Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
MW |
2021-03-05 14:30 |
Online |
Online |
Design of Metamaterial Inspired Transmitter for Misalignment Insensitive Wireless Power Transfer System through Biological Tissues Takashi Miyamoto, Ramesh Pokharel, Kuniaki Yoshtomi, Adel Barakat, Shimaa Alshhawy, Jiang Xin (Kyushu Univ.) MW2020-97 |
Conventional resonant inductive coupling wireless power transfer (WPT) systems encounter performance degradation while e... [more] |
MW2020-97 pp.33-38 |
MW, EST, OPE, MWP, EMT, IEE-EMT, THz [detail] |
2019-07-19 10:00 |
Hokkaido |
Hakodate City Central Library |
A Study on Development of Phantom for Pseudo-Electrocardiogram Tatsuhito Nakane, Shiho Sakamoto, Takahiro Ito (NITech), Nobuaki Matsuura, Hiroyoshi Togo (NTT), Akimasa Hirata (NITech) EMT2019-33 MW2019-46 OPE2019-37 EST2019-35 MWP2019-33 |
In recent years, many wearable devices have been developed for the purpose of health management in daily life according ... [more] |
EMT2019-33 MW2019-46 OPE2019-37 EST2019-35 MWP2019-33 pp.155-160 |
MBE |
2019-06-21 14:15 |
Hokkaido |
|
Influence of coherence length on scattering suppression by digital phase-conjugate light Sogo Toda (NIT, Ishikawa), Yuji Kato (Hokkaido Univ.), Koichi Shimizu (Waseda Univ.) MBE2019-18 |
The strong scattering in biological tissue is a difficult problem for optical imaging and measurement of an animal body.... [more] |
MBE2019-18 pp.11-15 |
EMCJ, WPT (Joint) |
2018-06-15 09:30 |
Nagasaki |
|
Maiking and evaluation of biological equivalent phantoms for microwave radar Horiguchi Genki, Akiyama Kousuke, Tanaka Toshiyuki, Fujimoto Takafumi (Nagasaki Univ) EMCJ2018-14 |
In the development of medical equipment using electromagnetic wave radar, the biological equivalent phantom must be used... [more] |
EMCJ2018-14 pp.17-22 |
AP |
2017-12-14 13:00 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
Propagation Simulation of Broadband Electromagnetic Pulse inside Biological Bodies Jerdvisanop Chakarothai, Kanako Wake, Soichi Watanabe (NICT) AP2017-147 |
In order to analyze wave propagation of a broadband EM pulse inside biological bodies, it is necessary to consider frequ... [more] |
AP2017-147 pp.7-12 |
EMCJ, IEE-EMC |
2016-12-16 11:20 |
Aichi |
Nagoya Institute of Technology |
Non-contact Measurement of the Dielectric Properties of Biological Tissues at 100 - 1000 kHz
-- Simulation Using an Equivalent Circuit -- Shiro Kawai, Kenji Shiba (TUS) EMCJ2016-101 |
The recent development of techniques such as wireless power transfer has led to increasing concerns about adverse effect... [more] |
EMCJ2016-101 pp.13-18 |
US |
2016-05-23 14:20 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
Effect on giant cluster-like vesicles by an ultrasonically activated device Ryosuke Yahagi, Kenji Yoshida, Yiting Zhang, Masahiko Ebata, Tadashi Yamaguchi, Hideki Hayashi (Chiba Univ.) US2016-14 |
This paper proposes a technique for destroying a tissue marker composed of giant cluster-like vesicles (GCVs). GCVs encl... [more] |
US2016-14 pp.13-18 |
MBE, NC (Joint) |
2016-03-23 09:50 |
Tokyo |
Tamagawa University |
Fundamental study for transillumination imaging of biological body using digital phase-conjugate optics Sogo Toda, Yuji Kato, Koichi Shimizu (Hokkaido Univ.) MBE2015-118 |
In transillumination imaging of an animal body, the light scattering in the biological tissue is the serious problem of ... [more] |
MBE2015-118 pp.83-88 |
AP (2nd) |
2016-03-01 14:50 |
Overseas |
Telecommunications University, Nha Trang, Vietnam |
High accuracy temperature analysis of biological tissue in microwave coagulation therapy Yuta Endo, Kazuyuki Saito, Koichi Ito (Chiba Univ.) |
In this study, to obtain a more accurate analysis of the temperature in microwave coagulation therapy (MCT) for liver ca... [more] |
|
MI |
2016-01-19 14:05 |
Okinawa |
Bunka Tenbusu Kan |
[Special Talk]
Development of retinal OCT system and its clinical application in ophthalmology Masahiro Akiba (Topcon/Riken) MI2015-97 |
Optical coherence tomography (OCT) is a widely known cross-sectional imaging modality which performs micrometer-scale, c... [more] |
MI2015-97 pp.113-116 |
MW |
2015-12-17 13:25 |
Tokyo |
Tokyo Univ. of Science |
Development and Evaluation of Dry-Phantom for Cancer Therapy Yuki Ito, Tetsuyuki Michiyama, Shuzo Kuwano (Nihon Univ.) MW2015-138 |
The cancer coagulation therapy using microwave energy radiated by an antenna is a simple and minimally invasive. The imp... [more] |
MW2015-138 pp.31-34 |
EMCJ, IEE-EMC |
2014-12-19 11:15 |
Shizuoka |
Shizuoka Univ. |
Dielectric properties measurement of biological samples using high speed sampling at frequencies below 1 MHz Hiroyuki Nedate (Aoyama Gakuin Univ./NICT), Kanako Wake, Kensuke Sasaki, Katsumi Fujii, Soichi Watanabe (NICT), Ryosuke Suga, Osamu Hashimoto (Aoyama Gakuin Univ.) EMCJ2014-78 |
Dielectric properties of biological tissues are necessary to understand interaction between biological body and electrom... [more] |
EMCJ2014-78 pp.25-30 |
MBE |
2013-10-10 15:15 |
Osaka |
Osaka Electro-Communication University |
Biological tissues imaging with phase-contrast microscope based on active image processing method Yasuhiro Miyake, Masaki Hisaka, Takashi Ikuta (Osaka Electro-Communication Univ.) MBE2013-65 |
Phase-contrast imaging is useful technique in observing the refractive index structure of biological tissue cells. We pr... [more] |
MBE2013-65 pp.31-33 |
AP (2nd) |
2012-12-21 10:00 |
Okinawa |
KDDI Naha Building 6F |
Fundamental study on measurement of dielectric properties of biological tissue-equivalent phantoms in the HF band Ryotaro Suga, Kazuyuki Saito, Masaharu Takahashi, Mizuki Inoue, Koichi Ito (Chiba Univ.) |
In recent years, radiofrequency devices, which are usually placed in the vicinity of the human body, are widely used. In... [more] |
|
MBE |
2012-07-13 15:45 |
Okayama |
Okayama University |
Investigation of electrode arrangement for the bio impedance measurement of tumor tissue Seiji Iwami, Masatake Akutagawa, Takahiro Emoto, Shinsuke Konaka, Yohsuke Kinouchi, Tadaoki Morimoto, Akira Tangoku (Tokushima Univ.), Kenji Okazaki (Kunitomi Hospital), Emiko Yasuno (Anan National College of Technology), Takuto Inoko, Tomoya Takahashi (Tokushima Univ.) MBE2012-28 |
Electrical resistance of normal tissue is different to electrical resistance of malignant tissue that is known by past s... [more] |
MBE2012-28 pp.25-29 |
AP |
2010-05-13 10:25 |
Overseas |
Southeast Univ. |
Characteristics of Loop Antennas Closely-Placed to Different Arm Models Yumiko Uno, Kazuyuki Saito, Masaharu Takahashi, Koichi Ito (Chiba Univ.) AP2010-13 |
The consideration of the interaction between the antenna and the human body is important in the design of the antenna us... [more] |
AP2010-13 pp.7-10 |
AP |
2009-03-10 09:50 |
Overseas |
University of Macau |
Characteristics of Antennas Closely-Placed to Different arm Models Yumiko Uno, Kazuyuki Saito, Masaharu Takahashi, Koichi Ito (Chiba Univ.) AP2008-224 |
The consideration of the interaction between the antenna and the human body is important in the design of the antenna us... [more] |
AP2008-224 pp.63-66 |
AP |
2008-10-16 16:05 |
Miyagi |
Tohoku Gakuin University |
Dependence on characteristics of closely-placed antenna by arm structure Yumiko Uno, Kazuyuki Saito, Masaharu Takahashi, Koichi Ito (Chiba Univ.) AP2008-101 |
The consideration of the interaction with the human body is important in the design of the antenna used for the equipmen... [more] |
AP2008-101 pp.39-42 |
EMD |
2008-03-07 16:35 |
Tokyo |
|
Suppression of near-surface sensitivity for diffuse reflective optical tomography Shinnosuke Imaizumi, Takuya Iizuka (TMCAT), Keiko Fukuda (TMCIT) EMD2007-136 |
We proposed a method for suppressing the near-surface sensitivity to improve the measurement accuracy of oxygen consumpt... [more] |
EMD2007-136 pp.49-52 |
EMT, LQE, OPE, PN |
2008-01-28 09:30 |
Osaka |
|
Analysis of optical scattering in ultrasound-modulated optical tomography Masaki Hisaka, Yu Sasakura (Osaka Electro-Communication Univ.) PN2007-37 OPE2007-145 LQE2007-123 |
A biological tissue sample with some fibrotic tendons and a stained section of the tissue with the same acoustic impedan... [more] |
PN2007-37 OPE2007-145 LQE2007-123 pp.1-4 |