Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
EMCJ, EST |
2014-09-12 10:30 |
Hokkaido |
Kitami Inst. Technology |
Investigation of Position to Install a Capacitor to Power Distribution Network for Suppressing Mode Conversion Toshiki Mikura, Yoshitaka Toyota, Kengo Iokibe (Okayama Univ.) EMCJ2014-32 EST2014-46 |
The discontinuity in multiple transmission line, i.e. the change in cross-sectional structure of the trace causes mode c... [more] |
EMCJ2014-32 EST2014-46 pp.5-10 |
EMCJ |
2013-07-11 15:05 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
Reducing Common-Mode Noise of Power Converter Using Impedance Balance Method. Atsuhiro Takahashi, Hiroshi Tsukada, Takashi Kojima, Yoshiyuki Hattori (TOYOTA Central Labs.), Tsuyoshi Funaki (Osaka Univ.), Osami Wada (Kyoto Univ.) EMCJ2013-35 |
This study discusses the generating mechanism of the common-mode voltage in FM-radio band at the input terminal of a ste... [more] |
EMCJ2013-35 pp.45-50 |
EE, CPM |
2013-01-24 10:50 |
Kumamoto |
|
Suppression of common-mode noise by two three-phase inverters configured symmetrically Shinya Hirakawa, Masahito Shoyama (Kyushu Univ.) EE2012-30 CPM2012-152 |
Nowadays three-phase inverters are used in various fields to drive three-phase motors. However, the inverters generate c... [more] |
EE2012-30 CPM2012-152 pp.13-16 |
EMCJ |
2012-09-07 14:10 |
Hokkaido |
Hkkaido Univ. |
Investigation of the mode conversion from the common-mode to normal-mode on a noise filter in power electronics applications Mamoru Kamikura, Yuichiro Murata, Yasuhiro Shiraki, Akinori Nishizawa (Mitsubishi Electric Corp.) EMCJ2012-57 |
The noise mode conversion from the common-mode to the normal-mode can occur in power electronics applications because of... [more] |
EMCJ2012-57 pp.31-34 |
EMCJ, ITE-BCT |
2011-03-11 14:55 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
Equivalent Circuit Modeling and Optimization for Reduction of Common-Mode Current in Automotive EMC Shingo Okada (Shizuoka Univ.), Takanori Uno (DENSO CORP.), Hideki Asai (Shizuoka Univ.) EMCJ2010-125 |
In this paper, first, we introduce a practical equivalent circuit modeling for the automotive electromagnetic compatibil... [more] |
EMCJ2010-125 pp.39-44 |
EMCJ, ITE-BCT |
2011-03-11 16:00 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
[Invited Talk]
Integrating Ground Resonators with Slot-crossing Differential Signals to Suppress Common-mode Radiation Hao-Hsiang Chuang, Tzong-Lin Wu (National Taiwan Univ.) EMCJ2010-127 |
A novel grounded resonator technique is proposed and both of its mechanism and performance is demonstrated. The proposed... [more] |
EMCJ2010-127 pp.51-52 |
EMCJ |
2009-09-04 11:15 |
Kyoto |
KEIHANNA PLAZA |
Leaked Emissions due to the In-House Broadband Powerline Communications (1)
-- Measurements of the Electric Field Strength at a Distance and Direct Measurements of the Common-Mode Current -- Masatoshi Ohishi (NAOJ), Masahiro Kitagawa, Hiroaki Misawa, Fuminori Tsuchiya (Osaka Uhiv.) EMCJ2009-40 |
Measurements on the leaked electric field, when the in-house broadband power line communication (PLC) devices are in use... [more] |
EMCJ2009-40 pp.29-34 |
EMCJ |
2009-01-23 10:05 |
Fukuoka |
|
[Special Talk]
EMC Technologies in Switching Converters Tamotsu Ninomiya (Nagasaki University) EMCJ2008-102 |
Abstract Recently a lot of switching converters have been used in almost all electronic equipments, and they have been ... [more] |
EMCJ2008-102 pp.1-6 |
EMCJ |
2008-03-07 09:35 |
Tokyo |
Kikai-Shinko-Kaikan Bldg |
Measurements of the Radiated Electric Field and the Common Mode Current from the In-house Broadband Power Line Communications in Residential Environment III Masahiro Kitagawa (Osaka Univ.), Masatoshi Ohishi (NAO) EMCJ2007-117 |
The radiated electric field (REF) of the in-house broadband power line communications (PLC) in Japan is supposed to be b... [more] |
EMCJ2007-117 pp.1-6 |
EMCJ |
2008-01-25 15:00 |
Saga |
Saga University |
A study of the placement of common-mode points in the WBFC method for EM-immunity test Naoki Kagawa (Fukuyama Univ.) EMCJ2007-113 |
To find the optimum measurement condition of the immunity test with the workbench faraday cage (WBFC) method, the author... [more] |
EMCJ2007-113 pp.43-48 |
EMCJ, MW |
2007-10-25 09:35 |
Miyagi |
Tohoku University |
Measurements of the Radiated Electric Field and the Common Mode Current from the In-house Broadband Power Line Communications in Residential Environment II Masahiro Kitagawa (Osaka Univ.), Masatoshi Ohishi (NAO) EMCJ2007-53 MW2007-100 |
Japanese regulations of in-house broadband power line communications (PLC)
are supposed to suppress the radiated electr... [more] |
EMCJ2007-53 MW2007-100 pp.1-6 |
EMCJ |
2007-09-21 11:25 |
Kyoto |
Doshisha University |
Balance Control of Power-supply Interconnection in Printed Circuit Boards and ICs for Reduction of Common-mode Current Flowing on Attached Cables Kenta Mizui, Osami Wada, Umberto Paoletti, Takashi Hisakado (Kyoto Univ.) EMCJ2007-45 |
In this report, the balance control of a simple circuit consisting of a PCB with an IC having one power-supply line and ... [more] |
EMCJ2007-45 pp.13-18 |
EMCJ |
2007-09-21 14:25 |
Kyoto |
Doshisha University |
Measurements of the Radiated Electric Field and the Common Mode Current from the In-house Broadband Power Line Communications in Residential Environment I Masahiro Kitagawa (Osaka Univ.), Masatoshi Ohishi (NAO) EMCJ2007-49 |
In Japan, in-house broadband power line communications (PLC) are regulated only in terms of the common-mode current (CMI... [more] |
EMCJ2007-49 pp.37-42 |
EMCJ |
2006-12-15 13:35 |
Aichi |
Nagoya Institute of Technology |
Technique of Radio Noise Estimation in Vehicle-Mounted Communication Network Youichirou Suzuki, Noboru Maeda (SOKEN), Nobuyuki Iwasaki (DENSO) EMCJ2006-89 |
The EM noise emission in radio band from wire harnesses (radio noise) is evaluated by actual measurement test complying ... [more] |
EMCJ2006-89 pp.47-52 |
EMCJ |
2005-12-09 14:10 |
Gifu |
Gifu University |
Estimation of Common-Mode Current in Vehicle-Mounted LAN Kazuhisa Ishimaru, Noboru Maeda (SOKEN), Takashi Murase, Koji Kondo (DENSO) |
Recently emission noise, induced by common-mode current through vehicle-mounted LAN, has been a lot of risk to make surr... [more] |
EMCJ2005-121 pp.41-44 |
EMCJ, EMD |
2005-07-29 13:55 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
Examination for imbalance matching at receiver terminal in high speed differential transmission system Kazuya Morimitsu, Hiroshi Shigenari, Yoshitaka Toyota, Ryuji Koga (Okayama Univ.), Osami Wada (Kyoto Univ.) |
In differential signaling,the circuit configuration must be symmetric. If its configuration is asymmetric,common-mode cu... [more] |
EMCJ2005-54 EMD2005-33 pp.7-12 |
EE |
2005-02-09 14:10 |
Fukuoka |
|
Optimum Design Considerations of Balanced Boost Switching Converter to Reduce Common-Mode Conducted Noise Tetsushi Tsumura, Masahito Shoyama, Tamotsu Ninomiya (Kyushu Univ.) |
Because conventional switching converters are usually using unbalanced circuit topologies, parasitic capacitance between... [more] |
EE2004-75 pp.57-62 |