|
|
All Technical Committee Conferences (Searched in: All Years)
|
|
Search Results: Conference Papers |
Conference Papers (Available on Advance Programs) (Sort by: Date Descending) |
|
Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
MBE |
2008-05-23 14:15 |
Toyama |
Faculty of Engineering, Toyama University |
A semiautomatic method for extracting born contour from fluoroscopic image of the knee Koji Oda, Toyohiko Hayashi, Yasuo Nakamura, Go Omori (Niigata Univ.) MBE2008-8 |
In order to analyze knee motion after total knee arthroplasty (TKA), a 3-D model-based technique was developed by combin... [more] |
MBE2008-8 pp.33-38 |
CS, SIP, CAS |
2008-03-06 12:55 |
Yamaguchi |
Yamaguchi University |
Blind Super-Resolution Based on Simultaneous Registration and Reconstruction Osama A. Omer, Toshihisa Tanaka (Tokyo Univ. of Agriculture and Tech.) CAS2007-117 SIP2007-192 CS2007-82 |
Super-resolution is an approach to obtain high-resolution (HR) image(s)
from a set of low-resolution images. HR image r... [more] |
CAS2007-117 SIP2007-192 CS2007-82 pp.51-56 |
CS, SIP, CAS |
2008-03-06 13:45 |
Yamaguchi |
Yamaguchi University |
Blind Super Resolution for Moving Object Image with Motion Blur Ryoichi Sakuragi, Nozomu Hamada (Keio Univ.) CAS2007-119 SIP2007-194 CS2007-84 |
In this paper, we propose a blind super resolution method for moving object image with motion blur. The proposed method ... [more] |
CAS2007-119 SIP2007-194 CS2007-84 pp.63-68 |
ICD, ITE-IST |
2006-07-28 16:10 |
Shizuoka |
|
Wide-dynamic-range image sensor with suppressing motion blur Akihiro Hara, Kentaro Masuda, Takayuki Hamamoto (Tokyo University of Science) |
We propose new smart image sensor on which the integration time of each pixel is adapted by using the functions of satur... [more] |
ICD2006-77 pp.97-100 |
PRMU |
2006-03-17 11:15 |
Fukuoka |
Kyushu Univ. |
Kenichi Yoneji, Masayuki Tanaka, Masatoshi Okutomi (Tokyo Inst. of Tech.) |
Images are blurred by camera shakes or moving objects.
When the PSF(Point Spread Function) which is a degradation funct... [more] |
PRMU2005-275 pp.107-114 |
PRMU, TL |
2006-02-24 10:00 |
Ibaraki |
|
Restoring Motion-blur using complex-sinusoidally modulated imaging Dabi Wei, Toru Kurihara, Shigeru Ando (Tokyo Univ.) |
In this report, we study about restoring motion-blur by complex sinusoidally modulated imaging with the Correlation Imag... [more] |
TL2005-75 PRMU2005-210 pp.49-54 |
MI |
2005-01-21 11:40 |
Okinawa |
Univ. of the Ryukus |
Non-linear motion correction of respiratory-Gated SPECT image Hidenori Ue, Hideaki Haneishi (Chiba Univ.), Hideyuki Iwanaga, Yona Ooishi, Ryoko Ide, Masahiro Koike, Kazuyoshi Suga (Yamaguchi Univ.) |
Respiratory-gated SPECT is effective for avoiding blur of a reconstructed image which is caused by the respiratory motio... [more] |
MI2004-56 pp.31-36 |
|
|
|
Copyright and reproduction :
All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034)
|
[Return to Top Page]
[Return to IEICE Web Page]
|