Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
MI |
2011-01-20 10:00 |
Okinawa |
Naha-Bunka-Tembusu |
Computerized detection of saccular aneurysms in intracranial three-demensional MRA Hiroaki Tada (Chiba Rosai Hosp./Gifu Univ.), Yoshinori Ozawa (Chiba Rosai Hosp.), Takeshi Hara, Hiroshi Fujita (Gifu Univ.) MI2010-88 |
We propose a method to detect small saccular intracranial aneurysms in three-dimensional MRA. In the proposed method, sh... [more] |
MI2010-88 pp.41-46 |
IPSJ-SLDM, SIP, IE, ICD [detail] |
2010-10-05 13:20 |
Chiba |
Makuhari Messe, International Conference Hall |
Study of stacked NOR type MRAM using spin transistor Shouto Tamai, Shigeyoshi Watanabe (sit) SIP2010-55 ICD2010-69 IE2010-73 |
In this paper stacked NOR type MRAM with vertical spin transistor has been newly proposed. Word line scheme surrounded b... [more] |
SIP2010-55 ICD2010-69 IE2010-73 pp.37-42 |
ICD, SDM |
2010-08-27 11:40 |
Hokkaido |
Sapporo Center for Gender Equality |
Study of stacked MRAM for universal memory Shouto Tamai, Shigeyoshi Watanabe (Shonan Inst. of Tech.) SDM2010-142 ICD2010-57 |
In this paper stacked NOR type MRAM with vertical spin transistor has been newly proposed. Word line scheme surrounded b... [more] |
SDM2010-142 ICD2010-57 pp.99-104 |
MBE |
2010-06-30 15:00 |
Hokkaido |
Hokkaido Univ. |
An implementation of the portable MRA image observation tool on an embedded system Hiroaki Osawa, Masahiko Hatanaka (Muroran Inst. of Tech.) MBE2010-12 |
We have been studying a portable 3D-MRA (Magnetic Resonance Angiography) image data observation tool on Laptop PC. This ... [more] |
MBE2010-12 pp.9-12 |
ICD |
2010-04-22 13:30 |
Kanagawa |
Shonan Institute of Tech. |
[Invited Talk]
A 64Mbit MRAM with Clamped-Reference and Adequate-Reference Schemes Kenji Tsuchida, Tsuneo Inaba, Katsuyuki Fujita, Yoshihiro Ueda, Takafumi Shimizu, Yoshiaki Asao, Takeshi Kajiyama, Masayoshi Iwayama, Sumio Ikegawa, Tatsuya Kishi, Tadashi Kai, Minoru Amano, Naoharu Shimomura, Hiroaki Yoda, Yohji Watanabe (TOSHIBA) ICD2010-7 |
A 64Mb spin-transfer-torque MRAM in 65nm CMOS is developed. 47mm2 die uses 0.3584um2 cell with the perpendicular-TMR dev... [more] |
ICD2010-7 pp.35-40 |
MI |
2010-01-29 09:40 |
Okinawa |
Naha-Bunka-Tenbusu |
The effect of training with simple pointed lesion dataset on classification accuracy
-- Preliminary study for development of CAD software with incremental learning function on clinical application -- Mitsutaka Nemoto, Yukihiro Nomura (Univ. Tokyo Hospital), Yoshitaka Masutani (Univ. Tokyo Hospital/Univ. Tokyo), Shouhei Hanaoka (Univ. Tokyo), Takeharu Yoshikawa, Naoto Hayashi, Naoki Yoshioka (Univ. Tokyo Hospital), Kuni Ohtomo (Univ. Tokyo Hospital/Univ. Tokyo) MI2009-121 |
CAD (Computer Assisted Detection) software in clinical use needs a robustness for image feature variations caused by dif... [more] |
MI2009-121 pp.247-252 |
ICD |
2009-12-14 13:30 |
Shizuoka |
Shizuoka University (Hamamatsu) |
[Poster Presentation]
Design Technology of stacked NAND type MRAM Shouto Tamai, Shigeyoshi Watanabe (Shonan Inst. of Tech.) ICD2009-79 |
Design technology of stacked type MRAM using spin transistor has been described. Using 64 layer level cell structure fea... [more] |
ICD2009-79 pp.19-23 |
IN |
2009-12-10 14:15 |
Hyogo |
KOBE UNIVERSITY |
A Multiple Reader Antenna Method for Position Estimation in Passive RFID Tag system Manato Fujimoto, Toshihiro Hori, Norie Uchitomi, Tomotaka Wada (Kansai Univ.), Kouichi Mutsuura (Shinshu Univ.), Hiromi Okada (Kansai Univ.) IN2009-94 |
Recently, the RFID system is paid attention as an identification source by lot of people. A user identifies an object in... [more] |
IN2009-94 pp.41-46 |
ITE-MMS, MRIS |
2009-10-08 13:55 |
Fukuoka |
FUKUOKA traffic center |
[Invited Talk]
Nonvolatile RAM using spin transfer torque magnetization reversal (SPRAM) Hiromasa Takahashi, Kenchi Ito, Jun Hayakawa, Katsuya Miura, Hiroyuki Yamamoto, Michihiko Yamanouchi (ARL, Hitachi, Ltd.), Kazuo Ono, Riichiro Takemura, Takayuki Kawahara (CRL, Hitachi, Ltd.), Ryutaro Sasaki (RIEC Tohoku Univ.), Haruhiro Hasegawa (RIEC Tohoku Univ., ARL, Hitachi, Ltd.), Shoji Ikeda (RIEC Tohoku Univ.), Hideyuki Matsuoka (ARL, Hitachi, Ltd.), Hideo Ohno (RIEC Tohoku Univ.) |
The SPRAM (Spin Transfer Torque MRAM) is one of nonvolatile memories that “writing” is done by that a magnetization in M... [more] |
|
ITE-MMS, MRIS |
2009-10-09 11:35 |
Fukuoka |
FUKUOKA traffic center |
Stress assisted magnetization reversal of a spin valve structural perpendiculr GMR muti-layer Kazuya Jimbo, Naoya Saito, Shigeki Nakagawa (Tokyo Inst. of Tech.) MR2009-27 |
A Stress Assisted Magnetization Reversal (SAMR) method has been demonstrated in order to reduce a powerconsumption durin... [more] |
MR2009-27 pp.37-40 |
ICD, SDM |
2009-07-17 14:10 |
Tokyo |
Tokyo Institute of Technology |
Low Current Perpendicular Domain Wall Motion Cell for Scalable High-Speed MRAM Shunsuke Fukami, Tetsuhiro Suzuki, Kiyokazu Nagahara, Norikazu Ohshima (NEC Corp.), Yasuaki Ozaki (NECEL Corp.), Shinsaku Saito, Ryusuke Nebashi, Noboru Sakimura, Hiroaki Honjo, Kaoru Mori, Chuji Igarashi, Sadahiko Miura, Nobuyuki Ishiwata, Tadahiko Sugibayashi (NEC Corp.) SDM2009-114 ICD2009-30 |
We have developed a new magnetic random access memory with current-induced domain wall motion (DW-motion MRAM) using per... [more] |
SDM2009-114 ICD2009-30 pp.91-95 |
SDM, ED |
2009-06-24 15:00 |
Overseas |
Haeundae Grand Hotel, Busan, Korea |
Transient characteristic of fabricated Magnetic Tunnel Junction (MTJ) programmed with CMOS circuit Masashi Kamiyanagi, Fumitaka Iga, Shoji Ikeda (Tohoku Univ.), Katsuya Miura (Tohoku Univ./Hitachi), Jun Hayakawa (Hitachi), Haruhiro Hasegawa, Takahiro Hanyu, Hideo Ohno, Tetsuo Endoh (Tohoku Univ.) ED2009-52 SDM2009-47 |
In this paper, it is shown that our fabricated MTJ of 60x180${\rm nm^2}$, which is connected to the MOSFET in series by ... [more] |
ED2009-52 SDM2009-47 pp.9-12 |
SDM, ED |
2009-06-24 15:15 |
Overseas |
Haeundae Grand Hotel, Busan, Korea |
Study of the DC Performance of Fabricated Magnetic Tunnel Junction Integrated on Back-end Metal Line of CMOS Circuits Fumitaka Iga, Masashi Kamiyanagi, Shoji Ikeda (Tohoku Univ.), Katsuya Miura (Tohoku Univ./Hitachi), Jun Hayakawa (Hitachi), Haruhiro Hasegawa, Takahiro Hanyu, Hideo Ohno, Tetsuo Endoh (Tohoku Univ.) ED2009-53 SDM2009-48 |
In this paper, we have succeeded in the fabrication of high performance Magnetic Tunnel Junction (MTJ) which is integrat... [more] |
ED2009-53 SDM2009-48 pp.13-16 |
PRMU, IE, MI |
2009-05-29 10:00 |
Gifu |
Gifu Univ. |
Intracranial aneurysms detection using directional vector of luminance distribution in MRA images Masahito Aoyama, Takuya Kusu, Masayuki Mukunoki, Naoki Asada (Hiroshima City Univ.), Yosuke Komeda, Takashi Okigawa, Joji Urata (Saiseikai Kumamoto Hosp.) IE2009-35 PRMU2009-26 MI2009-26 |
In this paper, we describe a computerized scheme for detection the intracranial unruptured aneurysms
in MRA images. Our... [more] |
IE2009-35 PRMU2009-26 MI2009-26 pp.141-146 |
MBE |
2009-01-24 09:30 |
Saga |
Saga University |
Improvement of automatic cardiac rest period determination for coronary MRA Kazutaka Uneno, Tetsuo Sato (Nara Inst. of Scie and Tech.), Tomohisa Okada (Kyoto Univ. Hosp.), Shigehide Kuhara (Toshiba Medical Systems Co.), Kaori Togashi (Kyoto Univ.), Kotaro Minato (Nara Inst. of Scie and Tech.) MBE2008-84 |
The purpose of this study is to improve an automated method without user interaction for selecting optimal data acquisit... [more] |
MBE2008-84 pp.37-42 |
PRMU |
2008-12-18 14:50 |
Kumamoto |
Kumamoto Univ. |
Proposal of a distant vehicle recognition method using frame-merging applied MRA Yusuke Kanzawa, Takenao Ohkawa (Kobe Univ.), Toshio Ito (Daihatsu Motor Co.,Ltd.) PRMU2008-160 |
Many researchers have proposed methods of recognizing front vehicles by onboard cameras. However, with these recognition... [more] |
PRMU2008-160 pp.75-80 |
MRIS, ITE-MMS |
2008-12-11 16:20 |
Ehime |
Ehime University |
Road map of stress assisted magnetization reversal for perpendicular MRAM Naoya Saito, Shigeki Nakagawa (Tokyo Tech.) MR2008-43 |
MRAM has been regarded as a next generation memory. However, high power consumption arising from writing process is one ... [more] |
MR2008-43 pp.31-36 |
MRIS, ITE-MMS |
2008-12-11 16:50 |
Ehime |
Ehime University |
[Invited Talk]
Excellent scalability of Magnetic Random Access Memory using spin transfer switching and perpendicular magnetic anisotropy Masahiko Nakayama, Tadashi Kai, Hisanori Aikawa, Junichi Ozeki, Katsuya Nishiyama, Toshihiko Nagase, Minoru Amano, Sumio Ikegawa, Tatsuya Kishi, Hiroaki Yoda (Toshiba) MR2008-44 |
Low switching current and Large thermal stability factor is important for achieving a high-density MRAM using spin trans... [more] |
MR2008-44 pp.37-41 |
IE, SIP, IPSJ-SLDM |
2008-10-06 15:20 |
Iwate |
Aiina Center (Morioka) |
A Low-level vessel extraction method in MRA image using MIP images Abulajiang Abudurexiti, Koichi Matsuda (Iwate Pref. Univ.) SIP2008-110 IE2008-74 |
In this paper we present an accurate extraction method of seed points using MIP(maximum intensity projection) image whic... [more] |
SIP2008-110 IE2008-74 pp.17-22 |
MBE |
2008-06-20 13:30 |
Hokkaido |
Graduate School of Information Sci. and Tech., Hokkaido University |
A user interface for MRA rendaring based on the vascular tracking lines Daisuke Umezu, Tunehiko Tadokoro (muroran-it), Satoshi Ohashi (Tomakomai National College of Tech.), Masahiko Hatanaka (muroran-it) MBE2008-14 |
We have developed a portable 3D-MRA (Magnetic Resonance Angiography) image viewing terminal, which is able to create and... [more] |
MBE2008-14 pp.1-4 |