Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
EMD |
2016-11-03 13:30 |
Hyogo |
Awaji Yumebutai International Conference Center |
Molybdenum Disulfide Lubricant for Copper-copper Electrical Sliding Contacts Tomoharu Ootsuka, Yoshitada Watanabe, Koichiro Sawa, Takahiro Ueno (NIT) EMD2016-51 |
Sliding contacts are an important mechanical feature of various types of equipment including motors, electric trains, an... [more] |
EMD2016-51 pp.5-9 |
EMD |
2016-11-03 13:55 |
Hyogo |
Awaji Yumebutai International Conference Center |
Degradation Phenomenon of Electrical Contacts by using a Micro-Sliding Mechanism
-- The comparison with input waveforms concerning of minimal sliding amplitudes under some conditions 2 -- Shin-ichi Wada, Keiji Koshida (TMC), Koichiro Sawa (NIT) EMD2016-52 |
Authors have studied degradation phenomenon on electrical contacts under the influences of an external micro-oscillation... [more] |
EMD2016-52 pp.11-16 |
EMD |
2016-11-03 15:25 |
Hyogo |
Awaji Yumebutai International Conference Center |
Dependence of Arc Duration of Break Arcs Magnetically Blown-out on Contact Material in 200V-450VDC/10A Circuit Akinori Ishihara, Junya Sekikawa (Shizuoka Univ.) EMD2016-55 |
Electrical contacts are separated at constant speed and break arcs are generated in a 200V-450VDC/10A resistive circuit.... [more] |
EMD2016-55 pp.29-34 |
EMD |
2016-11-04 11:00 |
Hyogo |
Awaji Yumebutai International Conference Center |
Effect of Magnetic Blow-out of Break Arcs with air flow Occurring between Silver Electrical Contacts with Copper Runners Haruki Miyagawa, Junya Sekikawa (Shizuoka Univ) EMD2016-61 |
Arc runners are fixed on silver electrical contacts. Break arcs are generated between the contacts in a 450VDC circuit. ... [more] |
EMD2016-61 pp.63-68 |
EMD |
2016-11-04 11:25 |
Hyogo |
Awaji Yumebutai International Conference Center |
Restriction of Motion of Break Arcs Being Magnetically Blown-out by Side Surface of Metal Plates Yu Ota, Junya Sekikawa (Shizuoka Univ.) EMD2016-62 |
Silver contacts are separated at constant speed and break arcs are generated in the DC supply voltage 200V-450V and resi... [more] |
EMD2016-62 pp.69-74 |
EMD |
2016-11-04 11:50 |
Hyogo |
Awaji Yumebutai International Conference Center |
Calculation of Thermodynamic and Transport Properties of Arc Plasma occurring between Ag and C contacts Akifumi Ikegami, Junya Sekikawa (Shizuoka Univ) EMD2016-63 |
For break arcs occurring between carbon(graphite) electrical contacts, the electrical conductivity, the viscosity, speci... [more] |
EMD2016-63 pp.75-79 |
EMD, CPM, OME |
2016-06-17 16:45 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
Electrical Measurements on Organic Single Crystals by Using Lamination Contact Electrode Masatoshi Sakai, Yusaku Tada, Taiga Goto, Yugo Okada, Hiroshi Yamauchi, Kazuhiro Kudo (Chiba Univ.) EMD2016-16 CPM2016-23 OME2016-26 |
In this study, we have developed and demonstrated a novel electrical contact method for organic single crystals. Au elec... [more] |
EMD2016-16 CPM2016-23 OME2016-26 pp.43-44 |
EMD |
2016-05-20 13:35 |
Hokkaido |
Chitose Arcadia Plaza |
Occurring Conditions of Successive Reignitions of Break Arcs being Magnetically Blown-out with Copper Runners Haruki Miyagawa, Junya Sekikawa (Shizuoka Univ) EMD2016-1 |
Copper arc runners are fixed on silver electrical contacts. Break arcs being magnetically blown-out of are generated bet... [more] |
EMD2016-1 pp.1-6 |
EMD |
2016-05-20 14:00 |
Hokkaido |
Chitose Arcadia Plaza |
Restriction on Moving by Iron, Copper and Aluminum Plate Sides of Break Arcs Occurring between Silver Electrical Contacts Yu Ota, Junya Sekikawa (Shizuoka Univ.) EMD2016-2 |
Iron, copper, Aluminum plates is fixed on top of the between silver electrical contacts gap. Break arcs are generated be... [more] |
EMD2016-2 pp.7-11 |
EMD |
2016-05-20 14:50 |
Hokkaido |
Chitose Arcadia Plaza |
Influence of electrical contact material on breaking characteristics of arc discharge at DC high voltage
-- Experimental results from DC200 to 500V of various materials -- Kiyoshi Yoshida, Koichiro Sawa, Hikaru Kanou, Hiroto Yamagishi (NIT), Kenji Suzuki, Koetsu Takaya (Fuji FA Comp.& Sys.) EMD2016-4 |
The experimental apparatus that is able to set opening velocity at wide-range of 1-200mm/s with an equal speed was used ... [more] |
EMD2016-4 pp.19-24 |
EMD |
2016-03-04 14:55 |
Saitama |
|
Influence of Opening Velocity and Contact Material on Various Characteristics in Break Arc Hikaru Kanou, Hiroto Yamagishi, Koichiro Sawa, Kiyoshi Yoshida (NIT) EMD2015-104 |
The experimental apparatus that is able to set opening velocity at wide-range of 1-200mm/s with an equal speed was used ... [more] |
EMD2015-104 pp.21-24 |
EMD |
2016-03-04 15:15 |
Saitama |
|
Influences of Make Arc on Various Characteristics and Electrode Mass Change for Electromagnetic Contactor Yuuki Takahadhi, Yuuta Higan, Koichiro Sawa, Kiyoshi Yoshida (NIT) EMD2015-105 |
Experiments were carried out to clarify the influence of closed contact current on various characteristics, such as arc ... [more] |
EMD2015-105 pp.25-28 |
EMD |
2016-01-22 14:25 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
Restriction on Moving by an Iron Plate Side of Break Arcs Occurring between Ag Electrical Contacts Yu Ota, Haruki Miyagawa, Junya Sekikawa (Shizuoka Univ.) EMD2015-89 |
An Iron plate is fixed on top of the between Ag electrical contacts gap. Break arcs are generated between the contacts i... [more] |
EMD2015-89 pp.11-15 |
EMD |
2015-11-05 14:05 |
Miyagi |
Tohoku University, School of engineering, Aoba memorial hall |
Various Characteristics of Electromagnetic Contactor with Make Arc
-- Influence of Closed Contacts Current -- Shu Shimotsuma, Kiyoshi Yoshida, Koichiro Sawa (NIT), Kenji Suzuki, Koetsu Takaya (Fuji FA Comp. & systems) EMD2015-67 |
Experiments at several load currents have been carried out to clarify the various characteristics of AgNi contacts with ... [more] |
EMD2015-67 pp.1-6 |
EMD |
2015-11-05 14:55 |
Miyagi |
Tohoku University, School of engineering, Aoba memorial hall |
Magnetic Blow-out of Break Arcs Occurring between Silver Electrical Contacts with Copper Runners Haruki Miyagawa, Junya Sekikawa (Shizuoka Univ) EMD2015-69 |
Arc runners are fixed on silver electrical contacts. Break arcs are generated between the contacts in a 450VDC circuit. ... [more] |
EMD2015-69 pp.11-16 |
EMD |
2015-11-06 09:30 |
Miyagi |
Tohoku University, School of engineering, Aoba memorial hall |
Calculation of Thermodynamic and Transport Properties of Arc Plasma for different Mixture Rates of Silver Metallic Vapor Akifumi Ikegami, Junya Sekikawa (Shizuoka Univ.) EMD2015-74 |
In Order to know in detail discharge characteristics of a break arc occurring between electrical contacts, understanding... [more] |
EMD2015-74 pp.41-45 |
EMD |
2015-10-02 16:50 |
Saitama |
Fuji Electric FA Components & SystemCo.,Ltd. |
Degradation Phenomenon of Electrical Contacts by using a Micro-Sliding Mechanism
-- The comparison with input waveforms concerning of minimal sliding amplitudes under some conditions -- Shin-ichi Wada, Keiji Koshida (TMC), Koichiro Sawa (NIT) EMD2015-66 |
Authors have studied the degradation phenomenon on contact resistance under the influences of an external micro-oscillat... [more] |
EMD2015-66 pp.37-42 |
EMD, CPM, OME |
2015-06-19 15:55 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
By means of a statistical method an analysis of degradation phenomenon of electrical contacts using micro-sliding mechanisms
-- A statistical analysis using data of minimal sliding amplitudes under some conditions -- Keiji Koshida, Shin-ichi Wada, Hiroaki Kubota (TMC), Koichiro Sawa (NIT) EMD2015-17 CPM2015-27 OME2015-30 |
Authors have designed and developed a mechanism to be capable of micro-sliding electrical contact directly by using a gi... [more] |
EMD2015-17 CPM2015-27 OME2015-30 pp.35-40 |
EMD, CPM, OME |
2015-06-19 16:45 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
An experimental study on break arc characteristics of AgSnO2 contact pairs at interruptions of DC load currents with different contact opening speeds Makoto Hasegawa (Chitose Inst. of Science & Technology) EMD2015-19 CPM2015-29 OME2015-32 |
In DC load circuit conditions with a power supply voltage of DC14V, break operations of a load current in the range from... [more] |
EMD2015-19 CPM2015-29 OME2015-32 pp.47-50 |
EMD |
2015-05-15 14:00 |
Akita |
Akita University Tegata Campus |
Influence of Current on Electrode Mass Change of AgNi Contacts for Electromagnetic Contactor
-- Various characteristics of contactor with only break arc -- Kiyoshi Yoshida, Koichiro Sawa (NIT), Kenji Suzuki, Hideki Daijima, Koetsu Takaya (Fuji Elec. FA&Sys.) EMD2015-2 |
Experiments were carried out to clarify the influence of closed contact current on various characteristics, such as arc ... [more] |
EMD2015-2 pp.7-12 |