IEICE Technical Committee Submission System
Conference Schedule
Online Proceedings
[Sign in]
Tech. Rep. Archives
    [Japanese] / [English] 
( Committee/Place/Topics  ) --Press->
 
( Paper Keywords:  /  Column:Title Auth. Affi. Abst. Keyword ) --Press->

All Technical Committee Conferences  (Searched in: All Years)

Search Results: Conference Papers
 Conference Papers (Available on Advance Programs)  (Sort by: Date Descending)
 Results 21 - 40 of 159 [Previous]  /  [Next]  
Committee Date Time Place Paper Title / Authors Abstract Paper #
SP, IPSJ-SLP, IPSJ-MUS 2021-06-19
15:00
Online Online Simulation of Body-conducted Speech and Synthesis of One's Own Voice with a Sound-proof Earmuff and Bone-conduction Microphones
Chen Ruiyan, Nishimura Tazuko, Minematsu Nobuaki, Saito Daisuke (UTokyo) SP2021-15
When one hears his/her recorded voices for the first time, s/he is probably surprised and not rarely disappointed at the... [more] SP2021-15
pp.63-68
MI 2021-03-15
11:00
Online Online Improvement of a skeletal recognition algorithm of bone scintigrams
Yuri Hoshino, Atsushi Saito (TUAT), Atsushi Yoshida, Shigeaki Higashiyama, Joji Kwabe (Osaka City Univ), Hiromitsu Daisaki (GCHS), Kazuhiro Nishikawa (NMP), Akinobu Shimizu (TUAT) MI2020-47
In this paper, we report the results of our work on skeletal recognition processing on bone scintigram. Specifically, we... [more] MI2020-47
pp.1-2
EA, US, SP, SIP, IPSJ-SLP [detail] 2021-03-03
14:05
Online Online [Poster Presentation] The effect of periosteitis on the wave velocity in the third metatarsal bone -- Comparison with healthy bone --
Sota Tanizawa, Kazuki Miyashita, Mineaki Takada (Doshisha Univ.), Norihisa Tamura, Hiroshi Mita (JRA), Mami Matsukawa (Doshisha Univ.) US2020-79
Using an ultrasonic pulse method, we evaluated wave propagation characteristics (velocity and attenunation) in the corti... [more] US2020-79
pp.13-17
US 2021-01-29
13:50
Online Online Development of Axial Transmission technique for the evaluation of equine metacarpal bone
Kazuki Miyashita, Takashi Misaki, Mineaki Takata (Doshisha Univ.), Ko Chiba (Nagasaki Univ.), Hiroshi Mita, Norihisa Tamura (JRA), Mami Matsukawa (Doshisha Univ.) US2020-58
Evaluation of bone inflammation is very important for racehorses. The present mainstream of bone evaluation is X-ray tec... [more] US2020-58
pp.3-8
EA 2020-12-14
10:05
Online Online Speech Signal Detection Based on Bayesian Estimation by Observing Air-Conducted Speech under Existence of Surrounding Noise with Aid of Bone-Conducted Speech
Akira Ikuta, Hisako Orimoto (Prefectural Univ. of Hiroshima), Kouji Hasegawa (Hiroshima Prefectural Technology Research Inst.) EA2020-48
When applying speech recognition systems to actual circumstances such as inspection and maintenance operations in indust... [more] EA2020-48
pp.13-18
EA, ASJ-H, EMM 2020-11-20
13:30
Online Online [Poster Presentation] Study of the mixing ratio of anti-noise dual microphone
Hiryu Matsumoto, Masaharu Kori, Shinya Shamoto, Shigeaki Aoki, Suehiro Shimauchi (KIT) EA2020-35 EMM2020-50
We have been studying a dual microphone system that achieves both noise resistance and high sound quality by combining a... [more] EA2020-35 EMM2020-50
pp.74-77
US 2020-07-31
15:20
Online Online Evaluation of periosteitis in equine cortical bone by ultrasonic method
Mineaki Takata (Doshisha Ubiv.), Norihisa Tamura, Hiroshi Mita (JRA), Tsukasa Nakamura, Kazuki Miyashita, Mami Matsukawa (Doshisha Ubiv.) US2020-18
Using an ultrasonic pulse method, we evaluated the distribution of longitudinal wave velocity in the cortical bone of th... [more] US2020-18
pp.27-31
SC 2020-05-29
13:30
Online Online Characterizing Quality of In-home Physical Activities Using Bone-based Human Sensing
Sinan Chen, Sachio Saiki, Masahide Nakamura (Kobe Univ.) SC2020-1
In recent years, with the conversion to home care in the aging society, it is significant for extending healthy life spa... [more] SC2020-1
pp.1-6
SP, EA, SIP 2020-03-03
16:15
Okinawa Okinawa Industry Support Center
(Cancelled but technical report was issued)
A Portscan Detection Based on Low-rankness of Destination Port Matrices
Hiroki Nousou, Masao Yamagishi, Isao Yamada (Tokyo Tech) EA2019-167 SIP2019-169 SP2019-116
The detection of port scans as possible preliminaries to more serious attacks is important for system administrators and... [more] EA2019-167 SIP2019-169 SP2019-116
pp.385-390
US 2020-02-28
17:00
Tokyo   Measurement of air conduction sound in the ear canal during tooth excitation and consideration of tooth excitation position
Mikio Mori, Yusuke Muraki, Yoshihisa Torii, Kenichi Tanide, Mitsuhiro Ogihara (Fukui Univ.) US2019-106
We propose an implanted hearing aid that is worn in the crown of a dental implant and uses the mechanism of bone conduct... [more] US2019-106
pp.41-46
MI 2020-01-30
13:25
Okinawa OKINAWAKEN SEINENKAIKAN MI2019-114 (To be available after the conference date) [more] MI2019-114
pp.207-208
EA, US
(Joint)
2020-01-22
14:00
Kyoto Doshisha Univ. [Poster Presentation] Effects of Ultrasound propagation in skull bone on Transcranial Doppler method -- Simulation using FDTD method --
Kota Kitamura (Doshisha Univ.), Kozue Saito (Nara Med. Univ./NCVC), Masaya Saeki, Itsuki Michimoto, Mami Matsukawa (Doshisha Univ.) US2019-89
Recently, Transcranial Doppler method (TCD) is used for the evaluation of blood flow and the detection of emboli in the ... [more] US2019-89
pp.103-106
EA, EMM 2019-11-22
14:00
Ishikawa Kanazawa Institute of Technology [Poster Presentation] Study of the synthetic condition of anti-noise dual microphone
Hiryu Matsumoto, Wataru Anami, Shigeaki Aoki, Suehiro Shimauchi (KIT) EA2019-50 EMM2019-78
To make it easy to talk in a noisy environment using a communication terminal such as a mobile phone, a dual microphone ... [more] EA2019-50 EMM2019-78
pp.1-4
US 2019-11-11
13:50
Shizuoka   Laser ultrasound study on the longitudinal wave velocity changes in cortical bone due to abnormal collagen cross-links
Masaki Kuraoka, Tsukasa Nakamura, Takumi Fukunaga, Hirokazu Yasui, Mami Matsukawa (Doshisha Univ.) US2019-59
The decrease of bone strength is one of the factors of bone fracture risk. Diabetic patients have higher bone fracture r... [more] US2019-59
pp.11-15
SCE 2019-10-09
15:50
Miyagi   Evaluation of fishbone-type superconducting resonator
Kohki Nakagawa (Shizuoka Univ.), Atsushi Saito (Yamagata Univ.), Hirotaka Terai (NICT), Masanori Takeda (Shizuoka Univ.) SCE2019-25
Fishbone transmission line (FTTL) is an artificial transmission line with a periodic structure. FTTL can produce a trans... [more] SCE2019-25
pp.17-21
PRMU, MI, IPSJ-CVIM [detail] 2019-09-04
15:40
Okayama   Preliminary investigation on decomposition of individual muscles and bones of lower extremity from single radiograph using CycleGAN
Naoki Nakanishi, Yuta Hiasa, Yoshito Otake (NAIST), Masaki Takao, Nobuhiko Sugano (Osaka Univ.), Yoshinobu Sato (NAIST) PRMU2019-16 MI2019-35
Extraction of musculoskeletal structures of lower extremity from medical images is useful for quantitatively understandi... [more] PRMU2019-16 MI2019-35
pp.25-30
MI 2019-07-06
11:30
Hokkaido Future Univ. Hakodate Improvement of tracking of hyoid bones in videofluorography by use of SVM
Shunpei Yaita, Ayano Fujinaka (Univ. of Tsukuba), Kojiro Mekata (KRCH), Hotaka Takizawa, Hiroyuki Kudo (Univ. of Tsukuba) MI2019-29
In this report, we proposed the improved method of tracking of hyoid bones in videofluorography (VF). First, the candida... [more] MI2019-29
pp.41-42
US 2019-05-20
13:00
Tokyo   Site dependence of ultrasonically induced electrical potentials in bone
Tsukasa Nakamura, Taiki Makino, Mineaki Takata, Takumi Fukunaga, Mami Matsukawa (Doshisha Univ.) US2019-8
Many clinical results on low intensity pulsed ultrasound (LIPUS) therapy have been reported, including the success rate ... [more] US2019-8
pp.1-5
EA, US
(Joint)
2019-01-22
10:30
Kyoto Doshisha Univ. [Poster Presentation] The effect of diabetes on longitudinal wave velocity in bone
Hirokazu Yasui, Yuki Kuzuhara, Takumi Fukunaga, Yuki Harada, Hiromichi Hayachi, Ikegawa Masaya, Mami Matsukawa (Doshisha Univ.) US2018-90
The decrease of bone strength is one of the factors of bone fracture risk. Diabetic patients have higher bone fracture r... [more] US2018-90
pp.55-59
SSS 2018-09-25
16:25
Tokyo   Listening examination of subject's voice in MRI operation room of noisy environment
Michi Inagaki, Kenji Muto (Shibaura Inst Tech.) SSS2018-24
In general, bone conduction microphone measuring vibration acceleration is effective for noise. MRI devices are medical ... [more] SSS2018-24
pp.21-24
 Results 21 - 40 of 159 [Previous]  /  [Next]  
Choose a download format for default settings. [NEW !!]
Text format pLaTeX format CSV format BibTeX format
Copyright and reproduction : All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034)


[Return to Top Page]

[Return to IEICE Web Page]


The Institute of Electronics, Information and Communication Engineers (IEICE), Japan