IEICE Technical Committee Submission System
Conference Schedule
Online Proceedings
[Sign in]
Tech. Rep. Archives
    [Japanese] / [English] 
( Committee/Place/Topics  ) --Press->
 
( Paper Keywords:  /  Column:Title Auth. Affi. Abst. Keyword ) --Press->

All Technical Committee Conferences  (Searched in: All Years)

Search Results: Conference Papers
 Conference Papers (Available on Advance Programs)  (Sort by: Date Descending)
 Results 61 - 80 of 122 [Previous]  /  [Next]  
Committee Date Time Place Paper Title / Authors Abstract Paper #
EMD 2013-03-01
15:35
Saitama Nippon Institute of Technology Damage shape evaluation system of electrical contacts and investigation of material transfer and erosion phenomena
Keisuke Takahashi, Daichi Kawamura, Yuya Hirano, Makoto Hasegawa (Chitose Inst. of Science and Tech.) EMD2012-118
Contact surfaces of mechanical relays and switches are often damaged by arc discharges and/or mechanical wear during swi... [more] EMD2012-118
pp.37-40
EMD 2013-01-25
15:50
Kanagawa Hitachi, Ltd., (Totsuka, Yokohama) An experimental study on a 3-D shape observation system of a sample by employing a laser displacement sensor
Makoto Hasegawa, Daichi Kawamura, Keisuke Takahashi (Chitose Inst. of Science and Tech.) EMD2012-100
For the purpose of observing and evaluating damaged shapes due to material transfer and erosion, caused by arc discharge... [more] EMD2012-100
pp.15-19
EMD 2012-12-21
13:05
Tokyo Kikai-Shinko-Kaikan Bldg. [Special Talk] Arc V-I Characteristics and Their Measuring Method -- From a Viewpoint of Applying Them on Break Arc Voltage and Current Calculation --
Keiichi Suhara (TNCT) EMD2012-91
Arc V-I Characteristics are necessary for calculation of voltage and current in electric circuit involving arc discharge... [more] EMD2012-91
pp.1-6
EMD 2012-11-30
10:45
Chiba Chiba Institute of Technology Arc Length of Break Arcs Magnetically Blown-out at Arc Extinction
Hitoshi Ono, Junya Sekikawa (Shizuoka Univ.) EMD2012-66
Silver electrical contacts are separated at constant speed and break arcs are generated in a DC300V-450V/10A resistive c... [more] EMD2012-66
pp.13-18
EMD 2012-11-30
14:10
Chiba Chiba Institute of Technology Observation of growth of arc damages on Ag and AgSnO2 contact surfaces during switching operations
Keisuke Takahashi, Makoto Hasegawa (Chitose Inst. of Science and Tech.) EMD2012-69
An evaluation system for contact surface damages is being constructed so as to realize observation of a changing process... [more] EMD2012-69
pp.31-36
EMD 2012-11-30
14:30
Chiba Chiba Institute of Technology Arc Erosion of Carbon Contacts in Bio-fuels for Automobille
Cheng Chan Wei, Koichiro Sawa, Takahiro Ueno (Nippon Inst. of Tech.) EMD2012-70
In a DC motor, arcing occurs during commutation, which causes wear of commutator and brush . This is often one of practi... [more] EMD2012-70
pp.37-41
EMD 2012-11-30
14:50
Chiba Chiba Institute of Technology Relation between Electrode Mass Change and Arc Energy of AgNi Contacts for Electromagnetic Contactors
Kiyoshi Yoshida, Koichiro Sawa (Nippon Inst. of Tech.), Kenji Suzuki, Hideki Daijima, Koetsu Takaya (Fuji Electric) EMD2012-71
Experiments were carried out at several voltages to clarify the influence of the voltage on various characteristics, i.e... [more] EMD2012-71
pp.43-48
EMD 2012-10-19
15:15
Tokyo Fuji Electric FA Components & Systems Co., Ltd. Three dimensional evaluation of arc damages on Ag and AgSnO2 contact surfaces
Keisuke Takahashi, Makoto Hasegawa (Chitose Inst. of Science and Technology) EMD2012-63
Material transfer and erosion caused by arc discharges during operations of mechanical relays and switches is one of cri... [more] EMD2012-63
pp.19-24
OCS, OFT
(Joint)
2012-08-31
13:10
Hokkaido   Refractive Index Profile Changes Caused by Arc Discharge in Arc-Induced Long-Period Fiber Gratings
Fatemeh Abrishamian (Osaka Electro-Comm. Univ.), Nicoleta Dragomir (Victoria Univ.), Katsumi Morishita (Osaka Electro-Comm. Univ.) OFT2012-25
Long-period fiber gratings were inscribed in a commercial silica fiber by a point-by-point arc discharge technique with ... [more] OFT2012-25
pp.33-38
EMCJ, EMD 2012-07-20
13:40
Tokyo Kikai-Shinko-Kaikan Bldg. Magnetically Blowing out of Break Arcs Restricted by the Wall
Hitoshi Ono, Junya Sekikawa (Shizuoka Univ) EMCJ2012-43 EMD2012-18
Silver contacts are separated at constant speed and break arc are generated in a DC200-450V and 10A resistive circuit. T... [more] EMCJ2012-43 EMD2012-18
pp.13-18
EMD 2012-05-25
13:55
Miyagi Tohoku Bunka Gakuen Univ. Influence of Source Voltage on Electrode Mass Change of AgNi Contacts for Electromagnetic Contactor -- Various characteristics of contactor with only make arc --
Kiyoshi Yoshida, Koichiro Sawa (NIT), Kenji Suzuki, Hideki Daijima, Koetsu Takaya (Fuji Electric) EMD2012-2
Experiments at several source voltages have been carried out to clarify the influence of the voltage on various characte... [more] EMD2012-2
pp.7-12
EMCJ, ITE-BCT 2012-03-16
15:15
Tokyo Kikai-Shinko-Kaikan Bldg. Effect of holder temperature on bridge and arc at slowly breaking contact
Kazuaki Miyanaga, Yoshiki Kayano, Hiroshi Inoue (Akita Univ.) EMCJ2011-142
The electrical contact is wideband noise source. But the electrical contact is essential device for the electrical circu... [more] EMCJ2011-142
pp.73-77
EMD 2012-03-02
13:30
Tokyo Tanagawa Univ. V-I Characteristics and Extinction Characteristics of Arcs between Copper Electrodes
Godwill Mbiti, Keiichi Suhara (TNCT) EMD2011-130
V-I characteristics of Arcs is needed to properly analyze electrical circuits that include arc discharge. Guye’s researc... [more] EMD2011-130
pp.17-20
EMD, R 2012-02-17
11:00
Kyoto   An experimental study on contact resistance characteristics of relay contacts operated in the vicinity of a new acryl-based polymer
Makoto Hasegawa, Nanae Kobayashi (Chitose Inst. of Science and Technology), Yoshiyuki Kohno, Hiroshi Ando (Kaneka Corp.) R2011-43 EMD2011-117
The authors have already reported that when relays were operated to break load currents in vapors evaporated from a newl... [more] R2011-43 EMD2011-117
pp.7-12
EMD, R 2012-02-17
11:25
Kyoto   An experimental study on an optical measurement system for damages on contact surfaces
Keisuke Takahashi, Makoto Hasegawa (Chitose Inst. of Science and Technology) R2011-44 EMD2011-118
Contact surfaces of mechanical relays and switches are often damaged by arc discharges and/or mechanical wear during swi... [more] R2011-44 EMD2011-118
pp.13-18
EMD 2011-12-16
13:05
Tokyo NIT Kanda Camps A Review of Measured V-I Characteristics of Arcs between Metallic Electrodes -- Comparison with Values Experimentally Measured by C.E.Guye and L.Zebrikoff --
Keiichi Suhara (TNCT) EMD2011-106
Ayrton equation is famous for an expression of arc V-I characteristics. Guye and Zebrikoff studied the Ayrton constants ... [more] EMD2011-106
pp.1-3
EMD 2011-11-17
08:45
Akita Akita Univ. Tegata Campus Reignition of Break Arcs Magnetically Blown-Out in a 450V DC Resistive Circuit
Hitoshi Ono, Junya Sekikawa, Takayoshi Kubono (Shizuoka Univ) EMD2011-66
Silver electrical contacts are separated at constant speed and break arc are generated in a DC450V-10A resistive circuit... [more] EMD2011-66
pp.1-6
EMD 2011-11-17
16:50
Akita Akita Univ. Tegata Campus An Experimental Study on Evaluation of Contact Surface Damages with an Optical Cross-Section Method
Keisuke Takahashi, Makoto Hasegawa (Chitose Inst. of Science & Tech.) EMD2011-84
Contact surfaces of mechanical relays and switches are often damaged by arc discharges and/or mechanical wear during swi... [more] EMD2011-84
pp.91-96
EMD 2011-11-17
17:10
Akita Akita Univ. Tegata Campus Contact Resistance Characteristics of Relays Operated in Vapors Evaporated from Cured Polymeric Products
Nanae Kobayashi, Makoto Hasegawa (Chitose Inst. of Science & Tech.), Yoshiyuki Kohno, Hiroshi Ando (Kaneka) EMD2011-85
The authors have already reported that when relays were operated to break load currents in vapors evaporated from an acr... [more] EMD2011-85
pp.97-102
EMD 2011-11-18
16:50
Akita Akita Univ. Tegata Campus Experimental Analysis of Transient Phenomena from Metal Melting to Electric Discharge during Breaking Operations of Electric Contacts
Takayuki Kudo, Noboru Wakatsuki (Ishinomaki Senshu Univ.) EMD2011-103
During breaking contact, contact voltage vc shows irregular, random, or unexpected responses after vc=Um until mechanica... [more] EMD2011-103
pp.195-200
 Results 61 - 80 of 122 [Previous]  /  [Next]  
Choose a download format for default settings. [NEW !!]
Text format pLaTeX format CSV format BibTeX format
Copyright and reproduction : All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034)


[Return to Top Page]

[Return to IEICE Web Page]


The Institute of Electronics, Information and Communication Engineers (IEICE), Japan