Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
HIP |
2020-10-09 14:35 |
Online |
Online |
A new calibration method for gaze estimation by a camera installed almost by the side of the eye Keisuke Kawamoto, Atsumu Naito, Kiyoshi Hoshino (Univ.Tsukuba) HIP2020-48 |
In the corneal reflection method, the user is asked to gaze at a number of calibration points whose visual angles are kn... [more] |
HIP2020-48 pp.81-84 |
WPT, EE (Joint) |
2020-10-07 15:05 |
Online |
Online |
Measurement Method of High-Frequency-Voltage/Current Waveforms using Directional Coupler and its Calibration Takuma Nakae, Hiroshi Hirayama (NIT) WPT2020-22 |
This report proposes a measurement method of voltage/current waveform assuming applications of wireless power transfer(W... [more] |
WPT2020-22 pp.18-23 |
EMCJ |
2020-07-02 13:25 |
Online |
Online |
An Analysis on Main Uncertainty Factors of System Validation and Probe Calibration for SAR Measurement Yuto Shimizu (NICT), Nozomu Ishii (NICT/Niigata Univ.), Tomoaki Nagaoka, Kanako Wake, Soichi Watanabe (NICT) EMCJ2020-11 |
The specific absorption rate (SAR) is used for an assessment of a human exposure from wireless communication devices. Wi... [more] |
EMCJ2020-11 pp.1-5 |
PRMU, IPSJ-CVIM |
2020-03-16 14:40 |
Kyoto |
(Cancelled but technical report was issued) |
Projector Calibration using a Pinhole Mask Plate Masatoki Sugimoto, Daisuke Iwai, Kosuke Sato (Osaka Univ.) PRMU2019-76 |
Although many projector calibration methods exist, most of them have same problem: depend on the
size of the target or ... [more] |
PRMU2019-76 pp.59-64 |
IBISML |
2020-03-11 10:45 |
Kyoto |
Kyoto University (Cancelled but technical report was issued) |
Calibrated Surrogate Maximization of Linear-Fractional Utility in Binary Classification Han Bao (Univ. of Tokyo/RIKEN), Masashi Sugiyama (RIKEN/Univ. of Tokyo) IBISML2019-43 |
Complex classification performance metrics such as the F-measure and Jaccard index are often used to handle class imbala... [more] |
IBISML2019-43 pp.71-78 |
ITS, IEE-ITS |
2020-03-10 17:50 |
Shiga |
Ritsumeikan Univ. (BKC) (Cancelled but technical report was issued) |
A study on three-dimensional reconstruction using a scanning laser range finder and a spherical camera Kou Yamasaki, Yasushi Tauchi, Yoshiki Mizukami (Yamaguchi Univ.) ITS2019-72 |
In this study, we attempt to reconstruct a 3D structure by synthesizing 3D point cloud obtained with a combination of a ... [more] |
ITS2019-72 pp.105-110 |
CS, CAS |
2020-02-27 11:20 |
Kumamoto |
|
Modeling and verification of power loss at curvature roads of EV driving Haruya Fujii, Kazuki Kuraya, Lei Lin, Masahiro Fukui (Ritsumeikan Univ.) CAS2019-103 CS2019-103 |
(To be available after the conference date) [more] |
CAS2019-103 CS2019-103 pp.31-36 |
PRMU |
2019-12-20 14:45 |
Oita |
|
Non-Orthogonal Cross Point Detection with Function and Numerical Models Nobuhiko Wakai (Panasonic), Takeo Azuma (OmniVision Technologies) PRMU2019-60 |
This paper studies non-orthogonal cross point detection problem for a fish-eye camera calibration. We suggest that cross... [more] |
PRMU2019-60 pp.87-92 |
EMCJ, IEE-EMC |
2019-12-13 14:25 |
Aichi |
Chukyo University |
A design on a matching section of a waveguide for a SAR probe calibration Yuto Shimizu (NICT), Nozomu Ishii (NICT/Niigata Univ.), Tomoaki Nagaoka, Kanako Wake, Soichi Watanabe (NICT) EMCJ2019-77 |
In a compliance test of wireless communication devices, a head or a flat phantom filled with a human tissue equivalent l... [more] |
EMCJ2019-77 pp.13-18 |
SANE |
2019-11-29 11:15 |
Osaka |
OIT UMEDA Campus |
RCS Calibration for Near-Field to Far-Field Transformation Shun-ichi Takaoka (NTUT), Hirokazu Kobayashi (OIT), Yang-Lang Chang, Chih-Yuen Chu (NTUT) SANE2019-79 |
The imaged based Near-Field to Far-Field Transformation(NFFFT) method for RCS measurement enables to evaluate Far-field ... [more] |
SANE2019-79 pp.49-53 |
PEM (Workshop) |
2019-11-18 - 2019-11-19 |
Mie |
Sinfonia Technology Hibiki Hall Ise (Ise Tourism and Culture Hall) |
Calibration of an Optical Electric-Field Probe at Frequencies Below 30 MHz Using a Shortened Monopole Antenna Jerdvisanop Chakarothai, Katsumi Fujii, Kanako Wake, Soichi Watanabe (NICT) |
There is an increasing use of devices using electromagnetic fields at intermediate frequencies (300 Hz – 10 MHz) s... [more] |
|
CCS |
2019-11-14 13:25 |
Hyogo |
Kobe Univ. |
Calibration of Confidence in Deep Learning under Dataset Shift Kazuki Yoshida, Takashi Matsubara, Kuniaki Uehara (Kobe Univ.) CCS2019-25 |
Calibration of confidence is important when you want to obtain not only the prediction class of unknown data but also th... [more] |
CCS2019-25 pp.5-8 |
SDM |
2019-11-08 14:30 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
[Invited Talk]
Investigation of TCAD Calibration Methods for Saturation and Tail Current of 6.5kV IGBTs Takeshi Suwa, Shigeaki Hayase (TDSC) SDM2019-78 |
In this work we focus on two calibration methods to clarify a key point of TCAD calibration for turn-off waveforms and I... [more] |
SDM2019-78 pp.49-54 |
SR |
2019-11-05 10:50 |
Overseas |
Rutgers University Inn & Conference Center, NJ, USA |
[Poster Presentation]
Channel Assignment and Differential Data Transmission in Physical Wireless Parameter Conversion Sensor Network Akinori Kamio, Osamu Takyu (Shinshu Univ.), Takeo Fujii (UEC), Mai Ohta (Fukuoka Univ.) SR2019-80 |
This paper proposes the channel assignment and the differential data transmission for physical wireless parameter conver... [more] |
SR2019-80 pp.43-44 |
HIP |
2019-10-31 15:10 |
Kyoto |
Kyoto Terrsa |
Simple measurement of eye movements using a camera mounted on a temple of glasses Shinichi Hikita, Shingo Hashida (Osaka Electro-Communication Univ.) HIP2019-62 |
A wearable eye-tracker is possible to enable human-robot communication with gaze gestures in daily life. The conventiona... [more] |
HIP2019-62 pp.71-73 |
WPT, EE (Joint) |
2019-10-10 15:20 |
Shiga |
Ryukoku Extension Center, Ryukoku University |
High-power high-frequency impedance measurement for non-linear DUT Takase Ohshima, Hiroshi Hirayama (NIT) WPT2019-43 |
It is necessary to measure impedance of a rectifying circuit to design a matching circuit for wireless power transfer sy... [more] |
WPT2019-43 pp.89-94 |
AP |
2019-08-23 12:10 |
Hokkaido |
Hokkai-Gakuen Univ. |
Study of Direction of Arrival Estimation with Indirect Measurement for Dummy Ports and the Calibration Method Based on an Excitation Condition for an Antenna Array Makoto Higaki, Makoto Sano (Toshiba) AP2019-69 |
We have seen the advent of various wireless communication systems, e.g. cellular system, wireless LAN, Bluetooth®, RFID ... [more] |
AP2019-69 pp.117-122 |
SDM, ICD, ITE-IST [detail] |
2019-08-09 11:35 |
Hokkaido |
Hokkaido Univ., Graduate School /Faculty of Information Science and |
Interface with Opamp Output-Impedance Calibration Technique for a Large Integrated 2-D Resistive Sensor Array Yohsuke Shiiki, Hiroki Ishikuro (Keio Univ.) SDM2019-48 ICD2019-13 |
In this paper, a noble gas sensing system usjing a large scale integrated resistive sensor array and its interface syste... [more] |
SDM2019-48 ICD2019-13 pp.73-78 |
MSS, CAS, SIP, VLD |
2019-07-31 16:20 |
Iwate |
Iwate Univ. |
Measurement method of skin deformation that worked on machine learning Ken Sekiguthi, Takahiko Mori (Shonan Institute of Tech.) CAS2019-21 VLD2019-27 SIP2019-37 MSS2019-21 |
payment rate is significantly lower than in Europe and the United States where the public payment
system is in place. I... [more] |
CAS2019-21 VLD2019-27 SIP2019-37 MSS2019-21 pp.95-97 |
EMCJ, EMD, WPT, PEM (Joint) [detail] |
2019-07-19 11:50 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
Calibration of Optical Electric-Field Probe in Liquid Phantom Using Sheathed Dipole Antenna Jerdvisanop Chakarothai (NICT), Nozomu Ishii (Niigata Univ.), Kanako Wake, Katsumi Fujii, Soichi Watanabe (NICT) |
In order to check compliance for MHz-band wireless power transfer systems, we have proposed a calibration method for ele... [more] |
|