been reported that, when we measures radiated emission based on the standard of information technology equipment,... [more] EMCJ2005-73
pp.85-90
EMCJ 2005-09-09
14:40
Kyoto Kyoto University Investigation of four-port network model for emitted electromagnetic field analysis from UTP cable more than 1GHz
Hiroto Tamaki (KIT), Yasuhiro Ishida (FITC), Nobuo Kuwabara (KIT)
When the speed of communication signal propagating through a UTP cable goes high, electromagnetic field radiated from a ... [more] EMCJ2005-75
pp.97-102
EMCJ 2005-01-20
09:05
Okinawa NiCT Okinawa Subtropical Environment Remote Sensing Center Study of Dual Antenna Mast Measurement System in a Semi-anechoic Chamber
Yashuhiro Ishida (ADOX Fukuoka), Kazuo Shimada (Riken Eletech), Hiroyuki Shimanoe (Fujitsu General EMC), Masato Kawabata (Fukuoka Industrial Tech Center)
In order to shorten measuring time of undesired emission radiated from electronic or electric equipment, DAMMS (Dual Ant... [more] EMCJ2004-117
pp.1-6
EMCJ 2005-01-20
10:20
Okinawa NiCT Okinawa Subtropical Environment Remote Sensing Center Investigation of source modeling conditions for prediction of radiated emission at 10 m distance
Masato Kawabata (FITC), Noburo Aoki (KIT), Yasuhiro Ishida (FITC), Nobuo Kuwabara (KIT)
It is difficult to predict the radiated emission at 10 m distance from the data at 3 m distance. The source modeling con... [more] EMCJ2004-120
pp.19-24
 Results 1 - 17 of 17  /   
Choose a download format for default settings. [NEW !!]
Text format pLaTeX format CSV format BibTeX format
Copyright and reproduction : All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034)


[Return to Top Page]

[Return to IEICE Web Page]


The Institute of Electronics, Information and Communication Engineers (IEICE), Japan