EMD 2021-03-08
16:35
Online Online Effect of Contact Oil on Contact Resistance and Friction
Hiroki Ikezaki, Yusuke Aoki, Kazuo Iida (Mie Univ) EMD2020-38
Currently, it is necessary to decrease the insertion force to the automobile connector. Contact oil is one of the means ... [more] EMD2020-38
pp.44-49
EST 2021-01-22
11:00
Online Online Computation of the Local SAR and Temperature Rise in Anatomically-based Hand Model due to Contact Current
Taiki Murakawa, Yinliang Diao, Essam Rashed (NITech), Yoshitsugu Kamimura (Utsunomiya Univ.), Akimasa Hirata (NITech) EST2020-69
Contact current occurs when the human body contacts with an object at a different electric potential. A electrostimulati... [more] EST2020-69
pp.85-90
EMD 2020-12-04
13:05
Online Online Observation of arc discharges occurring between commutator and brush Simulating a DC motor by means of a high-speed camera
Ryosuke Sano, Junya Sekikawa (Shizuoka Univ.) EMD2020-18
Observed results of arc discharges generated between the brush and commutator are reported during arc duration. The arcs... [more] EMD2020-18
pp.1-6
EMD 2020-07-17
15:00
Hokkaido Chitose-Arcadia-Plaza Production of automatic measurement system for contact resistance and its measurement results -- Contact resistance when switching 1 million times under small load condition --
Kiyoshi Yoshida, Koichiro Sawa (NIT), Kenji Suzuki (Fuji FA Comp. & Sys.) EMD2020-6
In this study, we constructed an automatic measurement system for the contact resistance of electrical contacts. This sy... [more] EMD2020-6
pp.17-22
EMT, MW, OPE, EST, MWP, THz, IEE-EMT [detail] 2020-07-16
13:50
Online Online Numerical Investigation of Induced Field in Anatomically-based Hand Model for Contact Current at Intermediate Frequencies
Taiki Murakawa, Yinliang Diao, Essam Rashed, Yoshihiro Tanaka (NITech), Shin Kitamura, Shintaro Uehara, Yohei Otaka (Fujita Health Univ.), Akimasa Hirata (NITech) EMT2020-11 MW2020-20 OPE2020-6 EST2020-11 MWP2020-11
Contact current occurs when the human body comes into contact with an object at a different electric potential, and biol... [more] EMT2020-11 MW2020-20 OPE2020-6 EST2020-11 MWP2020-11
pp.27-32
EMD 2020-03-06
13:05
Chiba CHIBA Institute of Technology Tsudanuma Campus
(Cancelled but technical report was issued)
Effect of solid lubricant on electric sliding contact mechanism
Syou Ogata, Yuki Kawasima, Tatsuro Iizuka, Yoshitada Watanabe, Koichro Sawa, Takahiro Ueno (NIT) EMD2019-59
The electric sliding contact mechanism is a mechanism for energizing while sliding an object such as a pantograph of an ... [more] EMD2019-59
pp.1-4
EMD 2020-03-06
16:05
Chiba CHIBA Institute of Technology Tsudanuma Campus
(Cancelled but technical report was issued)
Production of Automatic Contact Resistance Measurement System for Electrical Contacts
Tatsuya Onodera, Sho Kashiwabara, Koichiro Sawa, Kiyoshi Yoshida (NIT) EMD2019-69
In this study, we constructed an automatic measurement system for the contact resistance of electrical contacts. This sy... [more] EMD2019-69
pp.51-56
EMD 2020-03-06
16:20
Chiba CHIBA Institute of Technology Tsudanuma Campus
(Cancelled but technical report was issued)
Influence on Various Characteristics with and without Magnet in DC Electromagnetic Contactor
Akira Iwanami, Koichiro Sawa, Kiyoshi Yoshida (NIT) EMD2019-70
An experiment was conducted on a DC electromagnetic contactor with a structure in which the arc was blown out by the mag... [more] EMD2019-70
pp.57-60
EMD 2020-03-06
16:35
Chiba CHIBA Institute of Technology Tsudanuma Campus
(Cancelled but technical report was issued)
Influence of Magnetic Flux Density and Breaking Speed on Magnetic Blowout of DC Arc Discharge
Hiroki Yamauchi, Hayato Watanabe, Koichiro Sawa, Kiyoshi Yoshida (NIT) EMD2019-71
The arc duration time ta and the arc energy Ea when a magnetic flux was applied to the electrical contact were measured.... [more] EMD2019-71
pp.61-64
EMD 2020-03-06
16:50
Chiba CHIBA Institute of Technology Tsudanuma Campus
(Cancelled but technical report was issued)
Influence of Ambient Gas on Breaking Arc Discharge of Electromagnetic contactor -- Effect of Gas Pressure and Current --
Sota Nagase, Yoshiki Yamamoto, Koichiro Sawa, Kiyoshi Yoshida (NIT) EMD2019-72
The electromagnetic contactor was opened and closed in air or in hydrogen. The arc duration ta, arc energy Ea, arc exti... [more] EMD2019-72
pp.65-70
SeMI, IPSJ-MBL, IPSJ-UBI 2020-03-03
09:50
Online Online The study of detections of pulse and blood pressure employing quasi-millimeter wave
Yukino Yamaoka, Shigeru Shimamoto, Jiang Liu (Waseda Univ.) SeMI2019-133
High blood pressure has a great impact on the health and welfare of the people since it is a disease with poor subjectiv... [more] SeMI2019-133
pp.179-184
EST 2020-01-30
14:25
Oita Beppu International Convention Center Numerical investigation of hand impedance for contact current evaluation
Taiki Murakawa, Yinliang Diao (NITech), Yoshitsugu Kamimura (Utsunomiya Univ.), Akimasa Hirata (NITech) EST2019-86
Contact current occurs when the human body comes into contact with an object at a different electric potential, and biol... [more] EST2019-86
pp.41-44
EMD 2020-01-17
14:30
Kanagawa Rental hall Shonan Hiratsuka Sliding characteristics of copper contacts by Molybdenum disulfide shot testment
Tatsuro Iizuka, Yuki Kawashima, Syo Ogata, Yoshitada Watanabe, Takahiro Ueno, Koichiro Sawa (NIT) EMD2019-49
The electric sliding contact mechanism is a mechanism for energizing a moving object from a stationary object.
It is us... [more]
EMD2019-49
pp.7-10
EMD 2020-01-17
14:55
Kanagawa Rental hall Shonan Hiratsuka Influence of Ambient Gas and Pressure on Break Arc Characteristics in Alternating Current
Yoshiki Yamamoto, Sota Nagase, Kiyoshi Yoshida, Koichiro Sawa (NIT), Kenji Suzuki (Fuji Electric FA Components & System) EMD2019-50
Arc discharge at break was generated in the electromagnetic contactor in the air and hydrogen. The arc duration ta, the ... [more] EMD2019-50
pp.11-16
EMD 2020-01-17
15:35
Kanagawa Rental hall Shonan Hiratsuka Arc movement observation of DC inductive break arcs of AgSnO2 contacts up to 20V-17A under external magnetic field application
Makoto Hasegawa, Seika Tokumitsu (Chitose Inst. of Sci.&Tech.) EMD2019-51
AgSnO2 contacts were operated to break an inductive DC load circuit of 14V-7A, 14V-12A, 20V-7A, or 20V-17A with an appli... [more] EMD2019-51
pp.17-21
EMD 2019-12-13
14:35
Tokyo   Dependence of arc length just before arc extinction on magnetic flux density when break arcs are blown-out in a 48VDC/50A-200A resistive circuit
Kenshi Hamamoto, Junya Sekikawa (Shizuoka Univ.) EMD2019-43
Break arcs were generated in a 48VDC resistive circuit and blown-out by transverse magnetic field. Circuit current when ... [more] EMD2019-43
pp.1-6
EMD 2019-12-13
16:30
Tokyo   Arc energy calculation in re-striking phenomena in break operations of AgSnO2 contacts in inductive DC load conditions up to 20V-17A
Makoto Hasegawa, Seika Tokumitsu (Chitose Inst. of Sci.&Tech.) EMD2019-47
AgSnO2 contacts were operated to break an inductive DC load circuit of 14V-7A, 14V-12A, 20V-7A, or 20V-17A with an appli... [more] EMD2019-47
pp.25-30
EMD 2019-05-17
15:50
Miyagi Cyberscience Center, Tohoku University Influence of ambient gas on arc duration and energy of electromagnetic contactor in AC power supply
Kiyoshi Yoshida, Koichiro Sawa (NIT), Kenji Suzuki (Fuji Electric FA Components & Systems) EMD2019-6
Arc discharge at break was generated in the electromagnetic contactor in the air and hydrogen. The arc duration ta, the ... [more] EMD2019-6
pp.29-34
EA, SIP, SP 2019-03-15
10:25
Nagasaki i+Land nagasaki (Nagasaki-shi) Neural Language Models based on Conditional Hierarchical Recurrent Encoder-Decoder for Multi-Party Conversational Speech Recognition
Ryo Masumura, Tomohiro Tanaka, Atsushi Ando, Takanobu Oba, Yushi Aono (NTT) EA2018-131 SIP2018-137 SP2018-93
This paper presents fully neural network based language models (LMs) that can leverage long-range conversational context... [more] EA2018-131 SIP2018-137 SP2018-93
pp.191-196
EMD 2019-03-01
10:35
Tokyo   A study in influences of external magnetic field on break arc characteristics of AgSnO2 contacts in a DC inductive load circuit up to 20V-17A up to 20V-17A
Seika Tokumitsu, Makoto Hasegawa (Chitose Inst. of Science & Technology) EMD2018-59
For the purpose of investigating influences of application of an external magnetic field on shortenings of break arc dur... [more] EMD2018-59
pp.1-6
 Results 21 - 40 of 300 [Previous]  /  [Next]  
Choose a download format for default settings. [NEW !!]
Text format pLaTeX format CSV format BibTeX format
Copyright and reproduction : All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034)


[Return to Top Page]

[Return to IEICE Web Page]


The Institute of Electronics, Information and Communication Engineers (IEICE), Japan