IEICE Technical Committee Submission System
Conference Schedule
Online Proceedings
[Sign in]
Tech. Rep. Archives
    [Japanese] / [English] 
( Committee/Place/Topics  ) --Press->
 
( Paper Keywords:  /  Column:Title Auth. Affi. Abst. Keyword ) --Press->

All Technical Committee Conferences  (Searched in: All Years)

Search Results: Conference Papers
 Conference Papers (Available on Advance Programs)  (Sort by: Date Descending)
 Results 61 - 80 of 302 [Previous]  /  [Next]  
Committee Date Time Place Paper Title / Authors Abstract Paper #
EA, ASJ-H, ASJ-AA 2019-07-17
13:00
Hokkaido SAPPORO COMMUNITY PLAZA Extension of acoustic measurement procedures based on frequency domain variants of the velvet noise
Hideki Kawahara (Wakayama Univ.), Ken-Ichi Sakakibara (Health Science Univ.), Mitsunori Mizumachi (Kyutech) EA2019-15
The frequency domain velvet noise (FVN) is a member of the time stretched pulse (TSP) in the broader sense
because the... [more]
EA2019-15
pp.77-82
SANE 2019-04-16
11:30
Kanagawa Defense Academy; Defense Training Institute The Calibration Method for the Distributed Array Radar using Reflected Signal from a Moving Target
Toshihiro Ito, Shoji Matsuda, Nobuhiro Suzuki, Toshio Wakayama (Mitsubishi Electric) SANE2019-6
Distributed array radar consists of multiple subarrays which is relatively small phased array antenna. Because of the sm... [more] SANE2019-6
pp.27-32
PRMU, CNR 2019-03-01
14:00
Tokushima   Camera Calibration Based on Angle Detection that Uses Vanishing Point
Shuichi Utsugi (Salesian Pokytechnic), Hisashi Suzuki (Chuo Univ.) PRMU2018-132 CNR2018-55
In camera calibration which is a nonlinear least squares problem, to get a correct rotation matrix is important and diff... [more] PRMU2018-132 CNR2018-55
pp.99-104
AP 2019-02-21
15:20
Osaka Sumitomo Electric Industries (Osaka Works) [Invited Lecture] Direction of Arrival Estimation with the Calibration Method Based on an Excitation Condition for an Antenna Array
Makoto Higaki, Kentaro Murata, Makoto Sano (Toshiba Corp.) AP2018-175
We have seen the advent of various wireless communication systems, e.g. cellular system, wireless LAN, Bluetooth, RFID s... [more] AP2018-175
pp.31-36
MW 2018-12-13
16:35
Kanagawa Kanagawa Univ. On low-frequency anomalies of S-parameters of coaxial lines
Ken Shobe, Shuhei Amakawa (Hiroshima Univ.) MW2018-126
Transmission coefficients of reciprocal and passive devices such astranssmission lines always show phasedelays. However,... [more] MW2018-126
pp.73-78
SIS 2018-12-07
10:10
Yamaguchi Hagi Civic Center A Proposal of Color Calibration Method Which Suppresses False Color for Images Taken by Different Imaging Conditions
Shi Bao (Inner Mongolia Univ. of Tech.), Go Tanaka (Nagoya City Univ.) SIS2018-31
In recent years, color calibration methods for two color images taken under different imaging conditions are investigate... [more] SIS2018-31
pp.51-54
MW 2018-11-16
09:40
Nagasaki Fukue Cultural Hall A Study on Measurement of Microwave Absorber by Free Space Method
Masaya Suzuki, Masahiro Hanazawa (UL Japan), Hiromi Shima, Toshihisa Kamei (NDA) MW2018-105
A Free Space Method is one of measurement method for analyzing properties of reflection, transmission and absorption.
T... [more]
MW2018-105
pp.67-70
PRMU, IBISML, IPSJ-CVIM [detail] 2018-09-21
13:30
Fukuoka   Modification of Bayesian Optimization for Efficient Calibration of Simulation Model
Daiki Kiribuchi, Takeichiro Nishikawa (Toshiba), Satoru Yokota, Ryota Narasaki, Soh Koike (Toshiba Memory) PRMU2018-63 IBISML2018-40
(To be available after the conference date) [more] PRMU2018-63 IBISML2018-40
pp.195-200
AP, SANE, SAT
(Joint)
2018-07-20
11:10
Hokkaido Hokkaido Univ. Modified Calibration Technique of Distance Property for Electric Field Intensity Radiated by Small Dipole Antenna Operated in Solution
Nozomu Ishii (Niigata Univ.), Chakarothai Jerdvisanop, Kanako Wake, Lira Hamada, Soichi Watanabe (NICT) AP2018-62 SANE2018-26 SAT2018-21
The authors have determined the transmit antenna factor of a reference dipole antenna as a function of the distance by t... [more] AP2018-62 SANE2018-26 SAT2018-21
pp.119-124(AP), pp.25-30(SANE), pp.61-66(SAT)
MW
(2nd)
2018-06-27
- 2018-06-29
Overseas KMITL, Bangkok, Thailand Calibration of a reflectometer with a pattern reconfigurable antenna
Nichchan Jiaranai, Chainarong Kittiyanpunya (RMUTR), Monai Krairiksh (KMITL)
This paper describes a calibration of a reflectometer by using a pattern reconfigurable antenna. The pattern reconfigura... [more]
MW
(2nd)
2018-06-27
- 2018-06-29
Overseas KMITL, Bangkok, Thailand [Poster Presentation] Ground-Penetrating Radar Imaging with Antenna Calibration-assisted Improvement for Buried-object Detection
Lakkhana bannawat, tripop tongboonsong, Akkarat boonpoonga (KMUTNB)
This paper presents an improvement of the vertical resolution of a ground penetrating radar (GPR) image. The near-field ... [more]
SIS, IPSJ-AVM, ITE-3DMT [detail] 2018-06-08
10:50
Hokkaido Jozankei View Hotel A Proposal of Color Calibration Method Based on Iterative Distribution Transfer and Projection for Images Taken by Different Imaging Conditions
Shi Bao (Inner Mongolia Univ. of Tech.), Go Tanaka (Nagoya City Univ.) SIS2018-6
In recent years, color calibration methods for two color images taken under different imaging conditions are investigate... [more] SIS2018-6
pp.59-62
SIP, EA, SP, MI
(Joint) [detail]
2018-03-20
16:45
Okinawa   Geometry calibration method based on point-cloud registration for a portable X-ray system
Takuya Kato, Takashi Ohnishi, Masashi Sekine, Hideaki Haneishi (Chiba Univ.) MI2017-106
Tomosynthesis is a medical image modality that can acquire tomographic images at low doses compared to X-ray CT. In this... [more] MI2017-106
pp.145-148
SIS 2018-03-09
11:50
Aichi Meijo Univ. Tempaku Campus A Proposal of Color Calibration Method Between Different Cameras Based on Nonlinear Projection
Yoshiaki Ueda, Kazuki Yamada (Yamaguchi Univ.), Go Tanaka (Nagoya City Univ.), Hideaki Misawa (NIT, Ube College), Takanori Koga (NIT, Tokuyama College), Noriaki Suetake, Eiji Uchino (Yamaguchi Univ.) SIS2017-67
In general, images taken by different cameras show different color reproduction even if these cameras are same model. To... [more] SIS2017-67
pp.57-62
ICD, MW 2018-03-01
15:15
Shiga The University of Shiga Prefecture [Poster Presentation] A Study of Impedance Mismatch for S-parameter Measurement using Network Analyzer
Takuichi Hirano (Tokyo Tech) MW2017-185 ICD2017-109
S parameters of high frequency circuits are measured by a network analyzer. Calibration is performed before measurement ... [more] MW2017-185 ICD2017-109
p.55
HPB
(2nd)
2018-02-21
11:20
Tokyo   Accurate Value Fluctuation Acquisition Method using Inexpensive and Uncertain CO2 Sensor
Tsuyoshi Wada, Masayuki Iwai (TDU)
To measure carbon dioxide concentration in many rooms, a large amount of CO$_2$ sensor is required.
The CO$_2$ sensor i... [more]

AP 2018-02-15
15:00
Tokyo Kozo Keikaku Engineering, Inc. [Tutorial Lecture] Phased Array Calibration Based on Phase Modulation of Individual Element Antenna
Toru Takahashi (Mitsubishi Electric) AP2017-179
This report has focused on phased array calibration, especially element-field measurement technologies based on phase mo... [more] AP2017-179
pp.19-24
SR 2018-01-26
10:55
Fukuoka Fukuoka univ. A Calibration Method for Crowdsensing Based Radio Environment Database
Miho Ito, Keita Onose, Koya Sato (UEC), Kei Inage (TMCIT), Takeo Fujii (UEC) SR2017-103
In spectrum sharing with cognitive radio, radio environment estimation is essential to secure quality of unlicensed user... [more] SR2017-103
pp.57-62
AP, WPT
(Joint)
2018-01-19
14:30
Nara ATR A Study on Phased-Array Calibration with Amplitude-Only Measurements
Toru Takahashi (Mitsubishi Electric) AP2017-168
A novel amplitude-only measurement method has been proposed to measure each element field for phased-array calibration. ... [more] AP2017-168
pp.99-104
PRMU, MVE, IPSJ-CVIM [detail] 2018-01-19
09:30
Osaka   Motion Capture from Multi-View Mobile Cameras
Daisuke Kubayashi, Igarashi Takashi, Masanobu Yamamoto (Niigata Univ.) PRMU2017-132 MVE2017-53
Capturing human body motion with a multi-view camera system, the measurable range is a common field of view from each ca... [more] PRMU2017-132 MVE2017-53
pp.203-208
 Results 61 - 80 of 302 [Previous]  /  [Next]  
Choose a download format for default settings. [NEW !!]
Text format pLaTeX format CSV format BibTeX format
Copyright and reproduction : All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034)


[Return to Top Page]

[Return to IEICE Web Page]


The Institute of Electronics, Information and Communication Engineers (IEICE), Japan