Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
HCGSYMPO (2nd) |
2023-12-11 - 2023-12-13 |
Fukuoka |
Asia pacific Import Mart (Kitakyushu) (Primary: On-site, Secondary: Online) |
Estimating the amount of METs based on human physical activity data using wearable device Minami Ishihara, Yuya Itagaki, Yuukou Horita (Univ. of Toyama) |
Accurate measurement of the METS (unit: sitting at rest = 1 METS), which represents the intensity of physical activity t... [more] |
|
SRW, SeMI (Joint) |
2023-11-21 14:35 |
Tokyo |
Koganei Campus, Tokyo University of Agriculture and Technology (Primary: On-site, Secondary: Online) |
[Short Paper]
IoT-Based UV Measurement Devices and Visualization Systems in Stationary or Moving State Yuto Masuyama, Masayuki Iwai (TDU) SeMI2023-44 |
In recent years, while climate change is occurring in many parts of the world due to the effects of global warming, ther... [more] |
SeMI2023-44 pp.17-22 |
SRW, MICT, WBS |
2023-07-20 11:00 |
Niigata |
Niigata Univ. TOKIMATE (Primary: On-site, Secondary: Online) |
Motion artifact removal in R-R interval estimation of ECG signal for wearable biomedical sensors using adaptive filter and highpass filter Yohei Arakawa, Tadao Nakagawa (Tottori Univ.) WBS2023-13 SRW2023-11 MICT2023-10 |
The development of medical technology has facilitated the acquisition of biomedical information such as electrocardiogra... [more] |
WBS2023-13 SRW2023-11 MICT2023-10 pp.1-6 |
EST, MW, EMT, OPE, MWPTHz, IEE-EMT [detail] |
2023-07-20 13:00 |
Hokkaido |
Muroran Institute of Technology (Primary: On-site, Secondary: Online) |
Numerical Evaluation of Electrocardiograms due to Variation of Morphology and Electrode Position Kazuki Hebiguchi, Sachiko Kodera, Akimasa Kodera (NITech) EMT2023-15 MW2023-33 OPE2023-15 EST2023-15 MWPTHz2023-11 |
Recent advance of a wearable device includes the bipolar electrocardiograph, which consists of two electrodes attached t... [more] |
EMT2023-15 MW2023-33 OPE2023-15 EST2023-15 MWPTHz2023-11 pp.32-37 |
RCS, SR, SRW (Joint) |
2023-03-02 11:15 |
Tokyo |
Tokyo Institute of Technology, and Online (Primary: On-site, Secondary: Online) |
Motion artifact removal in R-R interval estimation of ECG signal for wearable biomedical sensors using slope information and adaptive filters Yohei Arakawa, Tadao Nakagawa (Tottori Univ.) SRW2022-52 |
The development of medical technology has facilitated the acquisition of biomedical information such as electrocardiogra... [more] |
SRW2022-52 pp.47-51 |
MICT, EMCJ (Joint) |
2022-03-04 14:45 |
Online |
Online |
[Special Talk]
Conducted Disturbance Voltage Measurement Using Capacitive Coupling between Measurement Equipment and Ground Plane Naruto Arai (NTT EAST Corp.) EMCJ2021-76 |
Conducted disturbance originating from power supply equipment disrupts telecommunication networks and causes problems su... [more] |
EMCJ2021-76 p.20 |
SR |
2022-01-25 14:10 |
Online |
Online |
[Short Paper]
Measurement of propagation attenuation of standing user for directional WBAN Renta Fukui, Kohei Akimoto, Teruo Tobana (Akita Pref. Univ.) SR2021-80 |
Wireless body area network (WBAN) is a communication system between wearable devices for medical, sports, and entertainm... [more] |
SR2021-80 p.102 |
MW |
2021-11-18 15:25 |
Kagoshima |
Kagoshima University (Primary: On-site, Secondary: Online) |
Development of 1mW Class Rectenna for 920-MHz Band Wireless Power Transfer System Katsumi Kawai, Naoki Shinohara, Tomohiko Mitani (Kyoto Univ.) MW2021-71 |
The time and effort required to replace and recharge the batteries of wearable devices has become a problem in medical a... [more] |
MW2021-71 pp.24-28 |
EMCJ, MICT (Joint) |
2021-03-05 10:55 |
Online |
Online |
Measurement of Pulse Transmission Time and Estimation of Systolic Blood Pressure Using a Cervical Lead Device Kunito Tani, Ryuta Mizuguchi, Yuji MIzuno, Masafumi Matsumura (Osaka Electro-Communication Univ.) MICT2020-34 |
Currently, hypertension is the cause of cardiovascular disease, which accounts for one-fourth of the causes of death. Co... [more] |
MICT2020-34 pp.7-10 |
WIT, HI-SIGACI |
2019-12-04 10:50 |
Tokyo |
AIST Tokyo Waterfront (TBD) |
Relaxation support system using olfactory stimuli
-- Study on stress estimation and mitigation method based on the heart rate measurement -- Miyu Sekine, Syunnichi Yonemura (SIT) WIT2019-34 |
In this study, we propose a relaxation support system to reduce mental stress using aromatherapy room refusers. In thes... [more] |
WIT2019-34 pp.13-18 |
MBE |
2019-05-19 15:00 |
Niigata |
Niigata University |
Examination of Heartrate Measurement Method considering non-Invasiveness to Various Needs of People with Developmental Disorders Masahito Nagamori, Akina Nakamura, Kenta Imai, Miwako Fukuda, Akira Shionoya (NUT), Hitoshi Miyake (TMC) MBE2019-11 |
We are developing an e-portfolio system to support intentions with rational considerations. The feature of the system is... [more] |
MBE2019-11 pp.57-59 |
PRMU, MVE, IPSJ-CVIM [detail] |
2019-01-18 10:00 |
Kyoto |
|
Variable Motion Indication for On-Neck Communication
-- variation and selection with wrist-watch type device -- Takahide Ito, Kazuaki Kondo, Yuichi Nakamura (Kyoto Univ.), Jonathan Rossiter (Bristol Univ.), Junichi Akita (Kanazawa Univ.), Masashi Toda (Kumamoto Univ.) PRMU2018-106 MVE2018-48 |
今後の英語論文投稿時に二重投稿と判断されないよう、今回は英文のアブストラクトを省略したい。 [more] |
PRMU2018-106 MVE2018-48 pp.115-120 |
PRMU, MI, IE, SIP |
2018-05-17 16:15 |
Gifu |
|
Motion Monitoring using Skin-Stretcher Device Takahide Ito, Kazuaki Kondo, Yuichi Nakamura (Kyoto Univ.), Jonathan Rossiter (Bristol Univ.), Junichi Akita (Kanazawa Univ.), Masashi Toda (Kumamoto Univ.) SIP2018-5 IE2018-5 PRMU2018-5 MI2018-5 |
This paper introduces a novel design of a motion monitoring system through neck muscle measurement and skin-stretch stim... [more] |
SIP2018-5 IE2018-5 PRMU2018-5 MI2018-5 pp.17-22 |
MBE, NC, NLP (Joint) |
2018-01-27 11:45 |
Fukuoka |
Kyushu Institute of Technology |
Implementation and Evaluation of Lifelog Application using Wristwatch-Type Wearable Heart Rate Sensor Yudai Iida, Ryota Horie (SIT) MBE2017-74 |
To aim to measure a daily stress level, we report implementation and evaluation of a lifelog application using a wristwa... [more] |
MBE2017-74 pp.41-46 |
CQ |
2017-07-27 13:25 |
Hyogo |
Kobe University |
A Method of Information Presentation Varying Adaptively Depending on the User's Kansei in a Tour-Navigation System
-- An Example of a Koyasan Navigation System -- Masayuki Mori (KIT), Yu Hasegawa (Kindai Univ.), Kazuhiko Morimoto (Koyasan Univ.), Keiji Fujiyoshi (Otemon Gakuin Univ.), Shoichi Takeda (Koyasan Univ.), Shogo Kiryu (TCU) CQ2017-36 |
In a tour-navigation system, authors are conducting research on a method of presenting information that varies adaptivel... [more] |
CQ2017-36 pp.43-48 |
PRMU, IPSJ-CVIM, MVE [detail] |
2017-01-19 18:35 |
Kyoto |
|
Reliability Evaluation of R-R Interval Measurement Status using the Electric Potential Characteristics of QRS Complex for Wearable ECG Devices Kana Eguchi, Ryosuke Aoki, Kazuhiro Yoshida, Tomohiro Yamada (NTT) PRMU2016-140 MVE2016-31 |
Electrocardiogram (ECG) captured by wearable ECG devices easily contains artifact because of the measurement faults. Sin... [more] |
PRMU2016-140 MVE2016-31 pp.171-176 |
ASN, MoNA, MICT (Joint) |
2017-01-20 10:55 |
Oita |
|
A Study on a Practical Heatstroke Prevention Using Wrist-worn Devices Takashi Hamatani, Akira Uchiyama, Teruo Higashino (Osaka Univ.) MoNA2016-37 |
In this paper, we propose a novel application for preventing heatstroke.
The application estimates subject's core tempe... [more] |
MoNA2016-37 pp.35-40 |
HCGSYMPO (2nd) |
2016-12-07 - 2016-12-09 |
Kochi |
Kochi City Culture Plaza (CUL-PORT) |
Wearable Device for Augmented Face-to-Face Behavior: Measurement via Infrared Communication Taku Hachisu, Yadong Pan, Soichiro Matsuda, Baptiste Bourreau, Kenji Suzuki (Univ. Tsukuba) |
This research aims to quantitatively measure and facilitate face-to-face behavior in activities of daily living using we... [more] |
|
IT, EMM |
2016-05-19 15:35 |
Hokkaido |
Otaru Economic Center |
Multimodal User Authentication Focusing on Long-term Heart Rate Sequences from Wearable Devices Takaaki Yoshida (Osaka Univ.), Kazuhiro Kono (Kansai Univ.), Babaguchi Noboru (Osaka Univ.) IT2016-9 EMM2016-9 |
This paper proposes a multimodal authentication system for smartphones
by using two sequences of different measurement ... [more] |
IT2016-9 EMM2016-9 pp.49-54 |
LOIS |
2015-03-06 15:00 |
Okinawa |
|
The Posture Detection Method Using Acceleration Gyro Sensor Fumi Kawasaki, Erina Kitagawa, Naoko Ito, Ami Otsuka, Aoi Yoshida, Tatsuya Aoyagi (Tsuda College) LOIS2014-90 |
In recent years, in addition to the application that support the weight and diet, services that support the health state... [more] |
LOIS2014-90 pp.169-172 |