EMD |
2024-03-01 14:40 |
Chiba |
|
Effects of inductance and surrounding gas on DC break arc discharge Shion Ozaki, Kiyoshi Yoshida (NIT) EMD2023-43 |
The effects of resistive load and inductance on arc discharge during DC power cut-off were investigated. A small electro... [more] |
EMD2023-43 pp.25-29 |
MICT, WBS, RCC, SAT (Joint) [detail] |
2023-05-26 09:25 |
Tokyo |
TOKYO BIG SIGHT (Primary: On-site, Secondary: Online) |
A study on the rain attenuation duration characteristics using the different Ku-band satellite signals measured at multiple locations Yasuyuki Maekawa (Osaka Electro-Commun. Univ.), Koichi Harada, Junichi Abe, Fumihiro Yamashita (NTT Corporation) SAT2023-5 MICT2023-5 |
The signal levels of Ku-band BS broadcast radio waves and JCSAT-5A beacon radio waves have been simultaneously measured ... [more] |
SAT2023-5 MICT2023-5 pp.20-25 |
EMD |
2023-03-03 17:25 |
Saitama |
NIT and Online (Primary: On-site, Secondary: Online) |
Effects of brush force of the commutator motor on brush wear and arc properties Takuma Hirabayashi, Shogo Suzuki, Shoma Matsuura, Koichiro Sawa, Takahiro Ueno (NIT) EMD2022-35 |
In recent years, the automotive industry has seen an increase in the electrification of vehicles, and at the same time, ... [more] |
EMD2022-35 pp.82-87 |
WBS, RCC, SAT, MICT (Joint) [detail] |
2021-05-21 13:25 |
Online |
Online (Zoom) |
Relationship between cumulative time percentages and equivalent path lengths of rain attenuation in Ku-band satellite communication links Yasuyuki Maekawa (Osaka Electro-Commun. Univ.) WBS2021-19 RCC2021-19 SAT2021-17 |
The long-term rain attenuation statistics of cumulative time percentages are obtained from Ku band satellite signal obse... [more] |
WBS2021-19 RCC2021-19 SAT2021-17 pp.101-106(WBS), pp.101-106(RCC), pp.89-94(SAT) |
EMD |
2020-03-06 16:20 |
Chiba |
CHIBA Institute of Technology Tsudanuma Campus (Cancelled but technical report was issued) |
Influence on Various Characteristics with and without Magnet in DC Electromagnetic Contactor Akira Iwanami, Koichiro Sawa, Kiyoshi Yoshida (NIT) EMD2019-70 |
An experiment was conducted on a DC electromagnetic contactor with a structure in which the arc was blown out by the mag... [more] |
EMD2019-70 pp.57-60 |
EMD |
2020-03-06 16:35 |
Chiba |
CHIBA Institute of Technology Tsudanuma Campus (Cancelled but technical report was issued) |
Influence of Magnetic Flux Density and Breaking Speed on Magnetic Blowout of DC Arc Discharge Hiroki Yamauchi, Hayato Watanabe, Koichiro Sawa, Kiyoshi Yoshida (NIT) EMD2019-71 |
The arc duration time ta and the arc energy Ea when a magnetic flux was applied to the electrical contact were measured.... [more] |
EMD2019-71 pp.61-64 |
EMD |
2020-03-06 16:50 |
Chiba |
CHIBA Institute of Technology Tsudanuma Campus (Cancelled but technical report was issued) |
Influence of Ambient Gas on Breaking Arc Discharge of Electromagnetic contactor
-- Effect of Gas Pressure and Current -- Sota Nagase, Yoshiki Yamamoto, Koichiro Sawa, Kiyoshi Yoshida (NIT) EMD2019-72 |
The electromagnetic contactor was opened and closed in air or in hydrogen. The arc duration ta, arc energy Ea, arc exti... [more] |
EMD2019-72 pp.65-70 |
EMD |
2020-01-17 14:55 |
Kanagawa |
Rental hall Shonan Hiratsuka |
Influence of Ambient Gas and Pressure on Break Arc Characteristics in Alternating Current Yoshiki Yamamoto, Sota Nagase, Kiyoshi Yoshida, Koichiro Sawa (NIT), Kenji Suzuki (Fuji Electric FA Components & System) EMD2019-50 |
Arc discharge at break was generated in the electromagnetic contactor in the air and hydrogen. The arc duration ta, the ... [more] |
EMD2019-50 pp.11-16 |
NC, MBE |
2019-12-06 11:25 |
Aichi |
Toyohashi Tech |
Mathematical Model for Generating Human Foot-Lifting Movements onto One-Up Stair-Step from Stair Rise Toshikazu Matsui, Shu Kitabatake (Gunma Univ) MBE2019-49 NC2019-40 |
This research formulates a mathematical model generating foot-lifting movements from only the step rise without any info... [more] |
MBE2019-49 NC2019-40 pp.25-30 |
EMD |
2019-05-17 15:50 |
Miyagi |
Cyberscience Center, Tohoku University |
Influence of ambient gas on arc duration and energy of electromagnetic contactor in AC power supply Kiyoshi Yoshida, Koichiro Sawa (NIT), Kenji Suzuki (Fuji Electric FA Components & Systems) EMD2019-6 |
Arc discharge at break was generated in the electromagnetic contactor in the air and hydrogen. The arc duration ta, the ... [more] |
EMD2019-6 pp.29-34 |
EMD |
2019-03-01 14:15 |
Tokyo |
|
Influence of ambient gas on various characteristics of break arc for electromagnetic contactor with AC power supply Igarashi Takahiro, Kumagai Fuuma, Kiyoshi Yoshida, Koichiro Sawa (NIT) EMD2018-68 |
Arc discharge at break was generated in the electromagnetic contactor in the atmosphere and hydrogen. The arc duration t... [more] |
EMD2018-68 pp.47-52 |
EMD |
2019-03-01 14:45 |
Tokyo |
|
Influence of current and magnetic flux density on magnetic blow-out on arc discharge at breaking of electrical contacts Mano Kenta, Koichiro Sawa, KIyoshi Yoshida (NIT) EMD2018-69 |
Recently, applications using DC high voltage are increasing. In the DC circuit, there is a method called "magnetic blow-... [more] |
EMD2018-69 pp.53-57 |
EMD |
2019-03-01 15:00 |
Tokyo |
|
Influence on various characteristics such as arc duration during continuous make/break of electromagnetic contactor Hiroki Takeuchi, Koichiro Sawa, Kiyoshi Yoshida (NIT) EMD2018-70 |
By forming the contact portion in an airtight structure, it is possible to suppress the ejection of the arc discharge to... [more] |
EMD2018-70 pp.59-62 |
EMD |
2018-05-18 13:30 |
Hokkaido |
Muroran Institute of Technology |
Influence of Magnetic Flux Density and Breaking Velocity and Source Voltage on Magnetic Blow-out Behavior of DC High Voltage Arc Kiyoshi Yoshida, Koichiro Sawa (NIT), Kenji Suzuki (Fuji Electric FA Components & Systems) EMD2018-2 |
Recently, the applications for make and break DC power supply circuits such as solar power generation and electric vehic... [more] |
EMD2018-2 pp.7-12 |
EMD |
2018-03-02 13:35 |
Saitama |
Nippon Institute of Technology |
Influence of Magnetic Flux Density on Blow-out Behavior of DC High Voltage Arc Tsubasa Umezawa, Toshiya Morita, Koichiro Sawa, Kiyoshi Yoshida (NIT) EMD2017-59 |
Solar power generation and electric vehicles (EV) that use high current with high DC voltage are increasing. The role o... [more] |
EMD2017-59 pp.9-12 |
EMD |
2017-11-17 11:10 |
Tokyo |
The University of Electro-Communications |
Effect of arc discharge types on various characteristics and mass change in electrodes for electromagnetic contractor Kiyoshi Yoshida, Koichiro Sawa (Nippon Inst. of Tech.), Kenji Suzuki, Koetsu Takaya (Fuji Electric FA) EMD2017-45 |
Experiments were carried out at several voltages to clarify the influence of the voltage on various characteristics, i.e... [more] |
EMD2017-45 pp.13-19 |
IBISML |
2017-11-09 13:00 |
Tokyo |
Univ. of Tokyo |
Hidden Semi-Markov Model Representing State Overlap for Multiple Sequential Data Input Hiromi Narimatsu, Hiroyuki Kasai (UEC) IBISML2017-49 |
This paper proposes an extended hidden semi-Markov model (HSMM) to handle multiple sequence inputs. The significant limi... [more] |
IBISML2017-49 pp.109-114 |
ICTSSL |
2017-05-30 14:25 |
Miyagi |
NEXCO EAST TOHOKU |
Effect of congestion control schedule on voluntary reduction of call duration Daisuke Satoh, Takemi Mochida, Masayuki Tsujino (NTT) ICTSSL2017-14 |
A control against disaster congestion has been proposed. It permits making a call only in a certain period assigned for ... [more] |
ICTSSL2017-14 pp.69-74 |
EMD |
2017-03-03 13:20 |
Chiba |
|
Influence of Contact Materials and Opening velocity in DC High Voltage Arc Keisuke Kojima, Hidekazu Hirasawa, Koichiro Sawa, Kiyoshi Yoshida (NIT) EMD2016-100 |
Recently, applications using DC high voltage and large current such as photovoltaic power generation and electric vehicl... [more] |
EMD2016-100 pp.5-8 |
EMD |
2017-03-03 13:35 |
Chiba |
|
Influence of Sealed Gas and Pressure on Arc Duration of Electromagnetic Contactor Ryosuke Takei, Masaki Yuzawa, Kiyoshi Yoshida, Koichiro Sawa (NIT) EMD2016-101 |
The electromagnetic contactor was installed in the chamber sealed with nitrogen, hydrogen, helium and clean air, and bre... [more] |
EMD2016-101 pp.9-12 |